|
6th May 1939, Page: 344, Column: 2 Colliery Explosions And Fires — IIShot-Firing StandardsUnder the sub-head standard of ventilation for shot-firing, the Safety in Mines Commissioners in the course of their Report* refer to the requirements of Clause 6 (f) (i) of the current Explosives in Coal Mines Order. They point out that there is at present no approved alternative to the flame safety-lamp for the purpose of the examination, and it is obvious that the shot-firer can do no more than satisfy himself that no indication of gas can be seen on the lowered flame of his lamp. In other words "clear of inflammable gas" does not mean absolutely clear, or even "free" from inflammable gas in the sense defined in Section 29 (1) of the Coal Mines Act, 1911, but something less than 1¼ per cent., according to the skill and experience of the shot-firer. At the same time, even with that limitation, the provision, if conscientiously observed, implies that a high standard of ventilation must be maintained by the management to enable shot-firing to be carried on in mines which are at all gassy. The shot-firer has little or no control over the general standard of ventilation, and the provision in Clause 6 (f) (i) is clearly designed to deal with what may be described as a local emergency condition, corresponding to the cutting off of electric current from a machine if the presence of gas is detected in its immediate neighbourhood. There is nothing In the present law which lays down any standard of ventilation which must be maintained in the working face as a general condition of practising shot-firing there. Subject to the adoption of the recommendation regarding the general use of sheathed explosives, and of proposals made for limiting the number of shots fired by any individual shot-firer, so as to give him ample time among other things for making his examinations for gas, the Commissioners think that any general requirement as to the condition of the ventilation is sufficiently covered by the recommendations made on this subject in an earlier chapter (see No. 18 Vol. 49). In addition to the examination for gas within a radius of 20 yards immediately before the shot is to be fired, the shot-firer is also required by Clause 6 (d) of the E.C.M.O. to examine the hole for inflammable gas issuing from it before charging it, and he is not to charge the hole if he finds any inflammable gas. The Commissioners feel it is difficult to propose that the general use of sheathed explosives should be coupled with more stringent precautions in the way of examination for gas, unless future experience shows that the existing precautions are insufficient. What they propose is that there should be a provision in Part II. of the E.C.M.O. that no shot-hole shall be charged until immediately before it is to be fired, and that every shot shall be fired by the shot-firer who charged it or who was present at and responsible for its charging. It has frequently been said that if all the requirements of the E.C.M.O. were faithfully and conscientiously observed on every occasion when a shot is fired, the risk of accident, whether from ignition of firedamp or from any other cause connected with the use of explosives, would be almost negligible. At present, unfortunately, the standard of competency appears in some cases to be deplorably low. The Commissioners have recommended the adoption of the Holland Committee's recommendations as regards the qualifications of deputies and they agree with that Committee that as regards shot-firers "neither the duties nor the degree of responsibility assumed by the two classes of officials varies to the extent of justifying any distinction" in qualifications. They accordingly recommend that shot-firers should be required to qualify in precisely the same way and under the same conditions as deputies. As regards supervision, some managements may adopt the system, which is general in Germany. of putting all the shot-firers under the control of a foreman shot-firer who would be responsible both for supervising all matters connected with the use of explosives in the mine and for training prospective shot-firers. In any case, however, when a shot-firer is at work in a deputy's district, he should be under the supervision and control of that deputy. Whether the E.C.M.O. remains in its present form or is recast on other lines, the due observance of the necessary precautions in shot-firing cannot be expected unless adequate time is allowed for the purpose. Shots Fired per Shift. The Commissioners consider that the instructions given in each instance by the manager ought not only to provide for the maximum number of shots to be fired by each shot-firer during his shift, but should also limit the number of shots that he may fire in any one hour, so as to guard against any temptation on his part to make up for unforeseen delays by hurrying over his work in the latter part of the shift in order to achieve the permitted total. They are of opinion, in principle, that there should be a statutory overriding limit, of general application, on the number of shots that may be fired in any one hour, but they do not feel able to propose a specific figure for this general limit, because the various additional precautions in shot-firing they have recommended will no doubt add to the time necessarily occupied in firing a shot, and they think it better, therefore, not to attempt to recommend a figure based on existing experience, but to leave it to be fixed at a later date by the Secretary for Mines in the light of experience of the time found normally to be required for firing a shot under the new conditions. The Commissioners do not agree with those who would assign shot-firing to the deputy simply because he is the most experienced man. The most experienced man cannot personally undertake every duty, and the most remunerative way to make use of his experience is in the supervision of others who are actually doing the work, not in performing the work with his own hands. If these principles are fairly applied, the instances in which a deputy will be able to undertake the firing of as many as ten shots in his shift should be exceptional, and it is recommended that the manager should not be permitted to fix a higher figure than this without first obtaining the district inspector's consent. Even when lower figures are fixed, however, the inspectors should keep a close watch on any shot-firing by deputies to ensure that it does not interfere at all with the full and proper performance of their safety duties, and in the event of any objection by the inspector in this matter his decision should be final. Simultaneous Shot-firing. In mines or seams in which the use of permitted explosives is required, except in driving stone drifts or in sinking pits, the firing of two or more shots simultaneously in the same place is prohibited by Clause 6 (g) of the E.C.M.O. The Commissioners quote evidence given by Dr. R. V. Wheeler and Mr. R. J. Shaw (Colliery Managers), and express themselves as being strongly impressed by the safety advantages claimed for simultaneous firing therein outlined. Its practice would also greatly facilitate the firing of shots between shifts, or the total withdrawal of workmen from the face, when shots are being fired on the face or at the face rippings. The objections of the Mineworkers' Federation are noted, and the report states that the risk of miss-fires can be minimised by such precautions as carefully testing and grading detonators, making sure that the circuit is complete before firing, and the like, but some risk remains-and, however remote it is made by these and other suitable precautions, it is likely to remain. At the same time, experience both in this country and in other countries, where simultaneous firing is permissible and is practised on a large scale, appears to support the view that the risk in question is a small one. The Commissioners recommend, therefore, that any necessary provision should be made for the experimental work to be vigorously pursued, if necessary on a larger scale, and carried to a definite conclusion, not only as regards multiple firing in rippings (to which the previous trials were limited) but also as regards multiple firing in coal. The investigations should, of course, be subject to such limitation on the number of shots fired simultaneously and such other appropriate safety conditions as the Secretary for Mines sees fit to impose. In mechanised mining, shot-firing is one of the few operations which cannot be greatly accelerated by machinery, and in some circumstances the limited rate at which it can be done must, to some extent at least, be acting as a brake on the cycle of work. The Commissioners' proposals to limit the number of shots that may be fired by any shot-firer or deputy during his shift may further intensify the braking effect, and they would not advocate the practice of simultaneous shot-firing except on the understanding that it is to be regarded primarily as a means of ensuring greater safety on the lines indicated. Some authoritative pronouncement to the effect that this view is also taken by the owners and managers of mines might do much to allay the suspicions of the Federation on this score. Shot-firing on Main Roads. Having reviewed evidence on shot-firing on main roads, including that relating to the amending Order of November, 1937, the Commissioners say they have made in their report a number of recommendations relating to the minimum dimensions of airways and haulage roads, to the desirability of improving the support of roads by the still more extensive use of steel arches and girders, to the straightening and grading of haulage roads and to the improvement of ventilation generally. These are all, in their view, of fundamental importance to the safety of the mine, and they are all likely to involve much additional work on the roads, both in bringing existing roads up to the desired standard and in maintaining it in the future. It would be unreasonable at the same time to refuse when they are necessary the shot-firing facilities by which this work is to be done, and the Commissioners are satisfied that if they are allowed the resulting improvement in all-round safety will far outweigh any possible risk involved in the provision of such facilities, subject to appropriate precautions being taken by way of adequate stone-dusting and effective supervision at places where shot-firing is necessary. Moreover, the general use of sheathed explosives, which has been recommended, should provide an additional margin of safety over and above the considerations which were in the minds of those who gave evidence on the subject. On the other hand, if the result of future investigation is to provide good grounds for the general adoption of simultaneous shot-firing at rippings, the opportunities for completing the necessary firing between shifts will be enhanced and the need for any relaxation of the existing provisions of Clause 7 (c) of the Explosives in Coal Mines Order will be correspondingly reduced. A good deal turns, therefore, on the administrative interpretation of the recent amendment, as regards what is held to be "work required for the safety of the mine" and what is meant by "delaying it unduly." A recommendation, which is subject to reservations by Messrs. E. O. Forster Brown, W. H. Telfer, and John Walker, is made that in all mines worked by longwall, where permitted explosives are required to be used, there should be no shot-firing at face-rippings while men are at work in the face, except with the consent of the district inspector. * Cmd. 5890. 7s. 6d. net. H.M. Stationery Office.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||