2nd December 1939, Page: 161, Column: 1
Some Facts About Firedamp
At the November meeting of the Past and Present Mining Students'
Association, held in the Wigan Mining College, Mr. C. S. W. Grice,
of the Safety in Mines Research Laboratories, Sheffield, gave a
most interesting and informative lecture on "Some Facts about
Firedamp" to a large and representative gathering of officials,
workers and students. Mr. O. J. Onions, chairman of the Association,
introduced the lecturer who began by alluding to that
habit of firedamp which is dependent on the fact that bulk for
bulk it is little more than half the weight of air, and because of
its lightness it tends to rise towards the higher places underground.
It was therefore suggested that ascensional ventilation should
always be practised in the ventilation of coal mines in order to
take advantage of the natural tendency of firedamp to seek the
higher parts of the working. He adduced in support of that view
the conclusive experiments which bad been made in the Mining
Laboratories of the College, and which had been verified on the
large scale in the galleries of the Buxton research station.
Sparks and Explosive Gas.
The lecturer then passed to the detection of firedamp by means
of safety-lamps and other forms of firedamp detector. He
expressed the thought that miners had much to be thankful for
in not being troubled with other gases which are more readily
explosive, and more violently explosive, than methane. Emphasis
was laid on the fact that sparks having a greater temperature than
the ignition temperature of methane were sometimes incapable
of igniting firedamp, the explanation given being that hot sparks
must be in contact with the explosive gas for a sufficient time to
enable ignition to take place. The higher the temperature of the
sparks the less is the time lag and vice versa. This was an important
matter in connection with the use of coal-cutting machines
in cutting in bands in which there might be nodules of hard ironstone.
Explosive mixtures of methane and air might be found
in the cut. It had been thought that it would not be possible
to start an inflammation of methane in the undercut of a coal-cutting
machine by means of the sparks emitted from the contact
of the picks with hard rocks, but it had recently been explained
by Allsopp and Wheeler that the requisite condition for the
ignition of methane by a flame had been obtained in the course
of experiments made at the Buxton research station. The
mechanism of ignition was now understood as a result of these
experiments.
Experiments in the Undercut.
Attempts had been made by the use of carbon dioxide inhibitors
to produce a non-combustible mixture of gases in the undercut,
and experiments had shown that the required condition was
obtained by discharging carbon dioxide from the machine into
the undercut at the rate of 1.5 cubic feet per minute. In the
event of machines being used in such circumstances as were likely
to lead to the inflammation of inflammable gas in the undercut
the lecturer pointed to the need for having an adequate supply
of sand or stone dust within easy reach of the persons in charge
of the coal-cutter.
Methane and Sparking.
He expressed the view that methane was a comparatively safe
gas, but in practical coal mining there was always the danger that
the requisite conditions for an explosion might be allowed to
exist simultaneously. Even though an explosive mixture of
methane and air might exist underground, that might not lead
to great danger unless it happened that some source of ignition
was introduced into the mixture. It was obvious that if the
amount of methane was less than that which would admit of
ignition taking place there would be little danger of disaster if
sparking did take place underground.
Attention was directed to the possibility of sparking taking
place at the ringing points in signalling systems due to the disconnection
or breakdown of the safety device now usually attached
to relays and bells. Explosions had taken place because of
sparking at switch contacts on machines, the covers of such switch
cases having been left off after examination or incorrectly bolted
down after having been replaced. On the one hand the trouble
might arise from carelessness and on the other it might arise from
inaccessibility of joint to thorough examination.
The lecture was followed by the showing of two films which had
been prepared by Mr. Grice to show the procedure of shot-firing
and the methods of testing electrical plant which is submitted to
the Mines Department for examination prior to authorisation for
use. These films were followed by the audience with great interest,
the shot-firing film having an especial appeal to those employed
in doing that kind of work.
At the conclusion of the lecture and demonstration a hearty
vote of thanks was accorded to Mr. Grice and his assistant for
their kindness in coming so far in the circumstances of the blackout
to renew their acquaintance with a Wigan audience.
 |
 |
|
Names mentioned in this article
|
 |
 |
| Name | Age | Occupation | Notes |
| Grice, C. S. W. | | S.M.R.B. | |
| Onions, O. J. | | Chairman | |