Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

1st August 1936, Page: 17, Column: 1

Protective Clothing For Rescue Brigades

The question of Protective Clothing for Rescue Brigades was considered by Mr. G. L. Brown, Assoc. H.W. college, in a paper at Bath before the institution of Mining Engineers, He referred to experience he had of fighting underground fires to illustrate the occasional need for sonic equipment that will assist brigades (1) to penetrate to the seat, of fire and form a working-base for direct attack without delay; (2) to go farther than is normally possible into a fire area to extinguish flame or to cool heated materials; (3) to position monitors for directing water on the extreme end of a fire or other section of it. About two years ago he tried asbestos suits, as used by fire brigades, and came to the conclusion that they were unsuitable for work at underground fires, as the conditions generally are different from those which occur at surface fires. More recently, rescue station authorities have been considering the suitability of modified types of asbestos suits, of which samples have been tried in a hot chamber at the Mansfield Rescue Station and comparison made with other kinds of clothing.

From experience in attacking fires behind seals with breathing apparatus, and the men wearing a minimum of clothing, it appears that the limit of endurance is half-hour periods doing light work in temperatures of about 120° dry bulb and 95°F. wet bulb. To be of practical value, therefore, improved equipment should permit of brigades operating for at least similar periods in higher temperatures, say up to 200° dry bull and 110°F. wet bulb.

Working in High Temperatures.

Pointing out that under conditions obtaining at mine fires special clothing would protect only against intense radiant heat, Mr. Brown said tests were made in high temperatures to find out which type of clothing was least uncomfortable and for what periods members of rescue brigades wearing breathing apparatus could do light work at various wet- and dry-bulb temperatures, the conclusions being :—

Clothing of any kind is most uncomfortable to wear once the body temperature begins to rise, this occurring in 20-go minutes at wet-bulb temperatures above blood-heat.. If effort is continued beyond this, a condition of extreme lassitude quickly occurs.

Asbestos clothing is least suitable, as it soon attains the temperature of the surrounding hot air and conducts heat readily to the body and to the inspired air when in contact with metal air-pipes. When used with a lining of other material the discomfort is increased due to the extra weight.

Less discomfort occurs when wool flannel covering is used on the body and apparatus. It is a better and lighter insulator. Least discomfort occurs when only ordinary trousers and wool shirt are worn, particularly at wet-bulb temperatures above blood-heat and dry-bulb temperatures of 120-130°F., but with the latter at 200°F. it is necessary to add a wool flannel hood and gloves to prevent scorching of the skin and burning of the face where metal parts of the apparatus touch it.

From this it is obvious that complete protection of the body is necessary for brigades to enter extremely hot areas when attacking fires. They would not be able to advance far under these conditions, as both rise in body temperature and the temperature of the inspired air from the apparatus would limit them to short-distance and short-period work. For the same reasons, extensive explorations should not be attempted in roadways filled with extremely hot gases coming from a fire.

An important factor when working in high temperatures with breathing apparatus, Mr. Brown said, is the condition of the inspired air. Dr. Haldane has referred to the possibility of breathing dry air at 230°F. in a similar environment, and Dr. E. M. Killick has shown that moist air at 135°F. can be breathed in a cool environment up to 1½ hours without increase in body temperature. In the tests that had been made it was shown that the limiting dry- and wet-bulb temperatures are much less than those mentioned when conditions of environment cause fairly rapid rise in body temperature.

It is of interest to note, the Author added, that when caustic soda absorbent is used discomfort is caused by dry throat, due to breathing air which is too dry in the period possible to use an apparatus. With soda-lime absorbent, discomfort is caused by breathing hot moist air which scorches the throat. The latter feeling is more discomforting than dry throat, and occurs earlier. At high dry-bulb temperatures the discomfort caused by both dry and moist inspired air occurs before discomfort due to rise in body temperature. In practical work this fact, along with checking of pulse rates, serves to warn brigades of approaching tendency to heat-stroke. They should then withdraw.

Operations with breathing apparatus should not be conducted where the external wet-bulb temperature exceeds 98°F., or where the dry-bulb temperature exceeds 120°F. The former limitation is necessary to avoid extreme body discomfort, and the latter to avoid discomfort from breathing dry or moist air caused by the nature of the absorbent and heating of air in metal pipes and "coolers." These limitations are for working periods of 20-30 minutes doing light work.

Working in high temperatures is limited to the capabilities of the breathing apparatus independently of the suitability of clothing to protect the body against external heat.

In July, 1934, members of rescue brigades and other workmen were burned by an explosion of gas while they were attacking an underground fire. Mr. Brown investigated the nature and extent of their injuries and in his paper gave full particulars to assist in forming an opinion as to the extent and kind of clothing needed. Presenting his conclusions he said :—

Because of the positions of the brigade members at the time of the ignition, and the nature of their burns, I think they were burned by the hot gases resulting from the explosion rather than by flame. They were not burned where ordinary clothing properly covered the body ; the most severe burns were those affecting the exposed hands and face. Those with more than minimum clothing (shirt and trousers) were burned less extensively, especially when fully buttoned about the neck, chest, and arms. From this it is concluded that the air normally enclosed about the body was not displaced by burning hot gases, which expanded into the roadways. If the head and hands had been clothed by woollen hood and gloves, respectively, it appears certain their burns would have been greatly minimised, if not altogether prevented. As their burns were confined mostly to hands, arms, face and neck, it seems essential that these parts should also be covered, despite any slight, discomfort, which is not considerable when working in normal temperatures.

"It is significant to note that there was no burning or scorching of clothing or apparatus. Those who wore apparatus were also protected, both back and front, by the leather parts. Light leather overalls or a boiler suit worn over ordinary trousers and shirt would, under similar circumstances, form a suitable body protection providing the whole is fully buttoned up. To complete the covering, gauntlet gloves should be worn to protect the hands and prevent hot gases being blown up the sleeves, and ????? fitting hood. preferably of wool flannel, is required to protect the face and neck. A strap should be provided on the trousers at each ankle, but if not, the bottoms should be tucked inside the socks to prevent the hot gases being blown up the legs. A hard hat and knee pads give added protection."


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Brown, G. L.      


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print