Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

21st July 1934, Page: 5, Column: 1

An Experimental Gob-Fire Explosion

By T. N. Mason and F. V. Tideswell.

From paper presented on the 13th July at the Buxton Meeting of the Institution of Mining Engineers.

The programme of research on gob-fires which has been undertaken by the Safety in Mines Research Board at their Station at Buxton has for its main object the obtaining of information as to the conditions, during the development and treatment of a fire, most likely to give rise to the danger of gas-explosion. Two S.M.R.B. Papers (Nos. 75 and 76) have been published describing experiments conducted during the years 1927-1931. Paper No. 75 deals with the risk of explosion during the development, and during and after the sealing-off, of a fire; Paper No. 76 with the revival of beatings in a sealed-off area due to inleakage of air. An experiment, No. 15, was designed to include within its scope observations on methods of detecting a heating during its early stages of development. This experiment terminated in an explosion which so damaged the gob-fire chamber as to necessitate its re-construction.

The danger of explosion in a fire area is due, primarily, to the production and accumulation of inflammable gases (a) by distillation from heated coal or coaly dirt, and (b) by evolution of methane from the surrounding strata; and, secondarily, to the ignition by active fire of an inflammable mixture of these gases with air. Running counter to the production of inflammable gases is the removal of oxygen from the air, which proceeds rapidly in a sealed-off area, especially in the neighbourhood of the fire. Once the proportion of the oxygen in the atmosphere has been reduced below about 10 per cent., it is no longer possible for an inflammable gas mixture to be formed. The period of time over which there is danger of explosion in a sealed-off area is therefore usually comparatively short. Other things being equal, the more rapid the reduction of the oxygen in the atmosphere surrounding the fire, the shorter the period of danger; while if the rate of production of inflammable gases is slow compared with the rate of reduction of oxygen, a danger period may never be reached.

The first series of experiments made in the gob-fire chamber, and described in the papers referred to, dealt in turn with (1) coal fires in a goaf, (2) concealed fires in road-side coal-packs, and (3) concealed fires in road-side dirt-packs. They relate only to heatings in non-gassy seams, since it was considered advisable to deal first with the simpler and presumably less dangerous conditions and, from the experience thus gained, to proceed to the more complex conditions arising when firedamp is continuously evolved from the strata surrounding the fire area.

With regard to fires in a goaf, it was shown that a blazing fire in a restricted space is unlikely to create an explosive mixture by the distillation of inflammable gases from the coal, but that most of the gases evolved are burnt at the open fire and help to vitiate the atmosphere to such an extent that an explosion becomes impossible. Nevertheless, it is conceivable that in an extensive goaf, particularly it the fire is in a shielded position, gases distilled from heated material nearby the active fire might form a considerable volume of explosive mixture that could in time extend to the fire and be ignited there, before the oxygen-content of the atmosphere had been so reduced as to render the propagation of flame impossible. It may be anticipated that any evolution of firedamp from the strata would greatly increase this risk.

With active fires concealed in road-side packs it was shown that the possibility of formation of an explosive mixture may arise during the development of a fire, if the evolution of inflammable gases from the heated material is large in comparison with the ventilation of the waste in which these gases may accumulate. The probability becomes greater if for any reason the ventilation is restricted, and is at its height during and immediately after sealing-off, when inflammable gases are distilled freely from the heated carbonaceous material and the atmosphere has not yet become sufficiently vitiated by the products of combustion. With a fire of small size in comparison with the area sealed-off it may be many hours before an explosive mixture can be formed; or, in the absence of firedamp, it may never be formed. With a more advanced, but concealed, fire, the whole sequence of events is hastened.

Fortunately, the presence of an inflammable mixture surrounding the fire does not necessarily mean that a dangerous explosion must ensue, nor even that an ignition will occur. On a number of occasions, during the experimental work, the goat atmosphere remained inflammable for many days without ignition occurring although the only barrier to ignition was a layer of pack-dirt little more than 1 ft. thick. On the other hand, on one of the few occasions on which an inflammable atmosphere was obtained before sealing-off was attempted, an explosion occurred almost immediately.

It is probable that the quiescent state of the atmosphere in a sealed-off area is not conducive to its ignition. Nevertheless the danger of ignition must always exist. This was demonstrated by the succeeding experiment when, under almost similar conditions to those of earlier experiments, an inflammable atmosphere, produced by a concealed lire in a coal-pack, ignited shortly after sealing-off, causing a violent explosion. This experiment, No. 15, was designed with a dual purpose: (1) To observe the sequence of events during the slow heating up of coal in a leaky road-side pack. This was the first attempt made in the gob-fire chamber to induce a heating by spontaneous combustion, all previous fires having been started directly by the use of glowing coke or an electric heater ; (2) To record the changes in composition of the atmosphere in the goaf immediately after sealing-off.

It should be instructive to compare the experimental with practical conditions so that the deficiencies of the experimental arrangement may be fully realised. The coal in a gob, before gaining any heat by oxidation, possesses the comparatively high temperature of, say, between 80° and 90°F., and is enclosed in material of good heat-insulating quality maintained at a similar temperature. Air leaking through the gob usually has a long path to traverse and so becomes heated to the strata temperature by direct conduction; in addition, it gains heat by the exothermic process of oxidation which is continuously proceeding. Fresh surfaces of coal are exposed to this air by fracture induced by roof pressure, and the process of oxidation is thus accelerated. Even under these favourable conditions, however, an incubation period of several months elapses before signs of heating occur. Turning to the conditions in the experimental chamber, it will be obvious that they were much less favourable to the inception of heating. The starting temperature of the coal was about 50°F. (the temperature of the surrounding air), and the pack was of small dimensions. The warm air entering the pack would rapidly lose its heat by conduction, and in its path would encounter only cold coal surfaces that had already undergone partial oxidation during transportation to the Research Station. In the experimental pack, therefore, a small area of coal situated near the point of entry of the air-stream constituted the only possible locus for the development of spontaneous heating. In a gob, many such loci exist temporarily until the ground becomes completely consolidated by roof pressure.

[To be Concluded.]


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Mason, T. N.    Safety in Mines Research Board  
Tideswell, Frederick Vincent    Safety in Mines Research Board  Whos Who Page


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print