9th September 1939, Page: 75, Column: 1 Mine VentilationBy R. Clive, Prof. D. Hay, M.C., B.Sc., and Prof. I. C. F. Statham, M.Eng. Excerpts from "Mine Ventilation: a Review of Present Theory and Practice (Tenth Report of the Midland Institute Committee) on Mine Ventilation." presented at the genera] meeting of the Institution of Mining Engineers. Concluded from page 50. Measurement of Mine Ventilation. Many methods are available for the precise measurement of rates of flow of air and gases in pipes and tunnels where specially constructed fixed measuring points are used, but the measurement of air-flow along underground roadways presents certain difficulties. The determination of quantity involves the separate measurement of air-velocity and cross-sectional area at the measuring station. To obtain the velocity of the air-stream it is essential to measure some physical effect arising from the motion of the air. Two such effects have been found by experience to afford suitable means of measuring velocities in ordinary mining practice, namely, pressure changes associated with the motion of the air and mechanical effects, such as the rate of rotation, or amount of deflection, induced in light vanes suitably mounted in the air-stream. Occasionally methods based upon the rates of cooling of hot bodies are employed for measuring air-velocities. An instrument employing the first principle is the pitot-static tube which enables the velocity-head to be measured and of which various forms are available. The pitot tube is capable of taking "spot" readings only and cannot be used as an integrating instrument; although yielding a comparatively high accuracy its use is usually justified only when great accuracy is required. The accuracy of velocities measured by the pitot tube is influenced by the accuracy of the manometer employed. The velocity-head for an air-velocity of 100 feet per minute is about 0.0006 inch W.G. and consequently a micromanometer capable of reading very low pressures is essential. Two instruments which depend for their action on the mechanical effects of an air-stream are the vane anemometer and the Velometer. The Vane Anemometer. — The average velocity of an air-current is usually about 90 per cent. of the maximum velocity at the centre, and this average is normally obtained by traversing the anemometer over the full section of the roadway. The instrument should be attached to a rod so that the observer can stand on the down-stream side of the station and hold the instrument normal to the air-stream in order to eliminate error due to "yaw." The measuring station should be in a straight length of roadway of uniform character extending for not less than 5 to 6 roadway diameters with 4 or 5 diameters of uniform section on the up- stream side. Measuring stations should not be chosen where spaces occur between the supports and the sides of roof since attempts to allow for the effect of these spaces introduce error. Regular calibration of anemometers is of the utmost importance since the moist and dusty atmosphere of a mine and the rough treatment to which mining instruments are often subjected cause the vanes to rotate more slowly. It is suggested that recalibration should be made at least annually by a reliable authority. The Velometer. — The Velometer is, in effect, a swinging-gate meter. It is a direct-reading instrument, giving spot readings only, and indicates air- velocities in feet per minute without the necessity of timing or calculation. The standard instrument for mining practice is the orifice type, which is usually fitted with two scales giving ranges of 300-3,000 and 30-300 feet per minute, respectively. The measurement of areas is an important factor in determining the quantity of air flowing. Where velocity measurements are taken at points of uniform section and lining the area can be obtained with fair accuracy by ordinary linear measurements, but at points of irregular section considerable error is likely to arise unless special care is exercised. An accurate profile sketch should be made and all the dimensions as measured should be marked on the sketch. Ventilation and the Dust Problem. In coal mining the most prevalent dust is that produced from the comminution of the coal itself, and although there is no evidence that coal dust is harmful to health, its existence in the air in large concentrations gives rise to material discomfort so that adequate ventilation is needed to ensure the health and safety of the workers. The presence of coal dust in high concentrations also reduces the efficiency of illumination, thereby increasing accident risk from other causes. On the other hand, high-velocity air-currents aggravate the dust nuisance by carrying the dust throughout the mine, so that in practice it is necessary to balance the advantages and disadvantages of the circulation of large volumes of air. Apparently there is no risk under normal conditions of the formation of coal dust clouds of sufficient density to give rise to danger from ignition and propagation of flame, but, unless the dust is collected by some means, it is deposited on the roadways and may give rise to dust accumulations which become dangerous when raised as a cloud. The dust produced from the surrounding strata, being incombustible, reduces the danger from ignition and propagation of flame, but if it is siliceous in character its inhalation in quantity may give rise to silicosis. It would appear, however, that most Coal Measure rocks immediately associated with coal seams do not contain sufficient free silica to give rise to danger from this cause.
|
|||||||||||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||