Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

8th October 1938, Page: 97, Column: 1

Mine Ventilation Pointers

These notes are based on the Mines Inspectors Reports for 1937, The price of each Report is 1s. net. Copies are obtainable through H.M. Stationery Office.

Ventilation is rightly regarded as one of the most important problems the mining man has to deal with. So much is at stake it cannot lightly be regarded without running into trouble. The Inspectors of Mines also view the position seriously, and in some of the annual reports considerable space is devoted to the question as it applies to the area concerned. It may be opportune in this series of combined reviews to record what they have to say about ventilation generally, following upon the Safety Suggestions which appeared in the last issue of this journal. Other subjects will he dealt with in rotation following the custom adopted in recent volumes.

Auxiliary Ventilation Discussed.

Noting that the horse-power of electric motors used for auxiliary ventilation in Scotland rose in the last twelve-month period from 6,203 to 6,482 Mr. T. Ashley, the Inspector in charge of that Division, says the installation of inbye auxiliary fans ought to be regarded generally as a grave and costly reflection on the efficiency of the ventilation of the mine as a whole. He expresses his views as under :—

It is doubtful whether many of the auxiliary fans now in use would really be needed if proper care and attention were given to airway maintenance and the stoppage of preventable leakages between the intake and return airways. Instead of hastily installing an inbye auxiliary fan when difficulty is experienced in the ventilation of a section, a ventilation survey should first be made to find out the root cause of the trouble. Such a survey would, in many cases, show that attention to leakage or other modification or improvement of the existing system is all that is necessary to remedy the trouble.

It should be borne in mind that the use of auxiliary fans introduces special problems, and places additional responsibility upon the management to see that these fans do not in themselves become a danger. Because of the great tendency to cause recirculation of air, electrically-driven auxiliary fans are a possible source of ignition of firedamp. When they are installed this possibility should be carefully considered and provided against as far as possible; the motor and switchgear should be covered by a Buxton certificate and should, in addition, be housed in a place ventilated by intake air. Even when a mine is worked with naked lights, these precautions should he adopted.

Since it is practically impossible to stop all re-circulation, especially when auxiliary fans are situated in inbye districts, care should be taken to ensure that the fan is of suitable design in respect of pressure and capacity and is so situated that any leakage or re-circulation which may occur will not involve danger. It is obvious, for instance, that it is safer to have a leakage circulating from intake to return than vice versa. The direction taken will depend very largely upon the pressure, capacity and choice of site of the fan, and these can only be determined satisfactorily by a ventilation survey. Generally the proper position for an auxiliary fan, intended to increase the flow of air in a section, is at the outbye end of the intake or return to that section, for then, if the fan is of suitable design for its work and suitably installed, the only leakage will ho from the intake to the return — a safe leakage.

The position of the fan in relation to doors or other connections between intake and return is particularly important. The fan, whether situated in intake or return, should always be on the outbye side of such connections, so that any leakage through the connection will be from intake to return.

Under no circumstances should screens and doors be neglected. There is too often room for improvement in this respect. The explosion at a Lanarkshire colliery showed how soon an explosive mixture can accumulate in the face of a thin seam when the ventilation does not take its proper course.

Effect of Mechanisation.

The question of ventilation has occupied a good deal of Mr. H. J. Humphrys' time as the Inspector in Charge of the Yorkshire Division. He considers that its importance cannot be overestimated in the Yorkshire coalfield with its fiery seams, more especially since the advent of mechanisation. It is only needed to consider the fires that have actually broken out near the face, the seven and a half million shots fired during the year, and the 22,000 horse-power of electrical machinery at the face, to realise that ventilation must occupy a foremost place in the minds of all entrusted with the supervision of mines.

An effect of mechanisation has been the difficulty of ventilating a mine consisting of only two or three panels of varying lengths. It has been met in some cases by increasing the water-gauge, and there are instances of water-gauges of 5½ inches at mines liable to spontaneous combustion. At Bentley Colliery where the airways are large and the air is split efficiently, the water-gauge is only 1.65 inches at the surface for 340,000 cubic feet per minute. Over a period of eight years in a mechanised mine working the Barnsley Seam, the water-gauge has increased 2½ inches, and the quantity of air decreased 50,000 cubic feet per minute. At another mine working the same seam by hand, the water-gauge has decreased 0.7 inch and the quantity increased 100,000 cubic feet per minute.

Mr. Humphrys can only repeat the recommendations in previous years' reports as to voluntary standards of ventilation, ascertained by frequent sampling and maintained by attention to such matters as leakage, splitting and large airways right up to the face.

Plan in Advance.

During the year a good deal of trouble has been experienced at some collieries in return airways running along the rib sides of panels in which the firedamp percentage increased considerably as the distance from the face increased. Something could be done by putting a greater breadth of packing next the rib to minimise fracture of the overlying beds, but the main thing is to increase the quantity of air passing, or if this cannot be done, to reduce the length of split. In some instances, the effective area of airways has been reduced by the provision of larger tubs. Attention, Mr. Humphrys proceeds to say in his latest annual report, is still not always given early enough to the question of ventilation, and it is apparently left to take care of itself until trouble arises, when an attempt to find a remedy is made. The scheme of ventilation should always be planned in advance, and the size of airways required can be determined by consideration of available data, i.e., firedamp emission per unit length, length of face and roadways, and maximum permissible air velocity.

As to the advantages to be derived from a ventilation survey the Inspector says it is interesting to note that as the result of one made by Professor Statham in the Thorncliffe Seam at Waleswood Colliery, during the year, and of the alterations undertaken in consequence, the quantity of air circulating in the seam has been increased by 12½ per cent. and a larger proportion is reaching the working face. The water-gauge for the pit has been reduced 5 per cent. It is expected that further substantial advantages will accrue when the full scheme of improvement, which includes certain airway enlargements, and the construction of a number of air-crossings, is completed. The survey has been supplemented by planning for future development, including the specification of the sizes of all main and district airways in accordance with the estimated requirements of the various districts.

Mr. Humphrys is convinced that there would be an enormous gain in efficiency if the ventilation of all mines of appreciable size were surveyed and planned on these lines.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Ashley, Theodore    H.M. Divisional Inspector of Mines  Whos Who Page
Humphrys, Herbert John    H.M. Divisional Inspector of Mines  Whos Who Page
Statham, Ira Cyril Frank, Prof.      Whos Who Page


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print