15th December 1928, Page: 165, Column: 2
Safeguarding Electrical Equipment
Printed by permission of the Director, U.S. Bureau of Mines.
Arising out of the British and American co-operation safety papers are being
issued by the U.S. Bureau of Mines. For instance, Circular No. 6082, by
Mr. L. C. Ilsley, the Bureau Electrical Engineer, deals with British practice
in safeguarding electrical equipment used in gassy mines. He quotes the General
Regulations (119, 125, 131, 132) and says that some of the outstanding features
of the rules that have a chief bearing in maintaining electrical safety are:
(1) Strict rules with respect to giving notice to the Mines Department of
intention of installing new equipment. (2) Strict rules regarding the earthing
(grounding) of all equipment and wiring. (3) Instructions for selection of the
electrician and other workmen with the requirement that the electrician must be
in constant attendance. (4) Requirement that a daily log must be kept of
happenings on electrical apparatus in a prescribed log book. (5) Requirement
that defective equipment be put out of service at once. (6) Special rules
covering the use of electrical equipment and wiring in gassy portions of the
mine to prevent "open sparking."
After remarking that the users and manufacturers of electrical equipment are
taking forward steps to formulate testing procedure for equipment and to meet
the expense entailed in having types of equipment tested, Mr. Ilsley
quotes the British Standard Specifications for Flame-proof Enclosures and for
Testing such Enclosures. He then proceeds : When one considers the rigid
regulations covering electrical equipment in British mines, it would be natural
to think that the protective requirements for gassy parts of a mine would be
especially severe, but this is not necessarily the case. Much of the equipment
used at the face workings has not been tested at Sheffield. The tendency
apparently is to place more emphasis on inspection than on actual tests in
gaseous mixtures. The Bureau of Mines has found in testing a great many outfits
representing the product of several manufacturers that tests are very valuable
in showing unsuspected weaknesses of equipment which might easily be overlooked
or not evident from an inspection.
Upon the question of inspection Mr. Ilsley expresses himself thus : The
electrical inspection work in Great Britain is in the hands of the Divisional,
Assistant, and Junior Mine Inspectors ; in case of an electrical accident or a
difficult electrical problem, these men call on the Chief Electrical Inspector,
who has his headquarters at the Mines Department. The inspection of electrical
equipment is made comparatively easy by the rigid rules governing the
installation of new equipments and the maintenance requirements for all
electrical equipment. There is only one electrical inspector. Greater safety
would undoubtedly result if more electrical equipment was subjected to actual
tests in gas. In addition to the Government inspection, many of the owners
carry out very complete and systematic periodic inspections. One company with
four collieries had a force of 16 electricians and a most elaborate inspection
system.
Comparing electrical equipments in Great Britain and the United States Mr.
Ilsley says : There are a number of differences between electrical
installations in Great Britain and the United States. For instance, in British
coal mines there are no trolley locomotives, whereas statistics compiled for
1924 give 11,986 in the United States. Every piece of apparatus and practically
every conductor in British mines is earthed by carrying a ground conductor to a
ground plate on the surface ; practically no earthing is resorted to in
American mines except to connect frames of stationary motors to a pipe or rail
return within the mine.
Alternating current is not used extensively in American mines, but in British
mines this prevails, and direct-current circuits are being replaced by
alternating-current circuits in a number of mines. The natural conditions in
British mines as to grades, faults, thinness of seams, extreme depth of shafts,
and the difficulty of properly supporting the overburden render the
installation of electrical equipment much more difficult than in American
mines. In regard to electrical safety it can be said without danger of
contradiction that the regulations governing the installation, inspection, and
maintenance of electrical equipment are better in Great Britain than in
America. In regard to the practice of using strictly safe equipment in gassy
sections of mines, there is much yet to be done in both countries.
 |
 |
|