23rd April 1938, Page: 321, Column: 2 Firedamp Detector RegulationsIn recent issues references have been made to the Report of the Committee on the Firedamp Detector Regulations, whose principal recommendations may be summarised as follows :— (1) The Regulations have justified themselves, and, subject to the amendments the Committee suggest, should be renewed without time limit. (2) Where flame-safety-lamps are used as firedamp detectors under the Regulations, they should comply with the requirements as to lighting performances laid down in the First Schedule to the Lighting Regulations, and, except with the written permission of the manager, no other type of lamp should he issued to the "competent workmen" in whose charge the detectors are placed. (3) The number of detectors to be provided on longwall faces should not be altered. In all other workings, one detector should be provided at the face of every separate working place. In addition, detectors should be provided to repairers working in the return airways. (4) The "competent workmen" should not be certified until they have passed tests of ability to estimate actual gas caps with reasonable accuracy as seen in gas chambers or otherwise, and a special pamphlet should be prepared and supplied for the instruction of the competent workmen." (5) In any seam in which safety-lamps are required to be used by Section 32 (1) (a) of the Coal Mines Act, 1911 (a) The use of an automatic detector should be compulsory in conjunction with any electrical motor in use at the working face; (b) on every longwall face where electrical power is in use, one out of every eight detectors required shall be of an automatic type, unless the firedamp content of the return air from such face [as ascertained by the manager within the preceding twelve months, in the manner laid down in Section 32 (4) of the Coal Mines Act, 19111 is normally found to be less than 05 per cent., subject to maximum numbers of two and four in the case of single- and double-unit conveyor faces respectively; (c) in bord and pillar workings, one out of every four detectors required should be of an automatic type in "broken" workings adjoining the goaf. Two members of the Committee, Mr. G. P. Hyslop and Mr. A. E. Naylor, were unable to subscribe to all the conclusions arrived at by the majority of its members. For example, they cannot support the claim, so often made, that the automatic detection of firedamp, even by a perfect instrument, will have a material effect upon the security of the workmen underground. In their Memorandum of Reservations, having indicated that the points of difference relate to Sections 5 and 6 of the majority report, Messrs. Hyslop and Naylor state the position as they see it. The recommendation they are unable to subscribe to is No. 5, and in lieu thereof they recommend :— (1) As soon as an automatic detector has been shown by tests to be satisfactory in regard to accuracy and reliability in indicating 1¼ per cent. of firedamp after a period of service underground, the provision of such detectors whore electricity is in use on the face should be made compulsory. (2) The present approvals granted to automatic detectors under the Regulations shall be deemed only provisional, and that final approvals shall be deferred until such time as final tests have been passed.
|
|||||||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||