22nd February 1941, Page: 260, Column: 1 Old Documents Re-Examined — VITheory and Practice 50 years agoCircuit Breakers. Continuing the examination of some of the documents "on the shelf" the appended notes were considered of sufficient interest to reproduce. A circuit breaker may be briefly described as an automatic switch on which a device is attached, mechanically and electrically arranged, so as to operate and open the switch when any particular point, which will be a source of danger to the electrical apparatus under its control, is reached. The "danger point" arises, as experience has so often proved, not so much on account of faults in the electrical apparatus, but through accidents and other causes happening to the machinery which the electrical apparatus is either driving or being driven by. It will, therefore, be seen that the use of circuit breakers not only affords protection to the machinery or apparatus, electrical or mechanical, but secures a policy of insurance as well on both the driving and driven machinery which is invariably of far greater monetary value. There are many types of circuit breakers in general use for ordinary and special purposes, some arranged for electrical and some for thermal control. They may be enumerated as follows :— Overload. — To protect against "overload" and "short circuit." No Voltage. — To disconnect motors, etc., should supply fail from any cause. Underload. — For storage batteries, to prevent the reversal of current from them into the generators. Reverse Current. — For generators in parallel, to protect any one generator against the others reversing into it. This type of circuit breaker is designed to break the circuit in the event of a change in the direction of the current. This design is now an established necessity when running generators in parallel. It protects each and all against the probability of the remainder dangerously reversing into any one generator should anything happen to interfere with its proper working. It also operates when taking a generator out of circuit. Overload and No Voltage. — To protect motors from overload, and also to disconnect them should the supply fail. Overload and Underload. — To protect storage batteries from "overload" and reversal of current from them into the generators. Overload and Reverse. — To protect generators in parallel from overload, and any one generator against any other or others reversing into it. Circuit breakers may be of the single, double, or triple-pole type, and with either thermal or magnetic release. In the double-pole and triple-pole patterns makers usually prefer to connect the switches in tandem. Triple-pole circuit breakers are usually fitted with two coils and tripping devices otdy, each mechanism opening the three switches. In the double-pole and triple-pole types, the operating mechanism may have the same or different functions. For example, Messrs. Crompton supply a circuit breaker with an overload release on one pole, and a reverse current release on the other, and they can also supply another pattern having both an overload and reverse current release on each. Circuit breakers with thermal attachment can only be supplied with overload releases. In the Crompton circuit breaker the main switch consists of a laminated copper brush, carried by, but insulated from, a metal carrier. The brush moves in a vertical direction, making contact with two massive gun-metal blocks. There are three sets of breaking contacts and brushes, viz. : (1) The main brush, which leaves the contacts first. (2) An auxiliary set of carbon brushes in parallel with, but opening after, the main brush ; they prevent any sparking on the main brushes. (3) A set of supplementary contacts, also in parallel with the main and auxiliary brushes, but so arranged that the final break takes place in a strong magnetic field. All the brushes on the main and auxiliary contacts have a double break. To close the circuit the handle is raised, and by means of a roller catch it lifts the centre spindle carrying the brush. The brush travels upwards until two catches fixed to the brush carrier engage with stops provided on the bracket. This arrests the brush, and a further movement of the handle compresses a spring attached to the brush spindle. At the end of its travel the handle disengages the catches which are holding the brush, and the spring drives the brush on to the contacts. When the switch is closed, the handle is in an "upright" position, and can then be opened either by hand or by the automatic release, when the handle falls to the "downward" position. When the instrument opens automatically, the operating mechanism acts on a lever which liberates a weight arranged immediately above the roller catch. This weight in falling releases the roller catch, and opens the switch. When switching off by hand the handle is moved downwards, releasing the roller catch, the break being accelerated by a spring. It is advisable under certain conditions to suspend the automatic function of a circuit breaker, and for this purpose a special hold-off attachment can be fitted to the operating mechanism. Alternating Current. "When," Slingo and Brooker said in their text-book on Electrical Engineering, "it is desired to convey energy to a distance by means of electricity, either for the purpose of light or mechanical motion, the chief problem to be faced is, how to reduce to a minimum the waste of energy during the transmission. We have seen that when a wire is used to convey a current, the rate at which energy is lost in that wire can be measured by multiplying together the current strength in amperes and the difference of potential between the ends of the wires in volts, the result being the number of watts so expended. And since the potential difference is equal to the product of the resistance of the wire and the current flowing, the loss in watts may also be calculated as the product of the resistance and the square of the current strength. That is to say, in the first place the power expended in any part of a circuit is proportional to the resistance of that part. Suppose, for example, a dynamo was employed to furnish current to a number of lamps arranged in parallel, their joint resistance being 10 ohms ; then, if the resistance of the machine and leads or connecting wires was also 10 ohms, exactly as much power would be wasted as would be usefully expended in the lamps, a state of affairs which manifestly could not be tolerated. If the resistance of the machine and leads was reduced to 1 ohm, then the power wasted would be one-tenth of that usefully employed, and so on. "The resistance of the combination to which power has to be supplied is, as a rule, extremely low ; and when the lamps or motors are joined in parallel, the current carried by the mains is equal to the sum of that required by the whole of them. Consequently, the resistance of these mains must be kept extremely low, a small fraction of an ohm in fact, otherwise the proportion which the power wasted bears to the total quantity of power developed becomes excessive. To keep the resistance low, copper of high conductivity must always be employed, but the practical limit as regards sectional area is quickly reached on account of the high price of that metal. Speaking generally, it may be said that transmission of energy to any considerable distance by electricity is not economical, if we depend upon the reduction of waste, merely by increasing the conductivity of the leads. Again, stating the case as Watts lost = C2R, where R is the combined resistance of the leads and generator, we see that the only way out of the difficulty is to reduce the current strength." Before the introduction of the three-wire direct current system high pressure alternating currents were almost invariably employed for the transmission and distribution of electrical energy in towns and cities. Present practice inclines to a combination of the two systems under special conditions. Let us, however, confine ourselves to the consideration of the efficiency of high pressure alternating currents when the distances to which electrical energy has to be transmitted are comparatively great. Neglecting the consideration of the three-wire system, let us endeavour to place before ourselves as clearly and concisely as possible the considerations which would influence us in employing either a direct current two-wire or an alternating current system under certain specified conditions. In the two-wire system, it must be borne in mind the E.M.P. must not exceed 250 volts if the scheme includes the parallel lighting of ordinary incandescent lamps. It is true that the introduction of motor generators would at once solve the question of the practicability of employing higher pressures, but they would do it at the cost of reduced efficiency, increased complexity, and the necessity of providing separate lighting mains. If we were called upon to design a system of power transmission for 1,000 horse-power to a distance of, say, 5 miles from point to point, and we were at liberty to select a direct current system of 250 volts or an alternating current system of 10,000 volts, we should not hesitate for one moment in our selection of system, since the size of cable depends upon the current strength in amperes. At 250 volts direct we should, even when eliminating voltage drop in the conductors, have to provide a lead and return cable for approximately 3,000 amperes ; for the alternating system, say 80 amperes, and this at once decides matters. But, it will be asked, since the direct current system is for practical purposes confined to 250 volts for lighting and power combined, and 500 volts for power alone, how is it that 10,000 volts can be employed for any combination with the alternating current system ? The answer is : By means of transformers. (To be continued.)
|
|||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||