21st October 1939, Page: 116, Column: 1 Inflammability Of Coal DustsIt is stated in the Seventeenth Annual Report of the S.M.R.B. (2s. net, H.M. Stationery Office) that the inflammabilities of coals from twenty seams have been determined at the request of the colliery managements concerned. The inflammabilities, as measured by the percentage of incombustible matter required to make a non-inflammable mixture, agreed to within 5 per cent. with the inflammabilities calculated from the volatile matter contents of the dusts. The inflammabilities so expressed of (a) the dust prepared by grinding coal from a Yorkshire seam and (b) two dusts from the roads through which this coal is worked, were found to be identical. On the other hand, dust prepared from another Yorkshire seam required the presence of 10 per cent, more incombustible matter than did the corresponding road dust. In the tests made in the 4-foot diameter gallery at Buxton, only the portions of coal or inert dust finer than the 60-mesh B.S. test sieve appeared to play an appreciable part in an explosion. An examination has been made of the standard apparatus with a view to determining its suitability for testing the inflammability of dusts passing through a 60-mesh sieve and to judge its general convenience. This examination has suggested that the following modifications should be made to the published description of the test: The dust to be tested should be placed directly in the dust-tube leading to the furnace rather than in a loose metal boat. A short brass plug, with a 3/16-inch diameter hole, between the air reservoir and the dust-tube, helps to obtain consistency of results. The volatile matter content of a coal is a fair guide to its inflammability. In the hope of finding a better guide, the reactivities towards oxygen of about 100 coals are being determined. The method is to pass air over a layer of the coals in a glass tube heated in an electric oven. From the composition and volume of the inflowing and outflowing gases, the rate of consumption of oxygen is calculated. This measures the reactivity of the coal. About 80 coals have so far been tested. Their inflammabilities are yet to be determined. The reactivities are also being determined by means of a modification of the "ignition-temperature" apparatus of Wheeler. In this apparatus air is passed through coal heated in a furnace, the temperature of which is raised at a constant rate. The temperature of the coal, at first below that of the furnace, rises more rapidly as the result of oxidation and overtakes the temperature of the furnace. The point of coincidence is taken as the "ignition-temperature" of the coal. The actual point observed depends on the experimental conditions as well as upon the nature of the coal. Estimation of Fusain in Coal. The usual method of determining the fusain in coal depends on removal of other constituents by oxidation with a mixture of potassium chlorate and nitric acid. As indicated in an earlier Report, no conditions have been found under which the coal is rendered completely soluble whilst the fusain associated with it remains unattacked. The resultant error depends on the proportion of fusain in the coal and on the type of coal, and no conditions could be found which reduced the error to negligible proportions. As this difficulty is inherent in the method, attention has been turned to physical methods of estimating the fusain. One method is to oxidise the coal mildly and then float the fusain from the residue by a process of froth flotation, Under this treatment all but the fusain is expected to sink. In the Investigators' experience, the separation is incomplete; thus, after repeated treatments of one sample, only about 70 per cent. of the fusain present was recovered. A method suggested by Davis and Younkins is to concentrate the fusain in the coal by floating the bright coal from it in a liquid of suitable specific gravity and to complete the purification of the fusain by electrostatic means. Tests at Sheffield show that the electrostatic separation is not efficient, but that ordinary gravity separation, accelerated by centrifuging the coal in a liquid of suitable density, can effect a complete separation. With four coals of different ranks, the separation of the fusain from the rest of the coal was complete after three-fold treatment of the "sinks" and the "floats." The same density of the liquid proved to be suitable for all four coals tried. The chief difficulty in the method is manipulative, namely, to separate cleanly the "floats" from the "sinks" when emptying the centrifuge tube. This was overcome by freezing the liquid in the lower half of the tube to entrap the "sinks" there and allow the "floats" to be poured off without being contaminated. Tests have been made to determine the proportion of a magnesian limestone dust, of fineness such that 70 per cent. passed the 240-mesh B.S. test sieve, required to suppress the inflammation of coal from the Blackshale seam (Derbyshire), under the standard conditions of test in the 4-foot diameter gallery. The coal, as mined, was ground to a fineness such that 85 per cent. would pass through the 240-mesh sieve. By calculation from the volatile matter content of the coal dust and the relative efficacy of limestone dust, the presence of 525 per cent. of limestone dust should be required for the suppression of inflammation, corresponding to the presence of 68 per cent. of total "basic incombustible matter." In the test, the presence of 50 per cent. of limestone dust was found to suffice.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||