|
13th July 1929, Page: 407, Column: 1 Electric Cap LampsCaptain C. B. Platt, superintending testing officer, and Mr. G. A. Culter, analyst, have reported to the Mines Department "On an investigation at the Mines' Department Testing Station, Sheffield, of the safety of miners' electric cap lamps When the battery is short-circuited." (2d. net, H.M. Stationery Office.) They say that in view of the increasing extent to which miners' electric cap lamps are being taken into use in fiery mines in this country, it has been considered desirable to investigate the possibility, which is peculiar to this type of safety-lamp, of danger arising from short circuit-sparking at a fault in the flexible cable connecting the headpiece of the lamp to the battery container. This cable consists usually of two conductors, each composed of many strands of fine copper wire ; each conductor is separately insulated, usually with a layer of cotton over which is placed a coating of vulcanised rubber, over which is again a further layer of cotton. The two conductors are then twisted together and enclosed in a cab tyre sheath. In some instances the strength of the two conductors is reinforced by a cotton core. It will be seen that if the cab tyre sheath becomes defective and ceases to protect the conductors, the insulation of each of these, being of a relatively delicate nature, is easily damaged ; and that if the insulation on both becomes faulty a short circuit of the battery may result. In order to determine the nature of the damage actually sustained by these cables under ordinary working conditions, a large number of sample discarded cables were obtained from collieries at which electric cap lamps were in use. Of these cables 20 per cent. were damaged to such an extent as to expose both the conductors, and in many instances the rubber sheathing in the vicinity of the fault had perished and lost its natural protective properties. It was also observed that cables which were defective in this particular respect had been repaired for further service by covering the damaged sheathing with insulating tape, a practice which is of questionable value, in view of the ease with which, under working conditions, a cable so repaired can again be rendered defective. In the description of the experiments carried out the Authors' point out that in addition to the danger to be apprehended from the direct ignition of gas by the short-circuit of a cap lamp cable, there is also the possibility of the inflammation of the cotton insulation which may smoulder or burst into flame when it comes into contact with the short-circuited and heated wires. That such is the case was proved by experiment. The time required to ignite the cotton strands in this manner is, however, fortuitous and indeterminate. It is considered, however, that the production of smouldering or burning cotton in this manner is likely to occupy, at least, several seconds. If, therefore, the circuit could be broken in a sufficiently short interval of time no direct ignition of firedamp, or combustion of the cotton insulation, could occur. A simple method of doing this is to interpose a fuse between the battery and the cable. Such a fuse to be effective in practice must have the following characteristics: (a) Simplicity of design; (b) reliability; (c) a short fusing period. The most convenient form of fuse is the cartridge type in which the wire is enclosed in a tube of insulating material provided with a metal cap at each end ; a fuse of this type can easily be held in a spring clip, and it can be made sufficiently small to occupy an inappreciable space in the lid of the battery case. The majority o£ the makes of cap lamp already approved could, without difficulty, be fitted with a fuse of this design. Other forms of enclosed fuse, not necessarily tubular but operating oa the same principle, will no doubt suggest themselves. The conclusion of the Authors is that the danger to be apprehended from a short-circuited cap lamp battery is probably very remote. Nevertheless, the provision of an adequately designed fuse — a simple and inexpensive matter — would eliminate any possibility of an accident due to this cause.
|
|||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||