Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

22nd September 1928, Page: 75, Column: 1

Miners' Self-Rescuers

Self-rescuers are pocket-size respirators that protect the wearer from air contaminated with that poisonous gas carbon monoxide. Messrs. S. H. Katz and J. J. Forbes, in Miners' Circular 30 of the U.S. Bureau of Mines. They proceed to say that the purpose of the self-rescuer is to provide a miner with protection from carbon monoxide for at least half an hour and thus help him to escape from a mine in which a Are is burning or an explosion has occurred. Although the self-rescuer does not supply oxygen, it does remove the hazard of carbon monoxide for half an hour or more, and thus greatly increases a miner's chance of getting out alive. Until the self-rescuer is used it is enclosed in a brass case sealed air-tight with soft solder and having a cover that may be ripped off by hand. The case measures 7 by 3 5/6 by 1 13/16 inches outside ; it weighs 21 ounces when it contains the self-rescuer ; the weight of the latter alone is about 13 ounces, and the miner may carry a self-rescuer in his coat pocket or by a belt loop on his belt. It is a small canister made of tin plate, to which a mouthpiece is directly attached. The wearer breathes by mouth and through the self-rescuer ; breathing through the nose is prevented by a pinch clamp or nose clip on the nostrils. When a self-rescuer is put in use the air the wearer breathes, passes through certain essential parts and materials. First, inhaled air enters through small holes in the canister at the lower side and then filters through absorbent cotton, held between wire screens, which removes smoke. Next is a layer of granular (14 to 20 mesh size) fused calcium chloride (90 cubic centimetres or 5½ cubic inches in volume), to absorb water vapour, which is always present in air and destroys the efficiency of the "hopcalite," the material in the next layer. Hopcalite is a granular (14 to 20 mesh size) mixture of specially prepared manganese dioxide and copper oxide ; 110 cubic centimetres (6¾ cubic inches) are put into the canister. This layer is separated from the calcium chloride by wire gauze. Hopcalite acts as a catalyzer, that is, it causes any carbon monoxide (CO) and oxygen (O2) in the air that passes through it to ignite and produce the relatively harmless carbon dioxide (CO2). The life of the self-rescuer depends upon the length of time moisture is kept out of the hopcalite ; for this reason the canister is kept in its air-tight sealed case until it is used. Next to the hopcalite is another filter of cotton between wire screens. The last screen has a cross crimped into it diagonally from corner to corner, so that a space for the passage of air is provided between the filter and the tin-plate back of the canister. The air then passes through a mica-disc check valve to a passageway connecting to the mouthpiece. Exhaled air goes through the same passageway and through an exhale valve (mica-disc check valve) at the end of the self-rescuer opposite the mouthpiece. To prevent any carbon monoxide from leaking through the exhale valve and being breathed by the wearer, the mica disc seats against a knife-edge ring that is finished by careful grinding. A small spiral spring keeps the disc in continual contact with its seat when the pressure is low or is reversed, as when the wearer inhales.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Forbes, J. J.    U.S. Bureau of Mines  
Katz, S. H.    U.S. Bureau of Mines  


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print