|
7th November 1936, Page: 138, Column: 1 Safety In Coal MinesEvidence of Research Stations DirectorThese notes are based on the evidence and statements of witnesses appearing before the Royal Commission on Safety in Coal Mines. Interesting and useful evidence given by the Safety in Mines Research Board before the Commission included the statement submitted by Professor R. V. Wheeler, D.Sc., F.I.C., Director of the Research Stations at Buxton and Sheffield, from which the following extracts are given :— Coal Dust Explosions. Coal dusts of the same degree of fineness but of different chemical compositions differ in their inflammability and, therefore, require different degrees of treatment on mine roadways to render them harmless. This can be expressed simply by saying that, if dilution with shale dust is the method used to render the coal dust on mine roadways harmless, some coal dusts require more shale dust than others. The relative inflammability of coal dusts can be gauged roughly by their contents of "volatile matter." A more certain measure of the inflammability of a coal dust in relation to its chemical composition may be required than that given by its "volatile matter" content; such a measure should be obtainable from a closer study of the constitution of coals or, empirically, from a correlation of some measurable property of coal dusts, such as their reactivity, with determinations of their inflammability. Further information is required regarding the conditions under which incombustible dusts lose their dispersability and regarding the means of preventing their caking. The specific action of certain salts, e.g., sodium chloride, in inhibiting the combustion of coal dust, as distinct from the behaviour of shales, for example, in suppressing combustion by the absorption of heat, requires further study. A method of rendering a deposit of coal dust harmless, alternative to the admixture of incombustible dust with it, is to wet it. Water alone is not an effective wetter of coal dust, but it can be made so by the addition of small quantities (1 or 2 per cent.) of a suitable "wetting agent." If a hygroscopic salt, such as calcium chloride, be also added, a mine roadway can be maintained in a dust-free condition without re-treatment over long periods if little or no fresh dust is being deposited. Firedamp Explosions. The lag on ignition of methane varies with the proportion present in the air and with the temperature and character of the source of ignition. The lag is particularly long, and the ignition temperature correspondingly high, if the source of ignition is a heated surface at which catalytic action can occur (e.g., a metal bar). The lag is exceedingly short when the source of ignition is an electric spark. Of all mixtures of firedamp and air, that which contains 10 per cent. of methane propagates flame at the highest speed. The speed of the flame decreases rapidly as the proportion of methane falls below or rises above 10 per cent. The speed of flame is increased by the movement of the mixture, as a current, by an amount which is approximately additive. The movement of flame during a firedamp explosion is affected by the environment of the explosive mixture, by conditions which may induce turbulence and resonance. For example, the speed of flame in a 10 per cent. methane-air mixture moving into a still mixture, is under one foot per second, but a speed of eight feet per second has been observed in uniform movement, a mean speed of 33 feet and a forward speed of nearly 200 feet per second in vibratory movement, a speed of nearly 2,000 feet per second in a tube fitted with obstructing rings, and a speed of over 6,000 feet per second under the influence of the detonation of an explosive. When a space is only partly occupied by an explosive mixture at the moment before ignition, the flame of the explosion will, in general, be projected much beyond the region occupied by the explosive mixture before ignition, because the expansion during inflammation is, as a rule, able to drive unburnt mixture ahead of the flame. In a straight roadway, the flame may be projected over a distance as much as six times the original length of the column of explosive mixture. A firedamp explosion can be extinguished after it has travelled some distance or, of more importance, before it has had time to develop, by causing it to encounter a cloud of a heat-absorbing dust (such as gypsum or borax). The formation of the cloud can he effected by the explosion itself. An analysis of the vibratory movement of flame shows that the vibrations represent resonance of the whole column of gas. Resonance can be reduced, and even eliminated, and the strain of an internal explosion on a flame-proof enclosure thus minimised, by damping the vibrations, e.g., by the provision of narrow slits in the container. Spontaneous Combustion of Coal. Problems encountered in pits where the coal is liable to spontaneous combustion are the early detection of an incipient heating; and, should it become necessary to seal off a heated area, the condition of the area behind the stoppings. The detection of a heating is commonly by the characteristic smell of "gob-stink," but an earlier indication may be given by systematic gas analysis, whereby an abnormal removal of oxygen from the mine air, and an abnormal formation of carbon monoxide, can be observed. The condition of the area behind stoppings depends mainly on the tightness and effectiveness of the stoppings. The formation of an explosive mixture behind tight stoppings depends on the relative rates at which inflammable gas accumulates (either by distillation of coal or by the evolution of firedamp) and oxygen disappears. The danger of an explosion is greatest during and soon after the completion of sealing off, and ceases to exist so soon as the upper limit of inflammability of the complicated mixture of gases within the sealed-off area has been exceeded. Danger of explosion occurs again during the removal of stoppings ; a heating in coal remains dormant even when the oxygen in the atmosphere has for long been reduced to 3 per cent., and fire may be quickly revived if air has access to such a dormant heating. The oxidation of coal can be hindered or prevented by the presence in the air of traces of certain vapours, or by the admixture of certain salts with the coal. Electrical Problems. Electrical plant in general (e.g., switchgear) can be prevented from causing the ignition of firedamp, through sparks at moving parts, by providing it with a flame-proof enclosure. In the design of encased electrical apparatus, it is important to avoid partitions such as may divide the interior into compartments communicating through a small opening. For, under these conditions, a firedamp explosion in one compartment creates a far more violent explosion in that adjoining. It is necessary that the covers of casings of oil-immersed gear should be almost completely closed; since hydrogen-acetylene-air explosions are very violent, the casings must be exceptionally strongly constructed. For electrical apparatus, such as signalling bells and telephones, operated by small currents, flame-proof enclosures may not be essential. Instead, the electrical characteristics of the apparatus (more particularly its inductance) may be so chosen that the system is "intrinsically safe." That is to say, any spark that may be formed during the normal operation of the apparatus possesses insufficient energy to ignite firedamp. The principle of "intrinsic safety" is applied also to the electrical apparatus used in shot-firing. The apparatus most often used is the magneto exploder. It is more difficult than with signalling-bells to render such exploders, particularly the high-tension exploder, intrinsically safe, for they depend on the electrical energy they supply for their efficiency as shot-firing apparatus. If they are so constructed that the energy they supply cannot yield a spark capable of igniting firedamp, they may be barely effective for shot-firing. The same difficulty does not arise with dry-battery exploders, because of the absence of inductance. The inability of such electric sparks as are obtainable from signalling apparatus and exploders to ignite firedamp is gauged by an empirical test. It should be possible to measure the energy in an electric spark (and the manner of distribution of that energy) and thus to obtain direct assessment of the intrinsic safety of electrical apparatus. The ignition of firedamp by static electrical discharge during mining operations has been suspected. It is known that, under certain conditions, the friction of dust particles passing along an air-pipe can generate electricity, and that sufficient can be stored in an insulated conductor to provide a spark capable of igniting firedamp. For this reason, air-pipes through which dust may be conveyed require to be effectively earthed. It has not been found possible, except under conditions entirely foreign to mining practice, to draw a spark, having sufficient energy to ignite firedamp, from the nozzle of a compressed-air pipe (a suspected cause of ignition), but the limiting conditions have not been determined. Mining Explosives. When charging a shot-hole, the safest condition of firing the explosive is provided when the detonator is next to the stemming and points towards the back of the shot-hole. The quantity of explosive required to do a given amount of work is least the more firmly the stemming holds in the shot-hole, the optimum condition being when the stemming remains undisturbed until the work of the explosive is fully completed. An efficient stemming material can be compounded of moist clay and coarse sand ; moist clay alone is frequently inefficient. The danger of an over-charged shot and the greater danger of a shot in a break can be considerably reduced, perhaps removed entirely, by the use of "sheathed" explosives. A sheathed explosive, as produced commercially, is a cartridge of a permitted explosive surrounded by a thin layer of sodium bicarbonate. This salt (one of many tested in an attempt to provide an inhibitor of the ignition of firedamp by explosives) apparently yields a protective blanket of steam and carbon dioxide, during the detonation of an explosive, which prevents the near approach of firedamp. As a result, an 8-oz. cartridge of a sheathed explosive when freely suspended in the most explosive mixture of firedamp and air can be fired without igniting the mixture. The action of the sheathing material for explosives at present used commercially (sodium bicarbonate) appears to be, in a sense, mechanical. A preferable material would be one which exerted a specific inhibition of the ignition of methane. It would be preferable also if a coherent coating could take the place of a powder. The conditions under which, during the testing of mining explosives, the ignition of methane is obtained are but little understood. Of the phenomena that accompany the detonation of an explosive, the flame, the shock-wave and the hot products of detonation, any one, two together or all three in combination, may be responsible for ignition; or ignition may sometimes be caused by hot particles ejected from the mortar. It is desirable, in order that the testing of explosives may be placed on a firm basis, that the possible influence of each factor should be evaluated. Safety-lamps. A modern flame safety-lamp can give three candle-power or more as compared with the 0-5 candle of the ordinary Marsaut lamp and the one candle to 15 candles of "combustion-tube" lamps, without necessarily impairing its efficiency as a gas detector. A flame lamp of high candle-power generates considerable heat, by reason of the perfect combustion of the oil. In a hot pit, the heat of the lamp may become excessive. It is desirable to study means of dissipating that heat. The effective light of a lamp can be augmented by the use of a reflector. The design of reflectors, in relation to the design of the lamps to which they are to be fitted, requires study. It is difficult to cause the ignition of firedamp by accidental damage to a flame safety-lamp. The flame-lamp is the most convenient means of testing for gas, and the presence of small quantities of firedamp can be detected by it with considerable accuracy. As an alternative to the flame-lamp, if a permanent record of the quantity of firedamp present in the ventilating current is desired, an automatic analysis apparatus, providing an analysis at intervals of about ten minutes, can be so arranged as to record such analyses on a chart over a period of, for example, seven days.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||