|
1st February 1936, Page: 225, Column: 1 Means To Control Coal DustSome of the experiments which he has made in dealing with the problem of dust in coal mines were described by Mr. J. B. Sproston, M.C., manager of Chanters Pit, Atherton, at the last meeting of the Manchester Geological and Mining Society, in a paper on "Some Methods of Dealing with Underground Coal Dust." The dust problem he was dealing with was created by mechanised mining, and one could safely state in general terms that present mining practice had contributed a definite increase in coal dust. Perhaps owing to our eagerness to mechanise our output, the problem of concentrated and excessive dust was not anticipated. One was led almost to believe that some of the difficulties which had to be met following the introduction of mechanised mining had nearly outweighed the supposed benefits. He did not wish to imply that he was averse to machine mining, far from it, but be contended that modern methods had created conditions which, if not prevented, might produce an atmosphere in which it would not be fit to work. The general causes of dust and places where it is produced were: (a) Coal-cutting and heading machines. (b) Delivery point of gate-end loaders, gate conveyers, or equivalent. (c) Receiving point of gate-end loaders, gate conveyers, or equivalent. (d) Delivery points from face conveyors direct into tubs. (e) Coal getting by pneumatic picks or hand picks. (f) Filling on to conveyors. (g) High air velocities on face or loading points. (h) Coal face direction in relation to cleavage. Experiments in which Mr. Sproston took part were made to prevent or neutralise coal dust. They failed to remove the major portion of the dust and it was decided it would be better to turn attention to the collection of the dust rather than to its prevention and neutralisation. It was with the introduction of a conveyor that they decided something would have to be done to lessen the amount of dust created. The spraying of atomised water on the coal was first tried, but the dust was too fine to be laid by that method. They then turned their attention to the possibility of covering the conveyor head and of leading the dust away by suction fan into an old roadway to be used as a dust chamber. The method certainly produced an improvement, but the dust was still in their way and had to be removed. Each week approximately 4 cwt. or 5 cwt. of dust created by the one conveyor was collected. Even then all the dust could not be swept up, and some had escaped on to the working face, so this experiment could only be considered partially satisfactory, for it catered only for a fixed loading point, and even then was not beyond criticism. From it, however, they learned that the shrouding canopy over the conveyor head would play a very large part in the success of any type of collector that might be evolved in the future. It would have to be constructed with a view to air-tightness, allowing at the same time manipulation for loading tubs and passing them outbye ; the loading point also must be protected from any sweeping ventilating air-current. More experiments were made until finally it was discovered that a filter made of "wood wool," a material with a large filtering area, gave satisfactory results. Encouraged by the successful working of that type of filter, a portable collector using the same material was constructed, and after many trials a collector was developed which, although not perfect, was fairly efficient. This embodies a "Meco" 12-inch suction fan passing about 2,500 cubic feet per minute and a filter. This filter is packed with wood wool to such a degree of tightness as to allow air to pass through to the outside, but at the same time at a velocity low enough to allow the dust to settle in the interstices of the wood wool. As a final filtrate the outer layer is coated with thin oil to collect the finer particles of dust. The whole is surrounded by a covering of hessian, but its object is not entirely as a filter but to prevent spillage of dust during transport. The collecting capacity of these filters is approximately 60 lb. of dust per unit. Mr. Sproston suggested that this type of collector or filter embodies many points which might be embodied on other collectors which may be put on the market, thus: (1) Capable of use with fixed loading points, gate-end loaders, or receiving points; (2) Should be able to accommodate large or small quantities of dust; (3) Should be made of any size to fit into tubs for transporting; (4) No special provision should be necessary in a roadway where they are used; (5) The dust must be capable of removal daily; (6) Easily erected, no skill required ; (7) Low construction cost. Using this type of filter on a shaker conveyor delivering 150 tons of coal per shift, from 15 lb. to 25 lb. of dust was collected, and on a gate-end loader delivering 250 tons up to 80 lb. of dust was collected. "By the introduction of these collectors," Mr. Sproston said "we have obviated the necessity of wearing goggles and respirators at leading points, and at the same time we have been able to reduce unnecessary stone-dusting at ripping edges and roadways." There were distant murmurings, he said, of new legislation which promised a standard of explosibility of coal dust. It was not unreasonable to assume that those standards would be higher than those now in force. If that were so, then the only means by which those standards could be kept would be to control the coal dust at the source of generation.
|
|||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||