Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

7th December 1932, Page: 176, Column: 1

Penetrating Power Of Lamps

While experiments were being carried out at the works of Hailwood and Ackroyd, Ltd., the impression was gathered that there was a possible difference in the quality of vision between electric and flame lamps. The penetrating power of lamps being deemed a matter of importance, the firm decided to call in an independent authority to investigate the problem, the work being undertaken by Mr. D. McKerracher, B.Sc., A.R.T.C., whose report has been published, with four diagrams illustrating the results of the inquiry. Excerpts from the report are appended

The lamp, an essential part of the miner's equipment, is used fundamentally to illuminate the various objects in his immediate vicinity. These may be the "face," a prop, a tool, but whatever they may he it is essential and desirable that they should be observed with the minimum of strain on the eye.

Any object is seen simply by the light which it sends to the eye, and is generally observed in terms of its brightness and colour. Different surfaces may be receiving the same amount of light, but the brightness of the surfaces may be very different. It is this difference in brightness which enables various objects to be clearly distinguished. Obviously the brightness and the colour of an object depends ultimately on the source of light employed. The greater the intensity, that is the candle-power, of the source, whatever type it is, then in general, for the same distance of observation, the greater is the brightness of the object. The colour, however, depends very largely on the type of source used. For example, the light from an oil flame lamp differs from that obtained from an electric lamp.

Colour is unfortunately not a characteristic of mines, but perhaps the colour characteristics of the source plays an important part in determining the visibility of objects, particularly with the comparatively low illuminations in general use.

The spectra due to two lamps, one, an oil lamp of the high candle-power Hailwood type and the other of the type which is known as a high candle-power electric lamp, were examined with a constant deviation spectroscope. The candle-powers of the two lamps were adjusted to approximately the same values, and the flame or the filament in each case was placed at the same distance from the silt in the spectroscope.

It is indicated that the sources of white light have quite different spectra. The oil lamp flame possessing, as it does, greater proportions of the red, orange, yellow and green rays and loss of the blue and violet rays, would be calculated to he more agreeable to the sensitive eyes of a miner, and particularly to a miner suffering with nystagmus.

The intensities or brightness of the luminous hand in various parts of the spectra due to the same two lamps above were compared by means of a simple type of spectrophotometer. This simple method at its best is not one which leads to high accuracy, and the necessarily short distances involved decreases it still mere, but a series of readings indicates that for equal candle-powers the intensity in the red particularly and the orange, yellow and green for the oil lamp is substantially greater than for the electric lamp, while the intensity in the blue and the violet of the oil lamp flame, is very much less than that of the light given by the electric lamp. This perhaps has considerable significance in determining the visibility of objects, particularly under comparatively low illuminations, and with surfaces reflecting light largely in the middle region, that is orange, yellow and green, of the spectrum such as is given by coal faces.

There is a limit to the distance between two illuminated point objects for which the eye is capable of distinguishing them as two separate objects. This is the principle on which the test charts used in sight testing under normal conditions of illumination is based, thus small letters, which have less distance between them, can only be read when viewed from a shorter distance than is necessary for the large letters. On the standard optician's chart alongside each row of letters is marked a distance, and at this distance a normal eye should be able to read the letters distinctly. This type of chart was used to examine the visual acuity (or acuteness of vision) under the illumination from the two types of lamp. Each lamp, in turn, was placed at various distances from the standard optician's chart hung up on the wall of a dark room, thus obtaining a range of intensities of illumination on the chart. The position of the flame of the oil lamp or the filament of the electric lamp was in a line at right angles to the centre of the portion of the chart utilised. All observations were made at a distance of thirteen feet (the maximum distance available in the Investigator's laboratory), with the lamp screened so that no light fell directly on the eyes of the observer, the eye being adapted for the low illumination by remaining in the dark room for ten minutes before making any observations. The results of one set of observations, which is typical of others, showed that with an illumination of 0.9 foot-candle the smallest row of letters (0.2 inch high) can be read with the oil lamp illumination, but only the second smallest row (0.29 inch high) with the electric lamp illumination when the chart is observed from the same distance.

To test the visibility under something like normal mining conditions, two miner's lamps — one was old and very dull black in appearance, the other being considerably brighter, these lamps were not alight — and also two wooden rods were placed side by side against a dull black wall (dull black painted). With the high candle-power electric lamp at a distance away of eight feet, all the outlines of the lamps and rods were visible, but with the oil lamp of the same candle-power and placed at the same distance the outlines of the articles were more distinct, the dull lamp outline being easily distinguished. Repeating with the same high candle-power lamps at eleven feet, the rods and brighter lamp were visible, but not the dull one, when using the electric lamp, whereas with the oil lamp all were visible, the outline of the dull lamp being quite definite.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
McKerracher, D.      


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print