Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

22nd May 1937, Page: 357, Column: 2

Compressed Air and Coal-cutting

Discussing the paper by Major E. Ivor David on "Air Compression Transmission and Metering" at the April meeting of the South Wales Institute of Engineers, Mr. Robert James, Principal of the Treforest School of Mines, said that, in many South Wales collieries in which coal-cutting and conveying were practised, the consumption of compressed air varied between 7,000 and 8,000 cubic feet of free air per ton of coal output. On the basis of the larger figure, a colliery producing an output of 1,500 tons per day would utilise approximately 11.5 million cubic feet of free air compressed to 75 to 80 lb. gauge pressure per 24 hours. Assuming a generating cost of 90s. per million cubic feet which represented a good average figure, that corresponded to a cost of 8.32d. per ton of output. It was not generally realised that on a cold day, with the air fully saturated at freezing point, each 1,000 cubic feet of air drawn into the compressor system carried in suspension 0.3 lb. of moisture, and that on a warm day in summer, with the air saturated with moisture, each 1,000 cubic feet of air contained as much as 1.89 lb. of moisture.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
David, E. Ivor, Major      Whos Who Page
James, Robert    Principal  


 

mail
Mail:
Webmaster
Back