8th May 1937, Page: 341, Column: 2
Dust Effects on Lighting
It is well known that dust in the atmosphere reduces the light
from any given source, and in their paper before the North
Staffordshire Institute of Mining Engineers Messrs. T. David Jones
and W. L. Gyles offered some observations on their efforts
to measure the effect of dust on lighting at the coal face. The
conclusions arrived at were: (1) The necessity for periodically
wiping off deposited dust from the well glasses at conveyor loading
points and other dusty places is clearly proved. (2) The clear gas-filled
bulb fitted in an opal well glass is physiologically superior
to other bulbs tried, and a loss in efficiency is brought about by
substituting cadmium yellow or daylight blue bulbs under both
normal and dusty conditions. (3) Limestone dust was much
harder to get into suspension than coal or even shale dusts, but
mixture of coal and lime dust (dried) when once put into suspension
took longer to settle out than coal dust alone. (4) The dust
raised by shovelling and throwing the coal was of a smaller particle
size than that produced by throwing artificially prepared dust
into blower suction; in the latter approximately 60 per cent.
of the dust used was above 5 µ whereas in the shovelling test
only 20 per cent. of the dust particles were over the size.
 |
 |
|