13th July 1929, Page: 401, Column: 1
Spontaneous Combustion
The subject of a paper before the June meeting of the North Staffordshire
Institute of Mining Engineers was Spontaneous' Combustion in North
Staffordshire, being Part II., A Record of Analysis of Air-samples taken during
the Combating of a Gob-fire. The paper was presented by T. David Jones,
Ph.D., M.Sc., of the Mining Research Laboratory, University of Birmingham. In
the case under consideration a fire had occurred in a district in the Yard Seam
(longwall working), and it was decided to follow the sealing-off operations by
frequent analysis of the vitiated air in order to ascertain the variation of
the CO2/O2, and CO/O2 figures, especially the
latter, and, if possible, to correlate this variation with the disappearance of
gob-stink. In the district in which the fire occurred the face was 170 yards
long, with a dip of 1 in 4, the intake and main haulage-road being at the
bottom and the return at the top end. Halfway along the face a middle level was
packed In, the object being to facilitate the bringing of dirt and materials lo
the coal face. The intake, middle, and return levels are supported by 12-yard
packs, and the gob between these is made up of 4 to 5-yard dirt packs, with
intermediate wastes of at least 8 yards (the distance depending upon the roof
conditions). At the time of the outbreak of the fire, the upper section of the
face, i.e., all above the middle level, had reached the boundary of the shaft
pillar. On reaching the boundary, a 4-yard dirt pack was built along the face
and a 7-yard pack put along the gob side, leaving an airway of at least 6 feet
between the two packs. Occasional wood chocks were built in on the outside of
the 7-yard pack. The section of the Yard Seam at this colliery is as follows
:— Top coal 2 feet 6 inches ; dirt 3 inches ; bottom coal 3 feet 9
inches. Generally, a thickness of 15 inches of the top coal is left in the gob
over the packs, but in this district, owing to the bad condition of the roof
and the fact that the top coal was thicker than usual, the average thickness of
coal left in was 2 feet 3 inches.
The Outbreak of Fire. — So far as could be ascertained, no
indications of heating had been noticed prior to the discovery of the fire. The
latter was discovered by the fireman at 7-30 p.m. on January 2nd, 1927, during
his inspection before the commencement of the Sunday-night shift. On entering
the district by the return, an unusual (smoky) smell was noticed, which was
traced to the return of the district in question. On following the smell to the
face, smoke was found to be exuding from the 7-yard pack on the gob aide of the
airway. A brattice sheet had been erected on the return side of this point to
act as a regulator. Apart from serving its purpose as a regulator, the sheet
diverted the air through the 7-yard pack and on to the gob behind. It is
thought that this sheet at least accelerated the fire if it was not wholly
responsible for it. Unfortunately the author was not informed of the occurrence
until the morning of January 7th, by which time the intake and return stoppings
had been erected and were being strengthened. There was a definite and strong
gob-stink issuing from the return stopping on January 7th, and a series of air
samples were taken periodically at the various stations. As a result of a
previous investigation in the Yard Seam at this colliery, it was found that the
normal CO/02 figure was 0.5 per cent. with a
CO2/O2 figure of 30 per cent. The CO/O2 figure
for a sample taken in the return of this district on October 7th, 1926, was
0.35 per cent., and the CO2/O2 figure was 55 per cent.
For the purposes of ventilation, doors were placed at the bottom of the stand
jig, and since the erection of the intake stopping the middle level was used as
a return airway for the bottom section of the face. It was decided, therefore,
to ascertain the difference in pressure between the intake and return
stoppings. Two aneroid barometers were used for this purpose, one being 6
inches in diameter and sensitive to 0.002 inch of mercury, and the other
2½ inches in diameter and sensitive to 0.02 inch of mercury. The latter
was used at a point approximately halfway between the two stations, in order to
detect any barometric variation which might occur during the carrying out of
the test. The 6-inch aneroid barometer was used for obtaining the pressures at
the intake and return stoppings respectively. The first test carried out on
January 13th, 1927, showed a difference amounting to 0.55 inch of water.
Following this test, the management immediately short-circuited a large
quantity of air by partly opening the doors at the bottom of the stand jig. It
was decided to carry out another test after a short while (about 1½ hours
after the first test). The second test showed that the pressure-difference had
now been reduced to 0.35 inch of water. It was then decided to remove the doors
altogether and replace them by a brattice sheet, A further test was carried out
on January 18th, and it was found that the difference in pressure was
practically nil. On January 20th still another test was made, which revealed
that a state of balance had now been obtained between the two stoppings.
From the time when this satisfactory state of affairs was obtained, namely,
January 13th, the CO/O2 as well as the CO2/O2
figures became gradually lower. Whilst following the development of heatings,
it has been found in this coalfield that gob-stink has been detected when the
CO/O2 figure has been 3 per cent. But the gob-stink in this case did
not disappear until the CO/O2 figure had been reduced to about 1 per
cent. The difference between these two figures is due possibly to the
absorption of the gob-stink odour by the surrounding materials. It is
surprising how long certain odours persist, and especially so in underground
workings. Definite gob-stink remained for a whole month after the occurrence of
the fire.
Heating of Sand used for Stoppings. — Whilst carrying out the work
referred to in this paper, an instance of sand having heated of its own accord
was brought to notice. Sand had been used to fill up the gaps in the pack-walls
on the return level, since gas from the affected area had been leaking out of
the point in question. The men working at the return stopping reported that the
sand which they had put in the day before was quite hot. On inspection the
temperature of the sand was over 20°Fahr. higher than the air temperature.
It was decided to fill out the sand and replace it with stone dust. When the
sand was cleaned up, it was found that the temperature at the pack-wall was
quite normal. It could not, therefore, be a case of the slightly damp sand
conducting the heat from the affected area ; in fact, the temperatures along
the return level and at all points were quite normal. After a few days the
stone dust was examined, there being no change in temperature. The author is of
the opinion that stone dust is preferable to sand in the construction of
stoppings and the sealing-off of fires.
The Use of an Aneroid Barometer in Collieries. — There is great
scope for the use of the aneroid barometer in mines. Not only can it be used
for finding difference in levels, and for general levelling purposes, but for
calculating the difference in ventilating pressure between points in the same
air-circuit.
Conclusions. — The results show that it may take a long time to
seal off a fire successfully when no preparatory stoppings are available. In
the case under consideration gob-stink seems to have disappeared when the
carbon-monoxide/oxygen figure was about 1 per cent. In the case of three other
heatings in the North Staffordshire Coalfield, the author has observed that
during the development of heating "stink" has not become really
evident until the carbon-monoxide/oxygen figure has been about 3 per cent. It
would appear, therefore, as if the odoriferous constituents are absorbed during
the development stages, and, after the fire has been sealed off, are
subsequently and slowly given up to the fresh air.
The aneroid barometer has proved most useful in the present case for
ascertaining the pressure-difference between the intake and the return side of
the heating. With this information it was possible to equalise the pressure and
thus reduce to a minimum the leakage of air through this section of the goaf.
 |
 |
|
Names mentioned in this article
|
 |
 |
| Name | Age | Occupation | Notes |
| Jones, T. David | | Mining Research Laborator | |