Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

23rd June 1934, Page: 392, Column: 1

Lighting In And About Mines

In reply to questions in the House of Commons, Mr. Ernest Brown, Secretary for Mines, said the new code of regulations for mine lighting was formally made on the 1st of June, and would be published with an explanatory memorandum. This has now been done, and the following extracts are from the memorandum (M.D. Circular No. 71):

Explanatory Memorandum.

The Regulations, which apply to all mines under the Act, are in the same terms as the draft issued with the Mines Department Circular of 30th April, 1984. The principal features of the new Regulations may be summarised as follows, but this summary does not obviate the need for a careful study of the Regulations themselves, which are obtainable, 2d. net, through H.M. Stationery Office.

Part I. — Persons wholly or mainly employed at the working face, or at face rippings, or at places where tubs are mechanically filled, must be provided with safety-lamps of types which, when new, satisfy certain requirements as regards their lighting performance, in addition to being approved as regards safety as in the past. This requirement applies to all mines or parts of mines in which safety-lamps are used, and there are only two exceptions: (i.) In respect of places where, in addition to the safety-lamps carried and used by the persons employed, other means of lighting are provided, e.g., compressed-air lamps, mains lighting (where specially permitted) or additional safety-lamps hung up as a means of general lighting. In such circumstances the safety-lamps carried and used by the persons employed need not comply with the new requirements if the Divisional Inspector is satisfied that the actual lighting of the place is as good as it would be if only lamps complying with the new requirements were used. (ii.) If a workman is provided with two lamps — one being primarily for lighting and the other primarily a gas detector, the new requirements do not apply to the second lamp.

Steps are being taken to draw up a list (to be known as the Lighting Schedule) of the safety-lamps which are officially approved as satisfying the requirements of the new regulations, and, in respect of electric safety-lamps to be included in this list, to draw up a complementary list of approved bulbs. The necessary testing arrangements and equipment are already completed: testing will be commenced immediately the lamps and bulbs are submitted by the manufacturers for approval, and lists of approved lamps and bulbs will be published as soon as possible.

A further important provision of Part I. of the Regulations is the requirement that the safety-lamps to which it applies, i.e., lamps in the new Lighting Schedule, must be maintained and used in such a manner that their lighting performance will not deteriorate unreasonably in service. Compliance with this requirement will be primarily a matter of having a properly equipped and organised lamp-room, and of intelligence and care on the part of the lamproom staff in the cleaning, maintenance and repair of the lamps. It is clear that the standard already maintained in this respect at the better organised lamp-rooms — and without any serious difficulty or expense — is far in advance of the standard at a considerable number of mines, where, under existing conditions, the deterioration in the lighting power of the lamps used is excessive and unreasonable and where, therefore, energetic measures will have to be taken to comply with the new requirement.

Part II. — In safety-lamp mines, the use of fixed lights fed by current from the electric mains has hitherto been restricted to the area defined by No. 78 of the General Regulations dated 10th July, 1913, except in a relatively small number of mines for which the use of mains lighting nearer the face has been permitted by special regulations. [These special regulations will remain in force until individually revoked (Regulation No. 9.)] The area is now extended in roads ventilated by intake air up to 50 yards from the working face, and in other roads up to 100 yards from the working face.

In respect of the area previously covered by General Regulation 78, and now covered (without change) by paragraphs (a) and (b) of Regulation 11, the only new requirements imposed by the present Regulations are that the pressure in the lighting system shall not exceed 125 volts, and that the neutral or mid-voltage point of the lighting system, as the case may be, shall be earthed. These requirements do not apply to lighting in this area by direct-current at any mine in which such lighting was installed on the 31st May, 1934.

As regards the new area defined in paragraph (c) of Regulation 11, in which mains lighting is now generally permitted for the first time, the following additional requirements apply: (i.) Mains lighting must not be installed in any ventilating district without the written permission of the Divisional Inspector, unless in that district electric power is already lawfully in use at the working face. (ii.) If in any ventilating district electric power is already lawfully in use at the working face, it is sufficient for notice of the installation of mains lighting in the district to be sent forthwith to the Divisional Inspector. (iii.) All electrical apparatus installed or used for mains lighting in the new area must be of a type approved by the Board of Trade.

Wherever considerations of safety permit, proposals to use mains lighting further inbye than the area covered by paragraph (c) of Regulation 11 will be considered on their merits. Special Regulations will be necessary in such instances for each mine.

Fixed electric lighting from a source of current within the lighting fitting, such for example as the compressed-air lamp, will be permitted within such limits and subject to such conditions as the Board of Trade may determine. A notice on this subject will be published shortly.

Part III. — Sufficient and suitable lighting must be provided in all places on the surface where persons regularly work, and, underground, at shaft insets and shaft sidings. In addition, except on proof by the manager that the natural conditions render it not reasonably practicable, certain important places underground, such as sidings, landings, passbyes, offtakes, and rooms containing engines, motors, or electrical apparatus, must be kept effectively whitewashed.

The New General Regulations.

For students' reference, the new regulations governing lighting in and about mines are given, as follows :—

PART I. LIGHTING BY MEANS OF SAFETY-LAMPS. — (1) In any mine or part of a mine in which safety-lamps are used, the safety-lamps used by persons wholly or mainly employed at the working face, at face rippings, or at any place where tubs are mechanically filled, shall be of a type approved by the Board of Trade, as complying, when new, with the minimum standard of lighting prescribed in the First Schedule hereto under the standard test conditions referred to therein. (2) The safety-lamps to which these regulations apply shall be marked in the manner prescribed by the Board of Trade. (3) The safety-lamps to which these regulations apply shall be maintained and used in such manner as to secure their lighting performance in service against an unreasonable rate or extent of deterioration. (4) The bulbs used in the electric safety-lamps to which these regulations apply shall be of a type approved by the Board of Trade, and for each type of safety-lamp there shall be used only a bulb of the appropriate rated voltage, amperes and efficiency for use with that type of lamp. The bulbs shall be marked in the manner prescribed in the Second Schedule hereto or in such other manner as the Board of Trade may from time to time prescribe. (5) Nothing in Part I. of these regulations shall apply (i.) to the safety-lamps used at any place in respect of which the Inspector or the Division is satisfied that, by the provision of other means of lighting, the lighting is at least equivalent to that which would be provided by safety-lamps complying with the minimum standard of lighting hereinafter prescribed, provided that if the manager disputes the reasonableness of the decision of the Inspector of the Division, the dispute shall be settled in manner provided by the Coal Mines Act, 1911, for settling disputes; (ii.) to any safety-lamp which primarily is provided and used for the purpose of testing for gas, or such other purpose not being lighting as the Board of Trade may prescribe.

(6) This part of the regulations shall come into force on 1st September, 1934, provided that any safety lamp lawfully used on or before that date may continue to be used until 31st December, 1986.

PART II. — LIGHTING OTHERWISE THAN BY MEANS OF SAFETY-LAMPS. — (7) In Section 32 of the Coal Mines Act, 1911 (hereinafter called the Act), for the first proviso to sub-section (1), the following provision shall be substituted: "there may be used in such parts of the mine as the regulations of the mine may permit such means of lighting other than locked safety-lamps as may be permitted by General Regulations made under this Act." (8) Regulation 78 and paragraph (iv.) of Regulation 132 of the General Regulations dated the 10th day of July, 1913, are hereby revoked. (9) Nothing in No. 7 or No. S of these regulations shall affect any special regulation in respect of lighting otherwise than by means of safety-lamps which is in force at any mine at the commencement of those regulations, but such special regulation shall have effect until revoked, as if it formed part of the regulations of the mine. (10) Numbers 11, 12 and 13 of these regulations shall apply to all mines or parts of mines in which safety-lamps are required by the Act or the regulations of the mine to be used. (11) Subject always to the provisions of the Act and of the regulations made thereunder as to the use of electricity in mines, electric lighting from a source of electric power external to the lighting unit may be used (a) on roads ventilated by intake air, but, except as hereinafter provided, not within 300 yards of the nearest working face; (b) on main return airways within 300 yards of the upcast shaft if that shaft is regularly used for the purpose of winding persons, or minerals, but, except as hereinafter provided, not within 300 yards of the nearest working face; (c) on roads ventilated by intake air except within 50 yards, and on other roads except within 100 yards, of the nearest working face (i) in any ventilating district in which electric power is lawfully in use at the working face. Notice of the introduction of electric lighting under this provision shall be sent forthwith to the Inspector of the Division; and (ii.) in any other ventilating district only with the permission in writing of the Inspector of the Division; (d) in any other place in the mine in which its use may be permitted by special regulation.

(12) The use of electric lighting from a source or electric power external to the lighting unit is subject to the following requirements, in addition to the requirements of the Act and of the regulations made thereunder as to the use of electricity in mines: (a) The pressure in the system shall not exceed 125 volts; if the system is polyphase the neutral point shall be earthed, and if the system is of any other kind the mid-voltage point shall be earthed; provided that these requirements shall not apply to lighting by direct current in any mine in which such lighting is installed at the date of these regulations except in so far as the lighting extends to a place which is not covered by paragraph (a) or paragraph (b) of Regulation 11. (b) The lamp bulb shall be hermetically sealed, and shall be totally enclosed in a substantial protective fitting. (c) All electric apparatus installed or used for lighting shall be of a type approved by the Board of Trade, except apparatus installed or used in any place which is covered by paragraph (a) or paragraph (b) of Regulation 11 and to which No. 132 of the General Regulations dated the 10th day of July, 1913, does not apply.

(13) The following provision shall apply in respect of electric lighting from a source of electric power enclosed in the lighting unit, to electric lights which are fittings or accessories to machinery or electrical plant (including signalling apparatus), and to any other means of lighting not specifically mentioned in these regulations: There may be used such means of lighting and such types of lighting unit and apparatus as the Board of Trade may approve, within such limits and subject to such conditions, if any, as the Board of Trade may prescribe either generally or in respect of particular mines or classes of mines.

(14) Part II. of these regulations shall come into force on 1st July, 1934.

PART III. GENERAL. — (15) In all mines under the Act effective provision shall be made for securing and maintaining sufficient and suitable lighting: (a) at shaft insets and shaft sidings which are regularly used; and (b) in every place above ground in which persons regularly work. Above ground all windows and skylights of places where persons are regularly employed shall, so far as practicable, be kept clean and free from obstruction.

(16) In all mines under the Act in which the total number of persons employed underground exceeds 10, the roof (or top) and sides of the following places belowground shall be kept effectively whitewashed except in so far as, under adverse conditions, the manager proves that this is not reasonably practicable: (a) Shaft insets and shaft sidings which are regularly used, (b) The top and the bottom of permanent self-acting inclines, (c) Haulage roads at all sidings, landings, passbyes and junctions (offtakes), except within 100 yards of the working face, (d) Rooms and places where engines or motors are installed, and (e) Rooms containing transformers or switchgear. Provided that the Board of Trade may grant exemption from this regulation in respect of any mine or class of mine as regards which the Board is satisfied that the object of the regulation is effectively achieved in some other way.

(17) Part III. of these regulations shall come into force on 1st September, 1934.

(18) These regulations may be cited as the Coal Mines General Regulations (Lighting) 1934.

First Schedule (Regulation 1).

MINIMUM STANDARD OF LIGHTING FOR NEW SAFETY-LAMPS. — (a) The lamp shall give light such that at the end of nine hours continuous burning under the standard conditions of test the mean spherical candle-power shall not be less than 0.4 for caplamps and 0.75 for all other types of lamp, and the mean candle-power over the horizontal angle of distribution shall not be less than 1.5. (b) The light shall be sufficiently and suitably distributed, without giving rise to glare, and, as far as practicable, without marked contrasts of light and shade within the area of distribution. (c) The standard conditions of test shall be determined and published by the Board of Trade, and shall include for the testing of electric safety-lamps the use of a bulb of the appropriate rated voltage, amperes and efficiency for the type of lamp under test.

Second Schedule (Regulation 4).

MARKING OF BULBS OF APPROVED TYPE. — Every bulb of a type approved by the Board of Trade in pursuance of Regulation 4 shall be indelibly and distinctly marked on the cap with the following marking:

(i.) The manufacturer's name and/or trade mark.

(ii.) The rated voltage and rated amperes of the type.

(iii.) The outline of a crown with the letters MDS therein.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Brown, Alfred Ernest    Secretary for Mines  Whos Who Page


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print