|
31st December 1938, Page: 201, Column: 1 Choice Of Underground Machinery — IIIBy John T. Pringle, M.I.M.E. From paper before the annual general meeting of the Associates and Students' Section of the North of England Institute of Mining and Mechanical Engineers. Signalling — Telephones — Lighting. These three items of underground equipment — Signalling, Telephones, Lighting — are great aids to safety and efficiency when the choice of gear is properly made and installed. The apparatus should be flameproof and of low tension. For signalling too little attention has been paid in the past to return systems by which a signal sent is returned automatically to the sender for checking, thereby ensuring that a correct signal is sent and received. It is obvious that accidents have occurred by wrongly given signals. Watertight and gasproof bells and equipment are available in many forms, and single stroke bells are preferable for safety reasons, as even at low pressure of 25 volts a spark at the break of a trembling bell will ignite gas. In spite of improvements trembling bells are somewhat in disgrace. The use of relays has improved the safety of haulage roads; here the signal wires are connected to a small battery, the relay closing a local circuit in which the bell and the full strength of the battery is included. Other methods designed to secure safety are to have no signal wires carrying current, as in the Davis-Fryar and General Electric systems with pull wires. In a great number of mines there is even at this time a poor system of telephones. There is nothing about a mine so efficient in time saving as the telephone, and all mines should have a good system throughout. A small exchange should be at every pit bottom and lines laid to every district and to the surface offices. The system of portable telephones for attaching to bell wires and carried in the pocket should, if at all used, be secondary to the method of having fixed transmitters and receivers at as many points as possible in the mine. Each apparatus must be placed in a safe position carefully protected from rough usage, damp and other effects, and consist of two receivers, calling bell, and a dry cell for the microphone. There are many excellent makes to choose from. At the pit bottom, engine-houses, landings, in the Mothergate and along conveyor systems, electric lighting should be provided. High and level roadways use watt lamps, as fewer are necessary than with metallic lamps, and this reduces the chance of trouble. Where the roof is low use metallic filament lamps which can be protected by flameproof enclosure. Overhead lamps having well glasses, and side lamps with glasses of lens form, are usual. If compressed air be the power, air power D.C. generator units can be employed to advantage. The voltage will be to H.O. regulation, and it should be remembered that the lower the pressure the stronger the filament with corresponding larger current. For A.C. lighting single-phase transformers to take current from the 3-phase system are employed. The secondary current from each single-phase transformer being used for lamps at different parts, care should be taken that the currents supplied by each of the three transformers are kept in balance. It is to be regretted that the system of local lighting has not reached the stage where coal-cutters and conveyor units can be fitted with lighting provision within the machines as in U.G. electric locomotives, but for wider light distribution. It should be remembered that the conduit system is not so good as the armoured cable system owing to the armouring being capable of withstanding heavier strain than will the conduit when movement takes place. Condensation and corrosion also take place inside the conduit, and external corrosion is difficult to avoid when enamel is chipped off. Where the conduit is adopted there is a great deal to be said in favour of cables insulated with a homogeneous material such as maconite, since, unlike V.I.R. cable, it will not deteriorate if internal condensation takes place. Armoured cable can be erected like power cable. It is governed by Reg. 129 (a), and by using it the adoption of such protection artifices as are required for the conduit system are unnecessary, these at best being makeshift. Unit type distribution boards can be attached to the armoured cable and single iron armoured cables can be led to carefully selected switches, junction boxes, lantern and bulkhead fittings. The lighting of haulage roads comes within the province of the permanent system, but it is not economical to light the whole of them, only junctions and important points being treated; this is unfortunate, as a very appreciable number of accidents are caused by lack of illumination. The chief difficulty is probably the drop of volts due to the very low voltage of the lamps, and systems should be chosen to avoid this as much as possible. It should be remembered that whitewashing the walls, roofs and props will increase the intensity of lighting compared with that of the same untreated road. There should be no bar to the lighting of the coal face in non-fiery mines on similar lines as is in use at Newbattle Colliery, viz., by 25 c.p. lamps 10 feet apart and fed from a 50-volt supply from a transformer with 500-volt primary. The lighting is comparatively steady due to bar cutters being used, these being less severe in load than other types.
|
|||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||