|
16th March 1935, Page: 276, Column: 1 Concealed Dykes And IntrusionsIntroducing their paper on "Magnetic Observations on Concealed Dykes and Other Intrusions in the Northumberland Coalfield," presented at the February meeting of the North of England Institute of Mining and Mechanical Engineers, Professor Granville Poole, B.Sc., J. T. Whetton, M.C., B.Sc., and A. Taylor, B.Sc., say that iron-ore deposits, rich in magnetite, ilmenite, pyrrhotite or some other strongly magnetic mineral, have for many years been located by magnetic methods. The range of detection of ore-bodies is limited by the sensitivity of the detecting apparatus, and as it is probable that many ores usually termed non-magnetic are in reality slightly magnetic, it is quite feasible, with further improvements in magnetic instruments and favourable conditions as to extent of ore-body and depth of cover, that much more successful prospecting will be done in the future. Igneous intrusions can be detected with something akin to certainty providing, of course, that the cover of drift or subsoil is not too great in comparison with the particular mass in question. As regards the location of faults, there is a great degree of uncertainty, but as resistivity methods elucidate this type of problem, the Authors say such failure by the magnetic method is of little importance. Location by this means rests on the difference in magnetic characteristics obtaining on either side of the fault or in the fault plane. As the iron-content of the average Coal Measure strata is extremely small the probable difference is of a very low order, and the question is again one of the sensitivity of the instrument. At present in the average case the variometer will not register these minute differences with sufficient accuracy. Eight magnetic traverses, however, were carried out over five different faults in the coalfields. the Ninety Fathom Fault, the Stakeford Fault, the 30-Fathom Fault in the Choppington area, the New Moor Fault and an un-named one farther north. In no case were the results satisfactory without the bias of foreknowledge; more often than not the vagaries of the instrument obtained by various checks were of the same magnitude as the variations recorded, thus rendering the results worthless. It was expected that the first-named fault more particularly would give slight indications on account of it bringing limestone and coal-measure strata together, but nothing definite could be established. There are, of course, cases where a fault will bring into juxtaposition rocks of very different magnetic qualities, but these are not common in the coalfields. At a later stage in the paper the Authors give a description of a magnetic survey which definitely disclosed a fault, but its location was made possible by the existence of an igneous stratum. It has been shown, they proceed to say, that the Coley Hill Dyke gave magnetic indications, thereby confirming the results given by the resistivity method. As a matter of fact, the magnetic method is much the better one for this particular work, although where a fair depth of drift exists, more care is necessary since the anomalies are smaller. There are so many factors which can affect the resistivity of a section that sometimes a large amount of geological evidence must be known in order to interpret correctly. For example, in the light of further experience it is now fairly certain that the Coley Hill Dyke in the particular part investigated by the resistivity method was traced not by the dyke material itself but by the cinder coal along its edges, and near the surface. To the east a fault intervenes and different electrical indications are given. Traverses carried out recently give maxima of wide extent over the continuation of the dyke east of the fault-line after a northward displacement of some hundreds of feet, the position again corresponding with that met with in the workings below. Evidently in this vicinity such cinder coal as there may be lies at much greater depth. On the other hand, there is nothing of the problematical about magnetic indications. The main purpose of the Authors' investigations was to trace these dykes, for all practical purposes unknown, and this being successful, the usefulness of the magnetic variometer is further established. Many dykes, they add, such as these particular ones, sills, and other igneous intrusions, cut across the Coal Measures in the North of England and more particularly in certain parts of Scotland, which country in addition has to contend with an excess of huge faults. The accurate determination of the positions and general trend of these abnormalities must be of immense value to the mining engineers of such districts, more particularly in virgin or little-worked areas. The magnitude of the anomalies given by any dyke in any one locality seems to be dependent on the following factors (a) Its chemical composition, or, more briefly, its magnetic-content. (b) The depth of cover. (c) The hade (the direction and degree of hade). (d) The thickness and vertical extent of the dyke.
|
|||||||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||