11th February 1939, Page: 251, Column: 2 Packing System for "Floor" ControlIn the discussion before the Midland Institute of Mining Engineers arising out of the reading of the paper by Dr. D. W. Phillips and Mr. L. Walker on "The Control of Longwall Roadways by Means of Packs." Mr. A. Holdsworth said that a few years ago he had occasion to use the double packing system in the Warren House Seam, not for the purpose of roof control, but for floor control. Arch girders were used in conjunction with single packing, but trouble was experienced due to the floor heaving and the arches distorting. They decided to adopt the following system. The roadway to be supported was 10 feet wide between packs. Floor girders 14 feet long were laid at 2 feet 6 inches intervals and the space between was covered from girder to girder with short props. Packs 3 yards wide were built at the gate side and these packs helped to hold the girders down. A 3-yard waste was left, then another 3-yard pack built. Arch girders were erected on the floor girders, and props were placed between the flanges of the arch girders for their full length. The result was that the floor heaved in the 3-yard waste instead of in the gate, and the arches were not distorted. Since reading Dr. Phillips's paper, he had realised that the method they adopted assisted the roof control, which explained why the arches were not distorted. As previously mentioned, however, the double packing system was introduced for floor control.
|
|||||||||||||||||||||||
![]() |
||||||||
|