10th February 1940, Page: 252, Column: 1
Storage Batteries
The object of a paper on "Storage Batteries : a Review of
their Application," by Mr. E. C. McKinnon, presented for
discussion before the Institution of Electrical Engineers, was to
show the important part played by storage batteries in present
day electrical engineering practice. One brief section of the
paper had reference to mining applications, the Author remarking
that severe restrictions are placed upon the use of storage
batteries in gaseous mines unless there is complete assurance
that no spark can be transmitted to the gases which may possibly
be present. Thus although miners' electric lamps (cap or hand
type) are in general use, storage batteries are not permitted in
connection with battery call systems (bells and signals). In
these the voltage is limited to a maximum permissible of 25 volts,
fed by Leclanche cells. A mixture of methane (firedamp) is
explosive within the limits of 5.6 per cent. and 14.8 per cent.
The presence of quantities even larger than the upper limit has
no narcotic effect. The detection of explosive gases is therefore
all-important, as their presence is not easily shown ; so much so,
that one competent workman in every eight at the long wall
face, and one in every four employed in other working, shall
carry an approved automatic gas alarm. Moreover, such an
apparatus must be used near every electrical motor at the coal
face in safety-lamp mines. The flame safety-lamp is gradually
becoming restricted to use by the deputies and other officials
for showing the presence of firedamp.
Mr. McKinnon proceeds to say that one of the problems for
mining engineers is the best method of firing the fuses attached
to the detonators of explosive charges in non-gaseous mines.
This applies in particular to the Rand gold mines in South Africa,
where reliability is of paramount importance as by law a 24-hour
shut-down is compulsory after a missfire.
In one form of electric igniter, a small but intensely hot spark
is applied to the firing head of the unit from a 4-volt 10-ampere-hour
portable battery. The unit houses an induction coil
arranged with a massively constructed high-speed trembler
mechanism.
Typical electrical tests on this igniter were as follows 6
amperes flowing through the primary, trembler operating at 160
vibrations per sec. battery volts on load, 3.9 volts at coil
terminals, 3.5 ; peak volts (primary), 150 ; peak volts (secondary)
(calc.), 9 150 working spark-gap, 3/32-inch. As regards performance,
when firing consecutively 500 3-inch lengths of fuse 24
to 30 fuses per minute could be fired by one operator. The
duration of the spark operated for each firing was 0.5 sec., and
the total energy taken from the battery to fire 500 fuses was
about 1/20th of its rated capacity.
Use of battery locomotives underground in this country is
permissible, but few have so far been installed.
Concluding this section of his paper Mr. McKinnon says The
demand for better and better lighting has led to the standardisation
of 4-volt lamps in this country. There is also a trend towards
the increased use of cap lamps in preference to the usual hand
lamp design, which was intentionally built to resemble the original
Davy lamp.
 |
 |
|