Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

23rd March 1940, Page: 298, Column: 1

Firedamp

By Supt. F. J. Johnston, M.I.M.E, of the Durham and Northumberland Collieries Fire and Rescue Brigade.

Extracts from paper read before the Associates and Students' Section of the North of England Institute of Mining and Mechanical Engineers.

Early History.

Until the year 1776 no distinction was drawn between "inflammable airs" from different sources. In that year Volta discovered that the gas issuing from marshes (marsh gas) differed from that obtained by the acids on metals (hydrogen), in that it required four times as much oxygen for combustion and yielded carbon dioxide gas and water as a result thereof.

In the year 1805 Dr. Henry of Manchester proved that the gases obtained by the distillation of coal contained two distinct gases — light carburetted hydrogen and a heavy carburetted hydrogen.

The name of methane was given to marsh gas by one Hoffman at a much later date.

In 1807 John Dalton of Manchester studied closely the composition of the carburetted hydrogens. It was here that he first got his ideas of the atomic theory.

In 1815 to 1819 Sir Humphry Davy carried out researches on flame in response to an appeal from the Sunderland Society for the Prevention of Accidents in Coal Mines, in consequence of a disastrous explosion on 25th May, 1812, at Felling Colliery, involving the loss of 92 lives. The direct outcome of these experiments was the invention of the miner's safety-lamp ; they also greatly extended our knowledge of flame and explosions and can be rightly regarded as having laid the foundations of all subsequent investigation on the subject. From his experiments he deduced that a certain heat was required for the ignition of the gas, and that unless that heat is passed on continuously from one layer of gas to the next there cannot be continuous propagation of the flame through it. Hence he concluded that by sufficiently cooling the explosive mixture it should be possible to prevent the passage of flame. We all know how he came to use the wire gauze after trying narrow tubes and layers of metal.

Chemical Composition and Properties.

Firedamp is the name given to mixtures of methane and air found in the air of coal mines. It has the same chemical composition as marsh gas, which is found exuding from decaying carbonaceous matter in marshy ground.

Methane is the first of the hydrocarbons known as the paraffin series. Other compounds of the series are ethane, propane, butane, etc.

The gas is colourless, tasteless, and odourless, although some miners aver that they can detect the gas by its smell. This smell, when present, is due to the admixture of small quantities of the higher hydrocarbons such as ethane, etc. It is lighter than air, its specific gravity being 0.559. Methane is not a toxic gas, and is one of the few gases which are physiologically inert such as nitrogen and hydrogen. If the 79 per cent. of nitrogen at present in the air we breathe were replaced by 79 per cent. methane there would be deleterious effects. In practice in mines, however, where there are high percentages of methane there will be deficiency of oxygen, and therein lies a great danger to respiration.

The most important property of methane is its explosive property or inflammability. It has an explosive range of between 5 per cent. and 15 per cent. ; the most explosive point or the point where perfect combustion takes place is somewhere about 95 per cent.

The minimum ignition temperature of mixtures of firedamp and air is about 510°C. If out of contact with a heated surface it lies between 650 and 750°C.

If the gas is previously heated, such as passing through heated strata, the mixture is more easily ignited and will explode feebly at a lower percentage, somewhere about 3.5 per cent. This is important when dealing with gob-fires. Further, the minimum ignition temperature under such conditions is obtained between 7 and 8 per cent. and not at 9.5 per cent. which is the mixture for complete combustion. An interval of time elapses, known as the "ignition lag," between the instant the inflammable mixture attains the ignition temperature and the presence of flame. The lag is quite appreciable, and in some cases amounts to several seconds.

Where a fire exists in a gassy mine great care must be taken to prevent the combination of factors which might cause an explosion. By knowing the factors of pressure and temperature, and taking analyses on the spot, one is able to tell by reference to the chart whether it is possible to have an explosion or not.

Certain mixtures are capable of forming explosive mixtures if mixed with air. In such cases great care must be taken to see that an excess of air is not admitted. Breathing apparatus have to be worn to allow men to work in such atmospheres. Other mixtures are explosive if the temperature of ignition is present, and such mixtures must be kept clear of fire.

Ignition by Electric Sparks. — There are two kinds of electric spark — inductance sparks and capacity sparks. If an electric spark is analysed it is really found to consist of a series of rapid flashes. The first flash, usually 1/20,000th of a second duration, is succeeded by a series of considerably less bright flashes. A measure of the spark energy may be taken as the value of the primary current. A much lower current is required for ignition by an inductive spark than a capacity spark; also, the most easily ignited mixture is somewhere about 8.3 per cent.

Detection of the Gas.

Firedamp may be detected in percentages up to the lower limits of inflammability (about 5 per cent.) by the appearance of a "cap" or blue halo over the oil flame. The size of the cap varies with a number of factors which should be considered when estimating the percentage of gas present. This is one of the oldest and is still the most reliable and practical method of detection.

In 1812, John Buddle of North of England fame records the effects on a candle flame where a "cap" was shown. Previous to that period (the safety-lamp was not invented until 1815) it is recorded that a pitman could tell by the colour of the sparks from the steel mill what percentages of gas was present. The higher percentage of gas present the more blood red colour the sparks became.

To prevent the luminosity of the oil flame obscuring the pale blue cap of burning gas, the oil flame is lowered until only of an inch is visible. The height of the cap depends upon the size of the wick used and the fuel producing the flame. The larger the wick and the higher the temperature of the flame the higher the cap will he. When using a fuel such as alcohol, benzine or hydrogen gas the height of the cap is much greater than when burning ordinary colza oil.

The wider the wick used the higher the cap will be, and the percentage of gas present may be judged from the basis that when the cap is an equilateral triangle the percentage of gas present is 2½.

Special Detectors.

Several principles have been tried as a means of testing for firedamp. One used is based upon the rate of diffusion of gases of different densities.

The Ansell detector was one of the first on this principle, constructed in the form like an ordinary pocket watch where the percentages can be read off on the dial. The presence of moisture, carbon dioxide and coal dust has effects which tend to render the instrument, inaccurate. Strange to say, the only automatic detector at present approved by the Mines Department is based on this principle — the Ringrose Firedamp Detector.

The Gulliford detector is not accurate in action. In this detector, by means of a switch a platinum filament is heated in the presence of the gas, and the filament fuses when the percentage of firedamp rises to a dangerous proportion. The fuse would then have to be renewed.

Another detector was evolved some time ago which detected firedamp by the difference of sound in air and gas. It was called the firedamp whistle.

In the Leiving detector, the percentage of firedamp is detected by comparing the brightness of two glowing filaments, one of which is enclosed in an airtight vessel while the other is exposed to the atmosphere. By means of two mirrors actuated by a screw on a scale the percentage of firedamp could be read. This appliance was accurate enough, but was clumsy and awkward to carry about.

In the Concordia detector lamp, a small flame lamp burning benzine is attached to the side of an ordinary electric lamp, the benzine lamp being ignited when desired by a filament heated from the battery of the electric lamp.

In the McLuckie detector the principle used in gas analysis is adopted. The gas is burnt on a heated filament. The steam or water vapour formed is allowed to condense and the contraction in volume recorded on a liquid in a U-tube gauge. This is a very accurate and useful instrument — beyond the average pitman's requirements, but may be recommended to colliery managers who have to make analysis in doubtful places.

In the Thornton-Gray lamp the brightness of filaments burning in gas and air is recorded on a small photometric window. In the automatic type the filaments are heated automatically every two minutes, and if firedamp be present at any predetermined figure the electric lamp is extinguished. This is quite an ingenious and simple arrangement and has much to recommend it.

The Leon-Montlucon detector was brought to this country recently from France, and appears quite good. In this we have a Wheatstone Bridge attached to an ordinary electric lamp. Two of the arms of the bridge are exposed to the atmosphere while the other two are sealed. The difference in the resistance of the arms when they are heated can be measured on the ammeter attached. The deviation is practically proportional to the percentage of methane present. The Ceag firm have a detector on the same principle called the Ceag-Montlucon detector.

The M.S.A. detector is an American adaptation of the Wheatstone Bridge idea. It is small and separate from the electric lamp.

The modern tendency seems to favour the simple safety-lamp method, and a small safety-lamp is attached to the electric lamp. The Ceag gas detecting lamp is of this type. The Oldham is of the same type. They are simple and effective.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Dalton, John      
Davy, Humphry, Sir      
Henry, —, Dr.      
Hoffman, —      
Johnston, F. J.    Superintendent  
Volta, —      


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print