Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

22nd March 1930, Page: 288, Column: 2

Links Between Socket And Cage Chains

At the meeting of the North of England Institute of Mining and Mechanical Engineers on the 22nd of February, Mr. Charles Howson submitted a paper on "Notes on a Winding Accident at Mainsforth Colliery, 31st December, 1928." He said in the course of his paper that the "accident was due to the failure of a link connecting the shackle of the rope socket to the shackle of the detaching hook. The ascending cage, fully loaded with four tubs of coal, fell about 30 fathoms to the pit bottom. The link that failed had been in use for some years and had been annealed a few days before the mishap. It was made of iron 2¾ inches in diameter, and as the dead load on it was 10.1 tons it was expected to have a sufficiently high factor of safety. A thorough investigation of the cause of the failure with a view to the prevention of a similar accident was made, and a series of tests of links and shackles of the sizes in use at the colliery was also made. The fractured ends of the link that failed revealed a defective weld for nearly 50 per cent. of the sectional area, but the defect was in such a position that it was impossible to see it when the link was heated up in the annealing furnace. The fact that such a weakness could exist in a link which was, as far as could be seen, thoroughly sound, made it obvious that the use of any links at all between the socket and the cage chains is undesirable, and their use has been dispensed with at Mainsforth Colliery." Mr. Howson gave the results of some tests and concluded by saying that "the failure in question and the subsequent tests force one to the conclusion that welded links unless used in multiples are untrustworthy."


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Howson, Charles      Whos Who Page



Links to Collieries/Mines mentioned in this article

 

Mainsforth Colliery  Mainsforth Colliery


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print