Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

6th April 1929, Page: 293, Column: 2

Pulverised Coal

In a paper read before the Institution of Engineers and Shipbuilders in Scotland, Engineer-Captain J. C. Brand quoted the results obtained by Mr. W. H. Patchell in a 24-hours' test made on a Lancashire boiler fired with pulverised coal on the Brand system, The boiler in question was 26 ft. long and 7 ft. in diameter, and had a heating surface of 778 sq. ft. The volume of each of its two furnaces was 155 cu. ft., and two Brand turbulent rotary flame burners were fitted. The air temperature was 36.8°F. and the feed-water temperature 40°F. The coal, Darton Main slack, had a calorific value by bomb of 12,902 B.Th.U., and contained 1.81 per cent. of moisture, 29.67 per cent. of volatile matter, 54.88 per cent. of fixed carbon, and 13.64 per cent. of ash. It was pulverised in a No. 8 Herbert Atritor so that 92.4 per cent. passed a 200 mesh. The power expended in transporting and firing the fuel was 15.25 kw. hours. The steam pressure was 90.7 lb. per sq. in. abs. The total coal used was 17,230 lb. and the water evaporated 129,950 lb. The water evaporated was thus 7.54 lb. per lb. of fuel as fired, and 0.04 lb. per lb. of fuel from and at 212°F. The gross overall thermal efficiency of the boiler worked out at 69.02 per cent., the heat lost in the chimney gases amounting to 13.3 per cent., and the radiation and other unaccounted losses to 17.68 per cent. No superheater or economiser was fitted. Only a light vapour was visible, and that seldom, and at no time was dark smoke apparent. In the course of his paper Captain Brand stated that with this type of boiler 16 per cent. of the infusible ash finds its way up the stack, 40 per cent. lodges just below the chimney, 20 per cent. in the side flues (the first pass), and 24 per cent. in the bottom flues.

The possibilities of pulverised coal as a fuel for locomotives, and the investigations in that direction which have been carried out in Germany were discussed by Mr. Roosen, chief engineer of Messrs. Henschel and Co., Cassel, in a paper read at a meeting of the Institution of Locomotive Engineers (Scottish Centre). The main reasons, Mr. Roosen said, which made coal dust firing attractive for locomotive service were the availability of cheap fuel (such as lignite), which was not suitable for grate firing; the adaptability of pulverised-coal firing to the ever-varying running conditions, and the relief afforded to firemen. As coal dust firing was mechanical there was a complete elimination of fatigue on the part of the firemen. In addition, the boilers could be built much larger than at present, as hitherto their capacity was curtailed by consideration of the size of grate area which could be economically attended by the fireman. It was true that the existing type of mechanical stokers had solved the problem from an efficiency point of view, but they did not handle the expensive hard coal with sufficient economy. Discussing the experiments carried out in Germany, Mr. Roosen said the main task was to develop a suitable type of burner, and that decided upon was one based on the principle of subdividing the injected mixture to the greatest possible extent. By it the dust and air mixture was spread in a number of jets, which were ignited almost immediately in front of the burner plate, and caused the formation of a diffused ball-shaped flame. The burner remained cold when in operation, and the spray plate, which was exposed to radiating heat, was cooled by the mixture, so that special cooling of the burner was not required. In describing the locomotives used in Germany for the experiments, Mr. Roosen said that the former coal bunker or tender was replaced by a pulverised fuel container, the sides of which were sloping and which was perfectly closed. The shape of the container favoured the sagging of the coal dust, and, as it was welded, there were no projecting edges. The locomotives were tried under varying loads and on lines which had numerous curves and long inclines of 1 in 100. The weight of the trains was from 1,200 to 1,300 tons, and the trial runs demonstrated the simplicity of operation and the reliability of the pulverised fuel-burning equipment. Full steam pressure could be easily maintained, and there was no difficulty in preventing steam from blowing off when passing from gradients to level or down grades. The runs were made on lignite dust, the combustion of which was perfect, and the flue gases emitted were colourless. No sparking was observed, and even when the engines were running very slowly there was an unimpeded flow of flue gas. The time for steaming up a pulverised fuel-burning engine was considerably shorter than that required in the case of a grate-fired locomotive.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Brand, J. C.    Engineer-Captain  
Patchell, W. H.      
Roosen, —      


 

mail
Mail:
Webmaster
Back