|
23rd October 1937, Page: 122, Column: 1 Underground Fire FightingBy F. S. W. Dobbs. From "Some Notes on Underground Fire Fighting and Kindred Matters," introducing discussion before the Manchester Geological and Mining Society. This paper is framed principally to form the introduction, and the media to a discussion of a subject which is of paramount importance and interest to all responsible mine officials. Underground fires may be placed under the following headings: (1) Fire caused by friction; (2) Fire caused by naked lights; (3) Fire caused by failure of electrical gear; (4) Fire caused by machinery (face) or other; (5) Fire caused by ignition of gas; (6) Fire caused by spontaneous combustion. It is recorded that simple friction fires have been the cause of losing districts, whilst fires caused by spontaneous combustion, because of their method of treatment, are very rarely the cause of serious loss. First Aid Materials. In dealing with underground fires of a type included in the first five sections, it is obvious that the first few moments of the outbreak are the most important, and upon the method of attack, and the appliances which are readily available, depends the success, or otherwise, of the venture. If this is correct, it must follow for all practical purposes that the most readily available materials must of necessity be of a first aid character, and under this heading we have appliances and materials fulfilling such requirements. Sand or Stonedust. — Sand, or finely ground dust such as is ordinarily used underground for dealing with coal dust, has been proved to be most effective when brought into use immediately after an outbreak of fire has occurred, but this material has its limitations, as it can only be expected to have an extinguishing effect if applied to fires close to, or at floor level, difficulty of application preventing its effective use on fires on more or less vertical surfaces. Hand Extinguishers. —Here is an appliance which may be particularly useful in subduing a fire in its early stages, but to be of the utmost benefit should, I think, conform to the following requirements: (1) Simple to operate; (2) Capable of being easily transported in confined spaces without risk of premature discharge; (3) Not liable to undue deterioration; (4) Simple to re-charge. The latter requirement is of extreme importance, as everyone who has had experience of fire fighting will realise. These appliances also have their limitations in so much that the time of effective operation is limited, and the jet of water thrown from them is also limited to distance. Small Hand-operated Portable Bucket Pumps. — Small pumps of about 4 gallons capacity are now being tried, and are said to be specially suited for low workings. Manual Pressure Pumps and Tanks. — Where water can be readily obtained, and in reasonable quantity, and transported quickly to the scene of the fire, these appliances fill the breach between the first aid appliance and what could be considered as a more or less permanent fire-fighting installation. I refer, in using the word "permanent," to permanent water mains under pressure. Permanent Appliance. — I believe everyone will agree that the most positive and effective method of fighting a fire is by means of water in unrestricted quantity, and under a suitable pressure, and water mains kept always under pressure give us this means. It is realised that certain difficulties present themselves in establishing permanent water mains underground. From the foregoing remarks, may I venture to suggest a possible framework from which colliery officials might build up a suitable, and probably collective, means of dealing with underground fires, always having in mind particular domestic circumstances. Surface Equipment. Central Fire Station. — There might, on the surface, be established a Central Fire Station, serving one or more mines, where supplies of materials could be stored, and kept always in good order. Supplies of fire hose should be kept with nozzles, monitors, etc., standardised as regards fittings and couplings with the Central Rescue Station, and if possible with the local Fire Brigade. Also supplies of extinguishers and re-charges for same, that is, types of extinguishers for both ordinary fires and electrical fires. The extinguishers should also be standardised with those of the Rescue Stations, and also with those of neighbouring collieries. Spare manual pressure pumps should be available for speedy transport underground, and supplies of sandbags available for filling, together with supplies of tools, specially marked, and only to be used in case of fire ; several pairs of asbestos gloves suitable water tanks for filling and sending below ground; suitable plans showing position of all valves and hydrants on both the surface and underground mains. The standardisation of equipment is particularly emphasised, so that an interchange of equipment between one colliery and another, or between one group of collieries and another, would be rendered possible, and would build up not only an individual means, but a collective means of dealing with mine fires in a particular area. Underground Arrangements. If a fire station is maintained on the surface, then a pit bottom station might be dispensed with, but it is suggested that a station at this point is advisable. Inbye. — A small fire station should be maintained at the entrance to each main district, or, in the case of several small districts starting from a common point, one station might suffice. Equipment. — Supply of extinguishers and re-charges or bucket hand-pump; empty sandbags; buckets; tools; hosepipes; manual pump and tank. Suitable connections for compressed air mains where these can be conveniently utilised as water mains. Sand or stone dust dumps might be provided at suitable points, say every 500 yards along each intake and return airway, with a reasonable amount, say 5 to 10 tons of material, always kept in each dump. Sand buckets, as receptacles for easy transport, to be kept at each dump, in addition to supplies of empty sandbags. Bags of stone dust might be placed at reasonable intervals along each main roadway, say every 50 yards, to be used only in the case of fire, and changed when necessary to prevent deterioration. A reasonable supply of stone dust should be readily available at each gate end. Fire Extinguishers, or Small Bucket Hand -pumps. — These should be kept at all conveyor loading points, and all other points which might be considered vulnerable, as they are useful only in the very early stages of a fire, and should be available for immediate use. In the case of water mains under pressure standard hydrant couplings should be provided at regular intervals, and the mains extending inbye to all principal road junctions, or to within a distance of the face that would be within the range of accessibility by means of additional portable hose. Water tanks should be kept in readiness at the junctions for transport of water inbye. It is preferable that mains should be kept at low pressure, and boosted if required to the safe working pressure of canvas hose. Loss of pressure through friction in mains should not be lost sight of when designing the system. Water mains should be tested periodically as regards pressure and volume, as an assurance of supplies of water being always available. Fireproof zones might be made on both intake and return airways to prevent fire spreading for unlimited distances. Steel ventilation doors might be erected for use in emergencies. Finally, suitable sites should be chosen in each district for the building of stoppings, and the wing walls and footings built, and roof excavated, so that they may be quickly completed should the necessity for sealing off arise. Maintenance of Appliances and Organisation. It is desirable that systematic inspection of all appliances should be made by a responsible official at least once a month, and reported upon. All extinguishers should be brought to the surface to be discharged and re-charged once each year, and the outer cylinders of extinguishers should be hydraulically tested once every four years. However well equipped a colliery may be with up-to-date fire-fighting appliances, the utmost benefit cannot be derived unless suitable organised personnel is available for its manipulation, and it is desirable that specially trained fire squads should be arranged for at each mine, comprised of men who have been trained to handle the apparatus, and who understand the limitation of the apparatus handled, and preferably who have a knowledge of the underground workings. The foregoing notes refer principally to fires which are sudden in their appearance, and give little or no warning of their outbreak. Others arising from spontaneous combustion usually require different treatment, first-aid methods being of little or no use. Each official should know beforehand what his duties would be in the event of a fire call being made. The various appointments should be in the form of written authorisation, issued by the manager. Such authorisation would set out as far as possible the duties of the individual. Surface. — During the whole time there should be a competent executive officer on duty on the surface, through whom all instructions should be taken and given, and whose office would become the central clearing house for information in all matters, and where records of all transactions could be compiled, logs being kept of all matters that future reference might require. Written permits should be issued from this office to every person whose duties require him to go underground. Officials' Duties. The duties of the surface engineer would be to immediately warn all other surface officials, and arrange for the attendance of sufficient tradesmen, carpenters, mechanics, pipe fitters, etc. he should be responsible for suitable attendants being placed at the telephone, and should arrange for sufficient messengers. He should generally supervise the storekeeper, lampman, head banksman, and surface labourers with regard to supplies of material for use underground, and should be responsible for all necessary transport arrangements. The storekeeper should attend at the store-room as soon as possible, and immediately check the available supplies of cement, bricks, stone dust, brattice cloth, extinguishers, re-charges, tools, etc., and should make himself conversant with all additional sources of supplies, and report to the principal official, who would then make the necessary arrangements to augment supplies from available sources. The head-lampman should keep a careful record of all persons to whom lamps are issued, and should only issue lamps to persons presenting the written permits. Clerical assistance might have to be arranged. The head-banksman should keep a written record (or be responsible for this being done) of all persons entering or leaving the mine, and see that no persons enter the mine without having the written authority. The electrician should call in his staff, and arrange for supplies of suitable cable and fittings to be available for temporary alterations and extensions to underground telephone installations. The surveyor should be responsible for the preparation of plans of the affected workings, of a suitable size to enable handy reference underground. The person in charge of the first-aid room should see that there was an ample supply of first-aid equipment available during the emergency period, both for use underground and on the surface. He should arrange for an ample supply of stretchers, blankets, hot-water bottles, burn dressings, etc. The responsible person in charge of the rescue room should see that the room was clear and tidy for the immediate use of the rescue workers. He should arrange that the reviving apparatus and birds be ready for sending underground, upon receiving instruction from the executive officer. The under-manager should be responsible for seeing that all workmen, except those selected by him to assist in dealing with the emergency, have been withdrawn from the district or districts affected. The manager should confer with the underground officials as to the work required to be carried out, and would be the responsible official to confer with and give instruction to rescue teams, as to the work to be attempted, and he should appoint a responsible official to take over his duties when he was not underground. Instruction to rescue teams should as far as possible be given in writing. Fire Fighting Methods. The methods by which a fire might be fought are: (1) Application of stone dust or other inert dust; (2) The use of extinguishers or small bucket hand-pumps; (3) Application of water under pressure (manual pumps and tanks or water mains); (4) Filling out of heated material; (5) Flooding of the area affected; (6) Stopping off the area affected; (7) Sealing off the shafts penetrating the seam. It is only when the fire has grown to such dimensions as to be beyond control that any of the three latter means of fire fighting would be resorted to, any one of which requires careful and considered treatment. Temporary stoppings would be erected at predetermined points, consisting of sandbag walls, with debris fillings between, to be followed by brick stoppings of a more or less permanent character, so reducing the oxygen beyond the stoppings and allowing the fire to smother itself out. If found to be leaky, these latter stoppings might be faced with plastic clay. The type of stopping to be built would be governed by circumstances. Examination of samples of air taken from behind the stopping through suitable pipes left in when building the stopping, enable us to determine fairly accurately the state of affairs in the affected area. These latter remarks apply equally to the last method, viz., that of sealing the shafts. Heating caused by spontaneous combustion is often detected previous to the actual outbreak of fire, and during this interval steps can be taken to minimise the danger of actual outbreak. The lessons to be learned from experience emphasise the necessity of having men specially trained for fire fighting; materials readily available; surface personnel organised prior to an occurrence; supplies of water always available, if not inbye underground, at least at the bottom of each shaft; taking fullest advantage of the resources of the Central Rescue Station, as regards both material and personnel; having some simple means of controlling the ventilation (by other means than the main ventilating fan) always available. Prevention is always better than cure, and falls under the following headings: (a) Use of non-inflammable materials as far as possible, and use of flameproof equipment; (b) Fire-proofing roadways where fire risk is probable; (c) Exercise by care of workmen, and strict attention to Regulations. In conclusion, I am of the opinion that more systematic research into the question of the use of the non-inflammable materials underground, with the possibilities of eliminating the causes of underground fires, would render great service to the industry, and so tend to minimise the possibility of underground fires, which appear to be increasing.
|
|||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||