Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

14th September 1935, Page: 69, Column: 1

Signalling Circuits And Magneto-Telephones

Electric Signalling Systems and Telephones in Mines (3d. net, H.M. Stationery Office). For M.D. Circular see this Journal page 260, No. 17, Vol. 45.

Regarding magneto-telephones, Mr. J. A. B. Horsley, in his Report as H.M. Electrical Inspector of Mines, says that there has been considerable activity as the outcome of the publication of Safety Pamphlet No. 8 and the subsequent issue of Mines Department Circular No. 69.* Much remains to be done, however, and with the object of directing further attention to the subject of safe signal and telephone circuits Mr. Horsley has written a short note upon the subject, included as Appendix D in his report, as follows :—

Signalling Circuits. — As bare line wires are generally used, which are bridged to complete the circuit and give a signal, it is necessary to pay attention to sparking on the line as well as to sparking at the trembler contacts of the bell and at the circuit contact of the relay where relays are used. Moreover, bells are commonly connected in parallel and a number of relays may require to be connected in parallel, or in series. It becomes necessary, therefore, to have regard for the source of current, as well as for the instruments and their arrangement in the circuit.

The conditions necessary for safety may be summarised as follows : (i) All bells, or relays, must be of certified type. (ii) Any type of battery may be used provided that one bell, or relay, only is included in any one circuit. (iii) Any number of bells, or relays, may be connected in parallel, or in series, with one battery, of approved type, only in the circuit. (iv) Any number of bells, or relays, may be connected in series with two batteries, of approved type, connected in opposition in the circuit.

A certified type of bell or relay means one that has been certified as intrinsically safe.

An approved battery means a battery of not more than 16, 3-pint, porous pot Leclanche cells connected in simple series.

Other types of battery may be approved, e.g., dry cells, if sufficient artificial resistance is added in the construction of the battery to limit the output to the necessary extent.

Up to the time of writing no other source of direct current, such as rectified alternating current, or a motor generator, has been approved as a substitute for a battery for use with certified signalling bells or relays.

So far, no safe signalling system using alternating current, without rectification, has been proposed for the Mines Department Certificate.

Magneto-telephones. — In this case the solution is more complicated because there is no standardised source of current, for the electrical characteristics of the magneto generators differ materially, and, moreover, it is necessary to take account of surface telephone installations and external telephone systems, e.g., Post Office telephones, which may be coupled with the circuits in the mine.

Three alternative solutions of the problem have been suggested these are (i) To isolate the mine circuits electrically from all surface lines and to use certified instruments only in the mine. (ii) To make provision at a manually operated switchboard whereby through speaking is possible between surface lines and the mine, but through ringing is excluded. (iii). To rely on flameproof enclosure of instruments and armoured cable in the danger zone in the mine.

The limitations in convenience of the first solution are obvious, but it may suffice for isolated mines. It involves, however, replacement of all uncertified instruments in the mine installation. The second solution, while permitting direct communication with surface lines, is no less expensive in requiring replacement of all existing uncertified instruments in the mine.

The last solution places no restriction upon the type of instrument, nor upon class of wiring, outside the danger zone, and therefore offers no obstacle to free communication with other telephone systems upon the surface. In many instances this solution will probably meet the practical needs for safety with the least outlay and disturbance.

In this note certified instruments mean instruments that have been certified as intrinsically safe by the Mines Department, and with regard to this a word of warning is necessary. In order that different types of certified instruments may be connected together in the same installation it is necessary to have a condenser of the appropriate capacity connected in shunt with the bell at each instrument.

The addition of the condenser will not make an installation safe which includes any uncertified magneto-telephones. The condenser is merely a device permitting the mixing of different types of certified magneto-telephones in one system.

In magneto-telephones with polarised bells there is no sparking contact on the bell but sparking may occur on the lines, where hare line wires are used, or at terminal connections, and sparking is a normal condition of use at the line switching contacts in the instrument. Hence the need either for intrinsic safety, or, in the alternative, the adoption of the principle of flameproof enclosure.

As magneto-telephone generators are more dangerous when generating current in series, the instruments should be connected in parallel circuits.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Horsley, James Arthur Bennett    H.M. Electrical Inspector of Mines  Whos Who Page


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print