10th February 1940, Page: 247, Column: 2
Lighting Of Picking Belts
A paper on "Mercury Vapour Lighting on Colliery Picking
Belts" has been read before the South Wales Institute of Engineers
by Mr. C. S. Chubb, M.Sc., of the Mining Department of the
Cardiff University College. The object of the paper was to show
how the removing of dirt on the picking belts can be made more
efficient by the use of this lighting system. The paper constituted
a discussion of general principles, with a survey of particular
installations. The Author said the object of lighting the belt
should be to provide sufficient light, evenly distributed over those
parts of the belt where picking takes place, and in such a way that
there is no glare. The amount of light which may be deemed
sufficient depends upon the colour of the light. As pointed out
light from mercury vapour lamps enhances the visibility of the
dirt particles in coal so that less light is required than if tungsten,
sodium or daylight lamps are used.
The light should be evenly distributed. The pickers must travel
with the belt, and if they station themselves at a bright patch they
will travel into dark patches and much dirt will be missed. Absence
of glare is ensured by the use of reflectors for the lamps. For
low installations set near the belt and in which the lamps are not
greatly above the level of the eye, the wide dispersive type of
reflector can be used effectively and allows the maximum of direct
light to reach the belt. For high installations where the lamps
are well above the eye level, the wide dispersive type of reflector
would expose the discharge tube to the eyes of the workers and
perhaps cause glare. At the same time, the concentrating
reflectors which more closely enshroud the light and reduce glare
also concentrate the light on to the belt and reduce the amount
lost by dispersion on to the floor.
Regarding the spacing of lights Mr. Chubb said that only that
part of the belt where picking takes place need be illuminated.
If dust makes it impossible to use part of the belt, or if for any
reason it is not customary to use parts of the belt, the lamps
should be spaced so as to neglect those parts and to light sufficiently
and evenly those parts which are in use. Again, it is bad policy
to use light on the jib if the belt is inadequately illuminated. If
the dirt gets so far as the jib the belt must be stopped to pick it
and men must clamber down the jib. Better lighting on the belt
would save that happening. If the amount of power which may
be used on the belt has to be restricted it would be better to limit
the length of belt used and to light that adequately, rather than
to dispose the light too widely and achieve general bad illumination.
Mr. Chubb presented notes showing results of installations
surveyed, and in closing offered the following conclusions :—
A ratio of less than 1.25 may be considered satisfactory evidence
of even distribution of light, a ratio of less than 1.15 of satisfactory
spacing of the lamps. A figure of less than 4 watts per square foot
for the effective area of the belt may be deemed a satisfactory
state of power economy.
Results for the average intensity may be obtained with less
labour by only taking readings on the centre line of the belt,
and then plotting a profile as is done on some of the diagrams.
The area of that profile divided by the length should give the
average intensity, and this multiplied by the effective area gives
the total lumens. The results obtained by this method will be
sufficiently accurate for many practical purposes.
 |
 |
|