Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

13th July 1929, Page: 401, Column: 1

Spontaneous Combustion

The subject of a paper before the June meeting of the North Staffordshire Institute of Mining Engineers was Spontaneous' Combustion in North Staffordshire, being Part II., A Record of Analysis of Air-samples taken during the Combating of a Gob-fire. The paper was presented by T. David Jones, Ph.D., M.Sc., of the Mining Research Laboratory, University of Birmingham. In the case under consideration a fire had occurred in a district in the Yard Seam (longwall working), and it was decided to follow the sealing-off operations by frequent analysis of the vitiated air in order to ascertain the variation of the CO2/O2, and CO/O2 figures, especially the latter, and, if possible, to correlate this variation with the disappearance of gob-stink. In the district in which the fire occurred the face was 170 yards long, with a dip of 1 in 4, the intake and main haulage-road being at the bottom and the return at the top end. Halfway along the face a middle level was packed In, the object being to facilitate the bringing of dirt and materials lo the coal face. The intake, middle, and return levels are supported by 12-yard packs, and the gob between these is made up of 4 to 5-yard dirt packs, with intermediate wastes of at least 8 yards (the distance depending upon the roof conditions). At the time of the outbreak of the fire, the upper section of the face, i.e., all above the middle level, had reached the boundary of the shaft pillar. On reaching the boundary, a 4-yard dirt pack was built along the face and a 7-yard pack put along the gob side, leaving an airway of at least 6 feet between the two packs. Occasional wood chocks were built in on the outside of the 7-yard pack. The section of the Yard Seam at this colliery is as follows :— Top coal 2 feet 6 inches ; dirt 3 inches ; bottom coal 3 feet 9 inches. Generally, a thickness of 15 inches of the top coal is left in the gob over the packs, but in this district, owing to the bad condition of the roof and the fact that the top coal was thicker than usual, the average thickness of coal left in was 2 feet 3 inches.

The Outbreak of Fire. — So far as could be ascertained, no indications of heating had been noticed prior to the discovery of the fire. The latter was discovered by the fireman at 7-30 p.m. on January 2nd, 1927, during his inspection before the commencement of the Sunday-night shift. On entering the district by the return, an unusual (smoky) smell was noticed, which was traced to the return of the district in question. On following the smell to the face, smoke was found to be exuding from the 7-yard pack on the gob aide of the airway. A brattice sheet had been erected on the return side of this point to act as a regulator. Apart from serving its purpose as a regulator, the sheet diverted the air through the 7-yard pack and on to the gob behind. It is thought that this sheet at least accelerated the fire if it was not wholly responsible for it. Unfortunately the author was not informed of the occurrence until the morning of January 7th, by which time the intake and return stoppings had been erected and were being strengthened. There was a definite and strong gob-stink issuing from the return stopping on January 7th, and a series of air samples were taken periodically at the various stations. As a result of a previous investigation in the Yard Seam at this colliery, it was found that the normal CO/02 figure was 0.5 per cent. with a CO2/O2 figure of 30 per cent. The CO/O2 figure for a sample taken in the return of this district on October 7th, 1926, was 0.35 per cent., and the CO2/O2 figure was 55 per cent.

For the purposes of ventilation, doors were placed at the bottom of the stand jig, and since the erection of the intake stopping the middle level was used as a return airway for the bottom section of the face. It was decided, therefore, to ascertain the difference in pressure between the intake and return stoppings. Two aneroid barometers were used for this purpose, one being 6 inches in diameter and sensitive to 0.002 inch of mercury, and the other 2½ inches in diameter and sensitive to 0.02 inch of mercury. The latter was used at a point approximately halfway between the two stations, in order to detect any barometric variation which might occur during the carrying out of the test. The 6-inch aneroid barometer was used for obtaining the pressures at the intake and return stoppings respectively. The first test carried out on January 13th, 1927, showed a difference amounting to 0.55 inch of water. Following this test, the management immediately short-circuited a large quantity of air by partly opening the doors at the bottom of the stand jig. It was decided to carry out another test after a short while (about 1½ hours after the first test). The second test showed that the pressure-difference had now been reduced to 0.35 inch of water. It was then decided to remove the doors altogether and replace them by a brattice sheet, A further test was carried out on January 18th, and it was found that the difference in pressure was practically nil. On January 20th still another test was made, which revealed that a state of balance had now been obtained between the two stoppings.

From the time when this satisfactory state of affairs was obtained, namely, January 13th, the CO/O2 as well as the CO2/O2 figures became gradually lower. Whilst following the development of heatings, it has been found in this coalfield that gob-stink has been detected when the CO/O2 figure has been 3 per cent. But the gob-stink in this case did not disappear until the CO/O2 figure had been reduced to about 1 per cent. The difference between these two figures is due possibly to the absorption of the gob-stink odour by the surrounding materials. It is surprising how long certain odours persist, and especially so in underground workings. Definite gob-stink remained for a whole month after the occurrence of the fire.

Heating of Sand used for Stoppings. — Whilst carrying out the work referred to in this paper, an instance of sand having heated of its own accord was brought to notice. Sand had been used to fill up the gaps in the pack-walls on the return level, since gas from the affected area had been leaking out of the point in question. The men working at the return stopping reported that the sand which they had put in the day before was quite hot. On inspection the temperature of the sand was over 20°Fahr. higher than the air temperature. It was decided to fill out the sand and replace it with stone dust. When the sand was cleaned up, it was found that the temperature at the pack-wall was quite normal. It could not, therefore, be a case of the slightly damp sand conducting the heat from the affected area ; in fact, the temperatures along the return level and at all points were quite normal. After a few days the stone dust was examined, there being no change in temperature. The author is of the opinion that stone dust is preferable to sand in the construction of stoppings and the sealing-off of fires.

The Use of an Aneroid Barometer in Collieries. — There is great scope for the use of the aneroid barometer in mines. Not only can it be used for finding difference in levels, and for general levelling purposes, but for calculating the difference in ventilating pressure between points in the same air-circuit.

Conclusions. — The results show that it may take a long time to seal off a fire successfully when no preparatory stoppings are available. In the case under consideration gob-stink seems to have disappeared when the carbon-monoxide/oxygen figure was about 1 per cent. In the case of three other heatings in the North Staffordshire Coalfield, the author has observed that during the development of heating "stink" has not become really evident until the carbon-monoxide/oxygen figure has been about 3 per cent. It would appear, therefore, as if the odoriferous constituents are absorbed during the development stages, and, after the fire has been sealed off, are subsequently and slowly given up to the fresh air.

The aneroid barometer has proved most useful in the present case for ascertaining the pressure-difference between the intake and the return side of the heating. With this information it was possible to equalise the pressure and thus reduce to a minimum the leakage of air through this section of the goaf.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Jones, T. David    Mining Research Laborator  


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print