20th April 1940, Page: 323, Column: 2
Advantages Of Turbine Pump
In his paper on Turbine Pumps in the ANNUAL MAGAZINE of
the Notts. Mining Students' Association Mr. D. Harper lists the
advantages of the turbine as follows :—
(1) The turbine pump because of its simple design is comparatively cheap.
(2) The cost of installation is smaller because the small overall
dimensions reduce the amount of excavation necessary.
(3) The load can be applied gradually by use of the gate valve.
(4) The frictional resistance is small.
(5) There are only two glands in a turbine pump and so the
resistance due to this cause is minimised. The packing glands
require little attention except for an occasional tightening of the
gland nuts, and renewal is only necessary every three months.
(6) The turbine pump is probably the most efficient type of
pump, a good overall efficiency being in the region of 70 per cent.
This is largely due to the fact that the pump is usually driven
direct.
(7) Maintenance of turbine pumps is easy, and they can be
readily converted to deliver against varying heads.
(8) They are also reliable, and cases of pumps running
continuously for years without any serious reduction in efficiency
are common.
Points that should be observed when centrifugal pumps are
put into service are stated thus :—
(1) In order to avoid unnecessary friction and development
of heat, the packing should not ho pressed too tightly by the
gland; a little water should drip out continuously.
(2) The oil wells of ring lubricated hearings should be carefully
cleaned and filled to the correct level with the appropriate oil.
(3) The pump is primed by opening the air cock, and by-passing
water past the non-return valve. The pump is primed when
water appears at the air cocks, which are then closed.
(4) When the pump has been primed the by-pass should he
left open whilst starting the pump. After the pump has started
delivering water the by-pass valve should be closed.
(5) When a pump has been out of service for some time it
should be rotated by hand to ensure that it runs easily, and care
must be taken never to run a centrifugal pump without water
in it.
(6) The pump should be started with the gate valve closed
and the gauges carefully watched. The pressure should rise
steadily as the speed increases, and if it does not do so, it may
be assumed that there is air in the pump and priming must be
carefully repeated. The pump is then run up to full speed and
the gate valve slowly opened until normal working conditions
are reached. Should the ammeter show that the motor is fully
loaded before the full delivery is obtained, the motor should be
shut off or overheating may occur.
(7) The valve in the by-pass pipe is closed when normal
working conditions are reached. The object of keeping the
by-pass valve open during starting is to permit a small quantity
of water to circulate, thereby preventing heating of the pump.
(8) To stop a pump the regulating valve must first be closed
before tripping the switch.
(9) Should the speed of the pump fall so that delivery ceases,
the plant should be shut down until normal speeds may be
obtained.
The following points should also be observed: (e) Whilst the
pump is running, regular observations of the pump gauge should
he made. (b) The packing material should always be in good
condition, so that the air seal is maintained. It should be renewed
when necessary and the gland nuts tightened occasionally.
(c) The valves and strainer must be kept clean. (d) When the
pump is out of commission the internal parts must be protected
from rust, and all water must be drawn from the pipes and pump
in frosty weather.
 |
 |
|
Names mentioned in this article
|
 |
 |
| Name | Age | Occupation | Notes |
| Harper, D. | | | |