Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

13th March 1937, Page: 277, Column: 2

Boiler Plant Instruments

At the February meeting of the North Staffordshire Institute of Mining Engineers Mr. J. Vickers submitted a paper on "Power Economies as Applied to Collieries," and he said that, providing a fuel, be it waste product or otherwise, contains sufficient heat units to justify handling, there is no difficulty whatsoever to-day in obtaining boiler plant of a type suitable for burning it usefully in steam raising. Discussing boiler plant efficiencies he proceeded to say that in many cases there is no apparatus on the boiler excepting the usual steam gauge and safety valve to indicate that any change in the load has taken place. If the boilers were equipped with steam flow meters they would indicate instantly any change which took place and thus give the fireman ample warning and enable him to maintain the thermal balance of the boiler plant. This might appear to be a very minor point, but in the course of twelve months it is possible for a considerable quantity of fuel to be wasted, and this in itself (in a reasonably large plant) would more than justify the installation of a steam flow meter.

Draught Gauges. — In order to ensure that the correct amount of air is being supplied to the fuel bed, it is essential that "draught gauges" be fitted to each boiler. Where only one gauge is fitted to each boiler, it is generally found that the best position is in the furnace directly over the fuel bed. In this position the gauge is constantly under the observation of the fireman, and by careful observation both in regard to water-gauge, thickness of fuel bed and type of fuel being used, the fireman should be able to judge the most suitable position for the dampers, and thus ensure the maximum possible efficiency under all conditions of load. Draught gauges are usually fitted to indicate the water-gauge at the bottom of the chimney or in the main flue, but whilst the indications at these points may serve a useful purpose, they give very little information in regard to the conditions of draught at the furnace. It is not uncommon to find boiler plants in operation with the dampers in one position, irrespective of the nature of the load and type of fuel. Consequently, when the boilers are operating on light load an excessive amount of air is drawn through the thin fuel bed, resulting in the cooling down of the furnace and the carrying away by the flue gases of a considerable amount of heat.

CO2 Recorders. — There is no better method of obtaining an immediate indication of any incidental changes in the efficiency of the boiler than by the continuous recording of the CO2 content of the flue gases. Referring to tests carried out by Mr. D. Brownlie on Lancashire boilers, the average percentage of CO2 on seventy- five colliery boilers tested is given as 8 per cent., and thus it will be seen that there was an average fuel loss of 22 per cent. Assuming that, say, 10 per cent. CO2 is the maximum average percentage that could possibly have been achieved, this would have resulted in a net saving of 4 per cent. Again, assume that one of the boiler plants was consuming, say, 850 tons of coal per week; then the net saving would have been 14 tons of coal per week, or 700 tons for 50 weeks, and assume the market value of the fuel used was 10s. per ton, then the value of the fuel saved would have been £350 per year.

Temperature Recorders. — It is also very necessary for the temperature of the feed water and flue gases to be constantly recorded in order to keep a check on the chimney losses, etc. Assume a boiler to be operating normally with 60 per cent. excess air, and an exit flue gas temperature of 500 degrees and without economisers or air preheaters. If economisers were fitted to the above boiler and the heat extracted from the flue gases and the temperature dropped to, say, 350°F., then the overall thermal efficiency (neglecting the incidental power consumption of economiser motor) would be increased by approximately 58 per cent.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Brownlie, D.      
Vickers, J.    Mining Engineer  


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print