5th October 1929, Page: 88, Column: 1
Wire For Mining Ropes
At the autumn meeting in Newcastle
of the Iron and Steel Institute, Mr. A. T. Adam presented a paper
on "Notes on Wire for Mining Ropes," the conclusions arrived at
being : It is considered that the cold-drawn condition is the most
satisfactory one for rope wire, and that the internally-stressed state
and fibrous structure produced by drawing are not objectionable,
but beneficial. Further evidence has been given of the advantage
of lead-cooling in patenting, and it is suggested that the best rope
wire is made by selecting a steel of the lowest carbon content
consistent with the tensile strength desired, making the greatest use
of the carbon by lead-quenching, and giving the wire a total reduction
of area of between 50 and 80 per cent., according to the
diameter, carbon content, quality of steel, and reduction per pass;
the better the quality of steel, the lower the carbon, and the easier
the stages of reduction the greater the total reduction may be.
It has been indicated that a definite stage in drawing is reached
beyond which no rope wire should be drawn. This is indicated by
an abrupt change in the increase in tensile strength. Although
torsions and contraction of area roughly indicate this same stage,
they do not do so with sufficient accuracy to be of use in practice,
and some simple test to determine whether a wire has been overdrawn
is desirable. To some extent this can be determined by
comparing the tensile strength of the finished wire with the composition
and quality of the steel. It is finally submitted that the
general behaviour of ropes constructed of cold-drawn wire throughout
the past years affords support to the above conclusions.
 |
 |
|