7th May 1938, Page: 343, Column: 2 Electricity And Fire RisksMembers of the National Association of Colliery Managers and the Association of Mining Electrical Engineers were in attendance at the last meeting of the South Staffordshire and Warwickshire Institute of Mining Engineers, when information bearing on the avoiding of risks of fire through electrical defects in mines was given by Mr. J. A. B. Horsley, H.M. Electrical Inspector of Mines. He said one reason for apprehension regarding the electrical hazard was that no preliminary stage in an electrical defect causing a fire was open to direct observation, and such tests as could be applied to the installation in a mine could not be depended upon to discover the liability before it became an actual risk. Reliance must therefore be placed on automatic means to detect the breakdown and to cut off the current as soon as it occurred. An analysis of all such fires from 1919 to 1937 inclusive showed that, of the seventy-three instances, only eight fires were associated with inflammable oil used as an insulator and cooling medium in switchgear and transformers. The preponderating cause was defects or damage to cables and, where it was possible to form an opinion as to the originating cause, there was evidence of mechanical injury, a faulty joint or a loose terminal connection. The outbreaks caused nine persons to lose their lives and twenty-six to receive injuries. Mr. Horsley discussed the use of automatic safeguards, both against over-current by means of fuses and automatic circuit breakers (thermal or electro-magnetic) and against leakage to earth. Much could also be done to control fire risk in a colliery by attention to details in electric installation and to maintenance and proper use of apparatus and cables. He suggested that the following precautions should be observed: Live cables should be switched off when not in use; mechanical injury to cables should not be ignored, even though it has not resulted in a breakdown; suspected defects should receive immediate attention; automatic protection appropriate to the circuits should be provided; automatic devices should receive skilled and regular examination to ensure perfect operation; and particular attention should be given to the mechanical attachment of cable ends and to the protection and sealing of the insulating material at terminals.
|
|||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||