5th October 1940, Page: 105, Column: 2
Superheated Steam
Of the source of waste in an engine the condensation of steam from the cooling
effects of the cylinder walls, or cylinder condensation as it is called, is by
far the greatest. This was recognised even early in the last century, but in
1855, for the first time, the extent of this loss was established in a definite
manner by Hirn. It has been established, practically, that in an
ordinary single cylinder non-condensing engine the amount of waste through
cylinder condensation amounts, with an early cut-off, to from 35 to 40 per
cent. of the total steam used. The best means of partially or wholly preventing
this loss is by the use of superheated steam.
Steam is said to be superheated when, at any given boiler pressure, it has a
higher temperature than the water from which it was evaporated. Moisture, no
matter from what cause arising, cannot exist in the presence of superheated
steam ; it robs the steam of its extra heat, and is itself evaporated into
steam. The temperature of saturated steam cannot be raised without increasing
its pressure ; but the temperature of superheated steam allowed to expand can
be raised without increasing the pressure. Expansion is provided for by the
steam being drawn off and used, or, if no steam is used, by the safety valve
lifting.
The "rationale" of the use of superheated steam is not only the
prevention of loss through condensation in steam pipes, but the addition of
such an amount of superheat in the steam before it enters the cylinder as will
make up for that robbed by the cylinder walls, so that the steam will remain
practically dry, at all events up to the point of cut-off.
The principle on which a superheater should be constructed to give a
sufficiently high temperature are :—
Firstly : The necessity of placing the superheater in a position where a
suitable temperature is available. If a boiler is working under economical
conditions the difference between the temperature of saturated steam, and of
the escaping flue gases leaving a boiler, is not sufficient to superheat the
steam produced unless the surface of the superheater be very large ; hence,
generally speaking, a superheater should not be placed in the flue between
boiler and chimney. On the other hand, if placed too near the boiler furnace,
possibly damage would result from the impact of flame.
Secondly : The superheater should be constructed to admit of all its
parts expanding and contracting freely, without severe strains being put on any
of the joints, which might cause them to leak ; flanged joints, when exposed to
furnace gases, should be avoided wherever possible.
Thirdly : Provision should be made to protect the superheater against
overheating when steam is not, passing through it sufficiently to carry away
the heat supplied by the furnace gases.
Experience has led to the following conditions to which the construction of an
independently fired, or "separate furnace" superheater should conform
:—
(1) It should be made entirely of wrought steel, with tubes small in diameter,
seamless, and thick.
(2) No perishable packing, such as asbestos, should be used for any joints.
(3) The steam should be circulated rapidly.
(4) The areas through which the steam passes should be considerably in excess
of the steam inlet and outlet connections to avoid drop in pressure.
(5) The tubes should not be subjected to the direct impact of the furnace
gases, but should be in a chamber filled evenly with Completely burnt gases of
as low a temperature as practical to ensure the final superheat required.
(6) It follows that a large heating surface and a low rate of heat transmission
should be provided, say about 2,200 B.T.U. per square foot of surface per hour.
(7) The entire construction should offer the greatest freedom or expansion and
contraction.
 |
 |
|
Names mentioned in this article
|
 |
 |
| Name | Age | Occupation | Notes |
| Hirn, — | | | |