|
10th September 1938, Page: 74, Column: 2 Care Of Electric LampsIn his general remarks on lighting in the 1937 Report on the Yorkshire Division, Mr. H. J. Humphrys comments on the reduction of upwards of 3,000 in the number of flame safety-lamps in use being offset by an increase of 6,900 in the number of electric safety-lamps. The number of the latter fitted with alkaline batteries has increased 40 per cent., those with lead acid batteries showing a decline. There was a large percentage increase in the number of electric cap-lamps in use. Remarking that Mr. J. Cowan, the junior electrical inspector, has been giving attention to the care and maintenance of pneumatic electric lamps, Mr. Humphrys says he would like to see their use still further extended. It seems that Mr. Cowan finds, where trouble has been experienced, that it falls under one or more of the following headings :— (1) Defective cut-out (with one type of lamp) in which condition the light continues even if the well-glass is broken or removed. The remedy is to make a daily test. If the cut-out is in order, the light goes out at once if the air supply is shut off. The most common cause of defect is the accumulation of dust, oil, or rust on the diaphragm. (2) Water from the compressed-air mains getting into the lamp. This can be prevented by water traps and a filter near the lamp to remove the moisture from the air. The filter is probably also the most effective way of preventing the accumulations of dust, etc., mentioned under (1). (3) Dust and dirt finding its way into the lamp. A filter again is the remedy, and one that has been put into use successfully at Treeton Colliery consists of a short length of strong two-inch pipe filled with cotton wool packing, held in position by a brass-mesh pad, and a reducing coupling at either end. (4) Worn governor-brakes which cause the bulbs to have a short life. Frequent examination, with perhaps replacement of the shoes, will reveal the condition of these parts. (5) Worn rotor-bearings. The lamp should not be allowed to run so long that this defect is apparent by the noise. Mr. Humphrys says that if the lamps are brought periodically (say monthly) to the surface for overhaul and repair, and proper records kept, there should be little trouble with this useful form of lighting.
|
|||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||