15th July 1939, Page: 4, Column: 1
Cables For Shot-Firing
With the object of giving an authoritative opinion on shot-firing
cables work was undertaken by the Exploder Sub-Committee of
the Explosives in Mines Research Committee. In order to make
some of the tests, e.g., simultaneous firing of shots in rippings,
special permission had to be obtained from the Mines Department.
That explanation was made in the introduction to his paper
on "Cables for Shot-firing," presented by Dr. H. Stafford, M.Sc.,
at the summer meeting of the Institution of Mining Engineers.
Before starting the practical work involved, the properties
demanded of a good shot-firing cable as found by experience were
noted and an examination was then made of the cables to be found
at local collieries to see to what extent they met these requirements.
A good cable must be light in weight and flexible, have considerable
tensile strength, have low electrical resistance with high insulation
resistance, be impervious to water, and resistant to damage by
flying debris. Since there must sometimes be damage to a cable,
electrical faults ought to be easy to detect and repair. Finally,
the cost of a cable must not be too high.
Cables in use at local collieries were examined, Dr. Stafford
explained, with special reference to their length of life and cost
and the frequency of miss-fires where they were used. The
conductors in every case were four 0.018-inch section copper and
this is adequate. The current even for simultaneous shot-firing
rarely exceeds 2 amperes and the resistance of a 100-yard length
of twin cable when new is about 2.5 ohms. Badly-jointed cables,
however, are often used, and one cable having 20 joints in the
12 yards of its length nearest the face of a drift was found to have
a resistance of 25 ohms.
The rate of destruction of shot-firing cables generally is high,
and, for this reason many collieries prefer to use the cheapest
types available. Again, the life of a cable often depends mainly
on the ease or otherwise with which a shot-firer can obtain a new
one. At some collieries it is the practice to join new pieces on
to the old cable, at others this is deprecated. At Colliery B,
where the apparent rate of destruction of cable is highest, the
miss-fires record is best. At this colliery new cables are readily
obtainable and the manager believes that the cost of shot-firing
cables is less than the cost of delay caused by using damaged
cables.
The cables referred to above are all of the same cotton-covered
type. Dr. Stafford said the cable has many good features; it is
light in weight, 4 to 8 lb. per 100 yards, and flexible, but not so
that it cannot be controlled. It is often an advantage to be able
to "set" a cable to place it out of danger from falling rock. When
breaks in the cable occur they are comparatively easy to detect
and repair. The broken ends are tied together in a reef knot
and the conductors twisted together. Such a repair, if well made,
has no greater resistance than a continuous length of cable, and the
cable is as strong to resist pulling as formerly. The cables are
insulated either by vulcanised india-rubber or what is called a
special shot-firing composition. The chief disadvantages of these
cables are the ease with which they are damaged by only small
particles of falling rock and their weakness to resist pulling from
under fallen debris. The padding used for protection soaks up
water in wet mines, and when the insulation becomes damaged
there is leakage of current through the wet padding. In regard
to the form of construction, the round section cable is more convenient
to handle and coil, whereas the flat section soon tends to
kink. The round section cable is also slightly more resistant
to damage, but faults in the fiat section cables are easier to detect
and repair.
Cables with Plastic Insulation.
On the Continent, plastic material has been used for insulation
for detonator wires for some time and it was decided to try it for
shot-firing cables. This material is tough and fairly resistant to
abrasion, and as it is not necessary to use tinned conductors with
it these cables are relatively cheap. Having referred to a number
of samples obtained Dr. Stafford said that Cable No. 6 was made
to a specification based on experience with other types of cables.
The conductors were composed of eleven 0.012-inch copper wires
twisted round a central jute cord. Plastic insulation was used,
each conductor being covered separately and the two conductors
then joined to make a cable of figure-8 cross-section. The conductors
were such as had proved satisfactory in a previous experimental
cable and the figure-8 construction was adopted to combine
the advantages of two single-core cables with the convenience of
a twin cable. Plastic insulation had proved fairly resistant to
damage and there was no padding to soak up moisture. The
cable weighed 4.9 lb. per 100 yards and the cost was approximately
£6 10s. per 1,000 yards.
Seven experimental shot-firing cables were tested, and of the
seven shot-firers using the cable three were enthusiastic about
it, three had no objections but did not like it any better than the
cotton-braided type, but the other shot-firer complained that the
cable became entangled when uncoiled.
The cable proved to be much more resistant to damage than
the cotton-braided types but was not so good in this respect as
the best cab-tyre cable. The average life of the cable was about
twice that of the usual types. This, as pointed out by Dr. Stafford,
is important in relation to the relatively low cost. There were
no complaints from any of the shot-firers about the difficulty of
detecting breaks and none of them was able to break the cable
by pulling it from under fallen rock. The relatively small bulk
and weight of the cable were a great advantage, as it was possible
to carry a regulation length of shot-firing cable in a coat pocket.
The cable was not, however, as convenient to handle as one of
round section. The figure-8 construction has most of the
characteristics of the fiat twin types, yet, on account of its light
weight, ease of handling compared very favourably with the
round-section cotton-covered types. The figure-8 construction,
however, simplified the detection of faults and from this point of
view none of the cables tried equalled it. The cable was waterproof
and did not become slimy when dragged through water.
In short, the cable appeared to satisfy most of the conditions
required of a good shot-firing cable.
Cables for Simultaneous Shot-firing.
With reference to simultaneous shot-firing Dr. Stafford said
the problem was solved by the provision of single-core cables and
wherever possible these were laid one up each side of the roadway.
This arrangement has also the advantage that it facilitates coupling
up a round of shots at the face of a drift or in a ripping, and it is
easier to place the cables out of the way of falling stone. It would
appear from particulars given in a table that in spite of the more
severe conditions of simultaneous shot-firing, particularly in drifts,
the life of these cables compares very favourably with that of twin
cables used for firing shots singly in coal and rippings. This is
mainly due to their position at the sides of the roads and to the
fact that they are not trailed about and repeatedly coiled and
uncoiled. The life and service obtained from comparatively cheap
single-core cables laid semi-permanently down each side of the
roadway were better than were obtained from the best cab-tyre
cables when both were used for simultaneous shot-firing in drifts.
There have been no miss-fires due to cable faults where single-core
cables were employed.
 |
 |
|