|
25th April 1936, Page: 331, Column: 1 Wire Ropes And Colliery PracticeThe subject of the paper by Dr. M. A. Hogan before the April meeting of the Midland Institute of Mining Engineers was "Wire Ropes Research in Relation to Colliery Practice." Two types of external wear are to be distinguished-abrasive and plastic, and the severity of internal wear is largely controlled by the construction of the rope which governs the nature of the contacts between the adjacent layers of wires. The failure of most ropes in service is brought about by two factors : (a) the increase in tension produced by the kinetic shocks associated with winding, and (b) the reduction in strength of the rope caused by the action of repeatedly applied stresses whilst the stresses which cause fatigue in the wires of a colliery winding rope are produced by variations in tension due to the motion of the engine, the elasticity of the rope, and shocks caused by rigid guides, shaft doors or gates, and the operation of drop-keps. Corrosion fatigue is brought about by the simultaneous operation of the two factors, corrosion and repeated stressing. Dr. Hogan said that experience had taught that colliery winding ropes must have a large factor of safety (ratio of the breaking strength of the rope to the weight of the load raised). From observations on a number of haulage ropes broken in service it appears that it is unsafe to allow any rope used on a main rope haulage to remain in service after the strength of the rope has been reduced sufficiently to bring the static factor of safety below 6. The factor of safety when the rope is new should be considerably greater than 6. Under the heading rope examination the lecturer said that when a rope is run slowly past the examiner he can do little more than verify that the rope is intact, and locate any broken wires which project from the surface. A more detailed examination is required to ensure the detection of other forms of deterioration. Certain parts of the rope should be cleaned and examined whilst the rope is at rest. Particular attention should be paid to the condition of the wires (bright or dull, rusty or pitted) both on the worn crowns and between the strands, and the amount of wear estimated. Any looseness or distortion of the rope should be noted, and the lay and diameter should be measured. In stranded ropes a general reduction in diameter usually occurs as the strands bed into the fibre core, but any sudden local reduction in diameter, which is not due to visible wear, should be regarded as a sign of dangerous internal deterioration. Dr. Hogan added :— Flattened strand ropes sometimes suffer very rapid wear due to a slight untwisting and rotation of the strands which leaves one corner of each strand projecting. This trouble would appear to be due to lack of care in handling the rope. In stranded ropes another form of distortion in which one strand sinks into the interior of the rope is sometimes observed. This trouble can generally be traced to the use of too small a core, and is dangerous because it leads to overloading of the other strands and to extra wear due to the distorted shape of the rope. In haulage ropes another type of distortion sometimes occurs which is thought to be originally due to kinking. One way of detecting this type of deterioration is by listening as the rope passes over a roller at full speed. It may easily escape detection if the rope is examined when running at low speed. Another method of finding the distorted places is by inspecting the rope laid out on the ground free from tension. On the Continent, the engineers of the rope examination service are accustomed to untwist selected portions of winding ropes sufficiently to allow the condition of the inner surfaces of the strands to be examined. It has been found that when this operation is carried out under expert supervision, with proper appliances, the strands return to their original places and no damage results. This method of examination does not appear to be used in Britain. Apart from untwisting the rope, the only way of finding out what is happening in the interior is by the examination of samples cut off at recapping. Except in the early stages, when the rope cut off has never passed over the pulley, the condition of the recapping samples is usually a reliable guide to that of the rest of the rope. The results of the examination of recapping samples yield very useful information with regard to the gradual development of deterioration. These results naturally require careful interpretation because in some instances the condition of the rope at the capel may be better than at some other part. The relation between the conditions at the capel and elsewhere depends to a large extent on the amount of rope cut off. Where a generous amount, say half a revolution of the drum, is cut off each time, the worst part of the rope is usually in the recapping piece. In examining the recapping samples, the condition of the rope both externally and internally should be carefully observed, any sign of fatigue, wear, or corrosion being noted. If possible, mechanical tests should be carried out on the wires, but the absence of facilities for mechanical testing does not remove the value of the rest of the examination. The mechanical tests applied to ropes fall into two groups: tension tests on sample lengths of rope, and tension and torsion tests on all or on a selection of individual wires obtained by unstranding a piece of the rope. While tensile tests on new ropes afford useful results, Dr. Hogan said the value of such tests on specimens which have suffered deterioration is doubtful, particularly when the result seems to be better than is warranted by the appearance of the rope. Tests on individual wires together with a count of the number of broken wires and of fatigue cracks give a better idea of the condition of such ropes. The torsion test is the most sensitive means for detecting fatigue cracks because a wire weakened even by a very small crack will probably fail after one of two twists. The crack will appear as a dark edge on the otherwise smooth fracture.
|
|||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||