Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

25th March 1939, Page: 294, Column: 2

Steel Props At Coal Face

N.S. Research Committee Reports

At the meeting of the North Staffordshire Institute of Mining Engineers on 27th February, Mr. E. H. Vallis (Investigator) presented the report of the Safety in Mines Research Committee on "The Use of Steel Props at the Coal Face." Extracts from the report are appended.

Wood v. Steel Props.

Some of the relative advantages and disadvantages of wood and steel props may be noted. Wood props are lighter, easier to handle, may be shortened at the face, and are not as liable to cause injury to workmen either by the props falling or the workmen stumbling against them. It is claimed for wood props that they give warning of roof weights and that steel props do not. Tests have shown that this is not justified because, by the time a wooden prop commences to "creak," it has failed under the load and is doing very little work; thus, although the prop may be standing, it is not truly supporting the roof and the warning comes too late to be of much avail. Wood lids, of course, give the same warning whether used with wood or steel props.

Wood props, however carefully selected, are not of uniform strength, and the unexpected failure of one prop may throw excess load upon its neighbours, causing them in turn to fail and perhaps bring about a fall of roof. Steel props are, in general, of a uniform strength greatly in excess of that of wood props of similar size. For instance, a 4-inch prop of "room dry" Scandinavian timber, 4 feet in length, will fail under a load of from 15 to 20 tons, whilst a 4-inch external diameter steel tube, wood filled, or a 4-inch x 4-inch steel joist prop of the same length, will sustain a load up to 65 tons.

In wet or damp mines wood props are at a further disadvantage, as is borne out by tests (S.M.R.B. Paper No. 72) which showed that room dry timber is about 50 per cent. stronger than saturated timber.

Steel props are, of course, considerably heavier than wood props, but this difference is more or less offset, especially on inclined faces, by the fact that new props have not to be transported along the face every day as in the case of wood.

In case of fire occurring at the face the advantage of steel props is obvious, and instances are on record of the complete loss of a face having been averted as a result of the use of steel face supports.

In the use of steel props an indirect advantage in roof control lies in the necessity for more attention to the systematic withdrawal of props from the goaf.

Types of Steel Props.

There are two main types of steel prop : the yielding and the rigid. Yielding props are not now in use in North Staffordshire. Rigid steel props are of two main types — (a) a prop fitted with a device, such as a wedge, which enables the prop to be set or withdrawn by tightening or slackening the wedge (the wedge prop), and (b) a prop with no such device and which must therefore be set and withdrawn in the same manner as a wooden prop (the plain prop).

Comparison between Plain and Wedge Props. — Tests have been carried out to determine the setting load that can be imposed upon plain and wedge props of the girder type. The props employed were 4" x 4" section 4 feet in length; the floor was rigid and a soft wood lid 2½" thick was placed at the bead of each prop.

The maximum load obtained with a plain prop was 24 cwts.; a prop fitted with a wedge having a slope of 14° (the most commonly used wedge) received a load of 3 tons, whilst with a wedge of 11° slope a load of 6 tons could be obtained. These tests were carried out in a press on the surface, but it is reasonable to assume that steel props fitted with wedges are set more firmly underground than are plain props. This is a matter of considerable importance, as shown by comparative results obtained underground where certain wedge props were set as tightly as possible while others were set less tightly and the subsequent swinging of the props was measured.

It was noted that the wedges of loosely set props were liable to slip back when the load eventually came on, and they thus did not develop the desired resistance to the convergence of the roof and floor. No slipping of the wedges was observed in the props set initially tight. It should be stated that slipping of wedges in observed cases has not occurred with wedges having a slope of not more than 11°.

A second advantage of wedge props is that they can be set more easily at any desired angle. At a face where mixed steel props are in use, measurements of the angle of setting showed that, compared with plain props, the wedge props were set, on the average, 3° nearer to the normal. This may not appear to be a great difference, but the 3° is an average, and individual variations were much greater.

The wedge prop is more easily withdrawn than the plain prop, but that in itself may, in some instances, be a disadvantage.

A natural condition for which wedge props are not suited has been observed where the roof settles down on the prop on the release of the wedge; this roof disturbance renders the subsequent recovery of the prop an operation requiring considerable care. In such circumstances it has been found desirable to pull the prop with a Sylvester at the moment of releasing the wedge.

Relative Merits of Props.

In considering the relative merits of wedge and plain props the weight of the head of the wedge prop becomes an important factor in thick seams where a prop of 6" x 5" section may be in use. Three men are often required to set such a prop in inclined seams whereas a plain prop may be set easily by two men.

Tubular props of 5½" diameter are in successful use in a seam 8 feet in thickness and girder props of 6" x 5" section arc also in use. A plain prop of 6" x 5" section and 6 feet in length weighs 150 lb., and its efficient setting becomes a matter of some difficulty. Further, if such a prop should be knocked out or should otherwise fail and strike a man the consequences may be serious.

Although wedge props have certain advantages, the present tendency in the North Staffordshire coalfield is towards the more extended use of plain props on account of their simplicity, ease of handling, absence of protruding parts, less liability to damage and lower initial cost.

Prop Sections. — Props of tubular section and of girder section with parallel and with incurved flanges are in use in North Staffordshire. Weight for weight, the tubular props are the stronger, easier to handle, less likely to cause injury through persons knocking against them, and they are, in general, taken to more kindly by the colliers. They must be filled to prevent buckling under load and generally a wooden core is used, which has the advantage of being lighter than sand.

H-section girder props are more commonly used. The chief advantages of this prop over the tubular section are that it can be straightened more easily and that the caps and feet can be shaped at the colliery, thus enabling props to be made from the straight portions of damaged and disused steel arches. Various shapes of foot can be tried at little expense in order to find that which best suits the conditions.

General Observations.

The particulars of installations of steel props given in the report show that, in seams up to a thickness of 8 feet and inclinations up to 1 in 3, there is no single limiting factor to the successful use of steel props.

In thicker seams and at higher inclinations the weight of steel props compared with that of wood renders their setting a matter of considerable difficulty.

Within the suggested limits, conditions unfavourable to steel props are (1) A varying thickness of seam; (2) A weak roof with a strong floor.

At a face where the seam is liable to vary in thickness by more than, say 6 inches, it is obviously impracticable to use the ordinary type of rigid steel supports. This is a condition where a prop which permits of length adjustment, and not too complicated in design to stand up to the rough usage of pit conditions, would be acceptable.

At faces with a weak roof and a floor which the prop does penetrate, the prop heads are forced into the roof and their withdrawal becomes a matter of difficulty and danger.

Where the extent of roof and floor convergence between the setting and the withdrawal of the props is such that the props are forced either into the roof or into the floor so far that they cannot be withdrawn with reasonable ease, the introduction of steel props of any design is not likely to be successful. It may he that in such circumstances an adjustment in the sizes and spacing of the packs, together with close supervision to ensure that the walls are well built and the interior stowed tight, will so reduce the extent of the height reduction as to permit the withdrawal of the props without undue difficulty.

When considering the installation of steel props it is advisable first to measure the height reduction, and when found to consider how it may be accommodated. The convergence may be met either by the crushing of wood lids or bars, or by the penetration of the prop into the floor. It is not desirable for the thickness of a lid to exceed 6 inches, and therefore any height reduction in excess of (say) 4 inches must be accommodated by floor penetration. The design of prop foot to permit the required penetration and no more must then be considered since, if penetration be excessive, the prop will not only be difficult to withdraw but will not offer adequate support to the roof.

Very careful supervision is required to ensure successful results, both with regard to the systematic setting and withdrawal of the props and the careful checking of the quantity to ensure against possible losses. At the collieries where steel props have resulted in the most marked decrease in the cost of face support the props, are counted and reported upon daily, following which the attention of the persons concerned is drawn to mislaid props before they are beyond recovery.

Accidents. — Figures are not available on a sufficiently large scale to show the effect of the introduction of steel props upon the accident rate. The possibility of men being injured owing to striking or being struck by a steel prop has been noticed and another possible source of accident is a prop flying out from under a steel bar, but this does not occur provided a wood pad not less than 1 inch in thickness is placed between the prop and the bar.

In view of the more uniform and greater strength of steel props as compared with wood, and of the fact that they bend rather than break, together with the more adequate supervision and systematic setting and withdrawal that is likely to follow their use, the Committee are of the opinion that the use of steel props under the conditions indicated in the report has resulted in better working conditions and a reduction in the number of accidents from falls of ground at the coal face.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Vallis, E. H.    Investigator  


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print