Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

5th October 1940, Page: 101, Column: 1

Fireproofing Mine Shafts

This is the subject dealt with by Mr. Jos. R. Guiteras in Information Circular 7075 of the U.S. Bureau of Mines. He says that fireproofing a mine shaft implies lining the shaft with fireproof material or rendering fireproof the materials already composing the shaft lining. Reference is made to the procedure followed by Anaconda and other mining companies in carrying out their fire-prevention programmes, the standard applications of fireproof construction including the use of (1) steel shaft sets, (2) precast reinforced concrete shaft sets, (3) concrete rings, (4) continuous concrete lining, and (5) gunite.

Steel Shaft Sets. — Steel sets are of structural shapes. Wall plates, end plates, and dividers usually are H-sections with the flanges vertical. Posts are made of angles. Guides usually are made of wood but sometimes are of steel; safety dogs on cages get a better grip on wooden guides. As much of the set as possible is shop-riveted ; the rest is bolted in place. Steel sets sometimes are coated with gunite, poultry wire being used as reinforcement.

Precast Reinforced-Concrete Shaft Sets. — Precast reinforced-concrete sets have members corresponding to those of timber sets, and have been used successfully in both vertical and inclined shafts.

Concrete Rings. — The ring method makes use of a monolithic concrete lining in horizontal bands separated by intervals of bare rock.

Continuous Concrete Lining. — This type of lining usually is poured to rock but sometimes is formed in the clear and anchored at intervals, in which case the intervening space may be backfilled. Concrete mixtures ordinarily used range from 1:2:4 to 1:3:6, and the thickness ranges from 8 to 18 inches. The lining usually is placed from the bottom upward, but there may be several points of attack to keep the crew busy. Mixing usually is done at the surface, especially on large jobs ; it sometimes is done underground. Reinforcement of lining usually consists of ½- or ¾-inch bars, either round or square. The horizontal bars are spaced 6 to 9 inches apart; the vertical bars, about 24 inches apart. Masonry linings, including concrete blocks, have been used in Europe, but concreting is preferred in the United States.

Gunite. — Gunite is a mixture of sand and cement applied wet under air pressure by means of a cement gun. It may be used to preserve steel or to preserve or fireproof timber. The material to be gunited is covered with wire mesh or expanded-steel lath. Mixtures range from 1 part of cement to 2½ parts of sand to 1:5 at the gun. One bag of cement yields 32 square feet of a 1:4½ mixture or 22 square feet of a 1:3 mixture, 1 inch thick. Sand should be minus ¼ inch. The usual sizes of gun require 110 to 225 cubic feet of free air per minute at 40 to 75 pounds per square inch pressure.

In the summary of fireproofing measures recommended as a result of lessons that have been learned Mr. Guiteras includes—

The safest surface construction is a steel headframe with a steel and concrete shaft collar to a depth of 25 feet.

Surface structures near a shaft should be of incombustible material or fireproofed and protected by a sprinkler system; otherwise, surface structures should be at least 100 feet from the shaft.

A steel door should be placed at the shaft collar.

All shafts, stations, landings, and shaft bottoms should be lined with fireproof material. It is more important to fireproof shaft bottoms and landings than the shaft itself. If a mine has a long life, concreting may not be an additional expense. Downcast shafts often are dry and should be lined with concrete. If shifting ground makes a concrete lining impractical, the timbered shaft should be fireproofed with gunite.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Guiteras, Joseph R.    U.S. Bureau of Mines  


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print