6th April 1929, Page: 293, Column: 2
Pulverised Coal
In a paper read before the Institution of Engineers and Shipbuilders in
Scotland, Engineer-Captain J. C. Brand quoted the results obtained by
Mr. W. H. Patchell in a 24-hours' test made on a Lancashire boiler fired
with pulverised coal on the Brand system, The boiler in question was 26 ft.
long and 7 ft. in diameter, and had a heating surface of 778 sq. ft. The volume
of each of its two furnaces was 155 cu. ft., and two Brand turbulent rotary
flame burners were fitted. The air temperature was 36.8°F. and the
feed-water temperature 40°F. The coal, Darton Main slack, had a calorific
value by bomb of 12,902 B.Th.U., and contained 1.81 per cent. of moisture,
29.67 per cent. of volatile matter, 54.88 per cent. of fixed carbon, and 13.64
per cent. of ash. It was pulverised in a No. 8 Herbert Atritor so that 92.4 per
cent. passed a 200 mesh. The power expended in transporting and firing the fuel
was 15.25 kw. hours. The steam pressure was 90.7 lb. per sq. in. abs. The total
coal used was 17,230 lb. and the water evaporated 129,950 lb. The water
evaporated was thus 7.54 lb. per lb. of fuel as fired, and 0.04 lb. per lb. of
fuel from and at 212°F. The gross overall thermal efficiency of the boiler
worked out at 69.02 per cent., the heat lost in the chimney gases amounting to
13.3 per cent., and the radiation and other unaccounted losses to 17.68 per
cent. No superheater or economiser was fitted. Only a light vapour was visible,
and that seldom, and at no time was dark smoke apparent. In the course of his
paper Captain Brand stated that with this type of boiler 16 per cent. of the
infusible ash finds its way up the stack, 40 per cent. lodges just below the
chimney, 20 per cent. in the side flues (the first pass), and 24 per cent. in
the bottom flues.
The possibilities of pulverised coal as a fuel for locomotives, and the
investigations in that direction which have been carried out in Germany were
discussed by Mr. Roosen, chief engineer of Messrs. Henschel and Co.,
Cassel, in a paper read at a meeting of the Institution of Locomotive Engineers
(Scottish Centre). The main reasons, Mr. Roosen said, which made coal
dust firing attractive for locomotive service were the availability of cheap
fuel (such as lignite), which was not suitable for grate firing; the
adaptability of pulverised-coal firing to the ever-varying running conditions,
and the relief afforded to firemen. As coal dust firing was mechanical there
was a complete elimination of fatigue on the part of the firemen. In addition,
the boilers could be built much larger than at present, as hitherto their
capacity was curtailed by consideration of the size of grate area which could
be economically attended by the fireman. It was true that the existing type of
mechanical stokers had solved the problem from an efficiency point of view, but
they did not handle the expensive hard coal with sufficient economy. Discussing
the experiments carried out in Germany, Mr. Roosen said the main task
was to develop a suitable type of burner, and that decided upon was one based
on the principle of subdividing the injected mixture to the greatest possible
extent. By it the dust and air mixture was spread in a number of jets, which
were ignited almost immediately in front of the burner plate, and caused the
formation of a diffused ball-shaped flame. The burner remained cold when in
operation, and the spray plate, which was exposed to radiating heat, was cooled
by the mixture, so that special cooling of the burner was not required. In
describing the locomotives used in Germany for the experiments, Mr.
Roosen said that the former coal bunker or tender was replaced by a
pulverised fuel container, the sides of which were sloping and which was
perfectly closed. The shape of the container favoured the sagging of the coal
dust, and, as it was welded, there were no projecting edges. The locomotives
were tried under varying loads and on lines which had numerous curves and long
inclines of 1 in 100. The weight of the trains was from 1,200 to 1,300 tons,
and the trial runs demonstrated the simplicity of operation and the reliability
of the pulverised fuel-burning equipment. Full steam pressure could be easily
maintained, and there was no difficulty in preventing steam from blowing off
when passing from gradients to level or down grades. The runs were made on
lignite dust, the combustion of which was perfect, and the flue gases emitted
were colourless. No sparking was observed, and even when the engines were
running very slowly there was an unimpeded flow of flue gas. The time for
steaming up a pulverised fuel-burning engine was considerably shorter than that
required in the case of a grate-fired locomotive.
 |
 |
|
Names mentioned in this article
|
 |
 |
| Name | Age | Occupation | Notes |
| Brand, J. C. | | Engineer-Captain | |
| Patchell, W. H. | | | |
| Roosen, — | | | |