Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

2nd January 1937, Page: 197, Column: 2

The Methane Detector

Tests in American Mine

Before the Pennsylvania Anthracite Section of the American Institute of Mining Engineers Mr. Arthur Glance, the Safety Inspector of the Salem Hill Colliery, in a paper on "The Methane Detector as an Aid to Mine Safety," said there were various instruments on the market which record in direct percentages the amount of methane present in the atmosphere. He instanced the Burrell methane detector, the Wolf, the Martienssen, the Mine Safety Appliance detector, and the Union Carbide Company methane detector, which last he has used extensively in making mine inspections. This methane detector utilises the effect of combustion of methane upon the surface of a heated filament, connected in an electrical circuit. The combustion of methane, on the filament, increases its temperature and consequently its electrical resistance, which causes a deflection of an indicating needle in the circuit. The deflection is dependent upon the concentration of methane in the atmosphere and is indicated in percentage on the methane detector dial.

The paper by Mr. Glance appears in the Institute's MINING AND METALLURGY, and the following notes on tests he made may be of interest :—

"The following practical test took place in the Salem Hill mine. The assistant foreman and myself met in a chamber and we decided to check each other in testing for gas. The vein was 11 feet thick and worked on double timber, pitch 300. After a slight delay to build a scaffold so that we could reach the roof, the assistant foreman made his test with a lamp and reported it clear. With the detector I merely took the miner's dressing bar, inserted the dressing edge under the clip on the side of the detector, and hoisted the detector to the roof. The meter registered 1½ per cent, of gas. This surprised the assistant foreman, because 1½ per cent, of gas can be capped on a flame lamp. To check himself, a higher scaffold was built so that he could see the flame on the same level as his eye and check his test more closely. This was done and a cap appeared on the lamp.

One of the gangways was next examined. It was dusty and one could barely see. I asked the miner if the place was clear and he replied that it was, and that t-he only burning in his lamp that he could detect was caused by the high dust content in the air. Upon looking at my instrument, which is unaffected by dust, I found 2 per cent. of methane. To prove my findings we immediately reduced the dusty atmosphere by sprinkling the section thoroughly with water, which is piped to the face of all our gangways for fire protection. Within a short time the dust was settled and I had him check again with his flame lamp. A noticeable cap could then be seen on the lamp, which again proved the difficulty of determining the methane content with a flame lamp in an atmosphere at all dusty.

"The following test was made in a flat seam, 6 feet thick. The place driven was 24 feet wide and 200 feet long. Testing here with the average flame safety-lamp could only be done within 3 inches of the roof, owing to the fact that the hanging hook of the flame lamp displaces 1 inch of height and the bonnet 2 inches more. If a 3-inch layer of methane were along the roof, the average flame lamp would not detect it and the place would be passed as clear. A place of this type could contain a large quantity of methane which, if ignited, would have disastrous results. With the methane detector, practically perfect detection can be made, for the detector can be held in a horizontal position against the roof and any gas present thus detected.

"As a final example, let us go to the main return. Often returns when tested for gas by the flame lamp are reported as clear, but upon testing with the methane detector the results are surprising. The colliery return delivers 106,000 cubic feet of air per minute. Testing with the flame lamp showed the return clear, but testing with the methane detector showed a daily average of 0.8 per cent. methane. A day's delivery of gas from this return showed 184,320 cubic feet of pure methane being released."


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Glance, Arthur    Safety Inspector  


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print