Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

10th November 1934, Page: 131, Column: 2

The Correlation Of Coal Seams

At a meeting on the 27th October of the North of England Institute of Mining and Mechanical Engineers a paper was read by Dr. Arthur Raistrick, Ph.D., M.Sc., F.G.S., on "The Correlation of Coal Seams by Microspore Content (Part 1 The Seams of Northumberland)." Pointing out that the collection and particularly the storing of complete seam pillars of a variety of coals present a difficult problem when many scores of coals are being examined, the author said a direct comparison was made between the results obtained from the examination of the microspore content of a seam, in preparations made from a pillar, and from a channel sample from each of four different seams. After repeated experiments it seems clear that for general correlation purposes, a channel sample of a seam is sufficiently reliable. In collecting a channel sample, a channel is cut down the cleaned face of the seam, about 2 in. wide and of uniform depth, using a sharpened hammer point, to give about 3 to 6 lb. weight of fine coal chippings, according to the thickness of the seam. These chippings are pounded till the whole mass has passed through a 10-mesh sieve. This bulk sample is quartered down until about 4 oz. of average coal are obtained. This is pounded carefully and frequently shaken on a 50 or 60-mesh sieve until all has just passed through. This coal is used for the microspore separations. Trial of various grades of grinding from 30 to 90-mesh indicate that 50 to 60 is the best size for the reactions involved, and is large enough in comparison with the actual microspore sizes to prevent excessive breakage of the spores. With coal ground to 70-mesh, as much as 50 per cent. of all the spore-content may be broken, but with 50 to 60-mesh, the broken material is very small, So long as the methods of grinding, sampling, and treatment are kept strictly the same for all samples, the separations will have the same value for comparison, and the small proportion of broken material can be neglected. For future reference it is useful to keep a sample of the average coal, and for this purpose 2-oz. square tins with fairly tight lids have been found very suitable. As the first part of the treatment consists of oxidation of the coal, there is no need to attempt airtight containers for the samples.

If the microspore-content of coals is to be used for correlation purposes, then two conditions must be fulfilled: (a) the microspore-content of the coal of different seams must be sufficiently different in its proportions for the seams to be distinguished from one another, and to be recognisable by definite characteristics of the microspore assemblage; and (b) the characteristics of each seam must be recognisably constant over a wide area, comparable to the area of the coalfield.

It is suggested that for general correlation work it is first necessary in any coalfield to establish the vertical succession of seam diagrams in several places where the correlations are known, building up a complete succession in collieries as close as possible. This vertical column will give a standard of reference with which any group of seams in that part of the field may be compared, while a few of the wider worked coals will serve to link it with similar columns in other areas. Valuable additions to the knowledge and ease of recognition of individual seams will probably be obtained from the detailed examination of pillar samples of a single seam, and recognition of characteristic bands by spore-content. The examination of one or more seams over a very wide area would provide a valuable datum-line of use in all correlation problems.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Raistrick, Arthur, Dr.      


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print