Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

22nd September 1928, Page: 70, Column: 1

Electricity In Mines

By E. L. Martheleur.

[At the annual meeting in June of the Mining Society of Nova Scotia, Mr. E. L. Martheleur, the chief electrical engineer of the British Empire Steel Corporation, had for the subject of his paper "Electricity in Coal Mines." Extending to some fifty pages of the Bulletin of the Canadian Institute of Mining and Metallurgy, the paper dealt with the question particularly with reference to the Nova Scotia regulations. An excerpt is appended.]

The use of electricity in coal mines dates almost from the time when it was realised that it could be used to produce mechanical power. The first motor put in service underground was installed to drive a small pump nearly 40 years ago, and since then the use of electricity in mines has reached an extent undreamed of at that time. We now find its universal adoption in all the mining countries of the world. Great progress has been made in the development of mining electrical apparatus in the last decade, and excellent and adequate material is now available for the use of electricity underground. Although mining accidents, due to the use of electricity, are not frequent, the miner is justified in demanding that all electrical apparatus for installation below ground be constructed with a greater degree of safety than that used on the surface. That this view is shared by the authorities of the different mining countries is evidenced by governmental regulations relative to the use, erection, and maintenance of electrical apparatus below ground.

The potential dangers of electricity in coal mines are : Shock or burns by contact with live parts. Shock or burns by contact with parts which, although normally dead, have become accidentally alive. Fire. Explosion of gas or coal dust. Explosion of apparatus.

Shocks. — To prevent accidental contact with live parts it is now general practice to cover all these parts with metal maintained at earth potential by efficient grounding. Metal-clad switchgear is in universal use in collieries and it is significant that designs prepared and developed for difficult service in mines have been accepted in good practice as good standards for other industrial purposes.

Metals which are normally dead may become charged by accidental contact with live parts, and it is important to maintain the insulation of these live parts in an efficient state and to provide adequate spaces between live and dead metal. Electric cables must be left with sufficient slack to allow for strata movement, and they must be adequately supported. The armouring of such cable must be firmly secured to the various apparatus to which they connect, to take any external forces to which the table may be subjected ; and all dead metal, such as armouring of cable, frame of motor, and casing of apparatus, must be kept at earth potential by connection to earth plates and by maintaining continuity and high conductivity of the grounding system.

Fire. — The second source of danger from the use of electricity in mines is fire. This may be caused by failure of insulation, by overheating of conductors, or by electric discharge igniting oil in switches or in transformers. Even a small fire is extremely serious in a mine. Air which ventilates the colliery may be quickly mixed with fumes to such an extent that persons may be asphyxiated in a very short time.

To minimise the risk of fire, attention should be given to the rating of cable, motors and all apparatus carrying current, and provision should be made to disconnect any part of the plant which is dangerously overloaded or in which leakage to ground has taken place. All apparatus containing oil should be of sufficient strength to resist the effect of an explosion within it (or release safely the gas produced by such explosion). The oil and mechanism under oil should be frequently inspected and properly maintained. It is important that non-inflammable material be used in the construction of rooms containing electrical apparatus ; oil, waste, and inflammable material should not be allowed to accumulate at places where electricity is used ; cable and apparatus should be protected against mechanical damage and located in places where such damage is least likely to occur.

Ignition of Gas or Coal Dust. — At this date the use of electricity in places where gas is normally present is not permitted, but there are many places where gas, although not normally present, may accumulate whenever the ventilation is not perfect. Air containing a certain percentage of mine gas is very susceptible to explosion by electric sparking and the use of flame-proof enclosures is compulsory at every place where gas may be present in sufficient quantity to be a source of danger. A perfect flame-proof apparatus is easily rendered defective through carelessness. The omission of a bolt, a dirty or damaged flange, or failure to secure covers properly, defeat completely the flame-proof qualities of an apparatus. It should be noted, also, that an apparatus flame-proof at or below its normal rating may lose its effectiveness when overloaded or where the ventilation is insufficient to ensure the proper cooling of this apparatus.

Explosion of Switchgear. — The kind of explosion here referred to is the explosion of a mixture of air and oil-vapour in the oil containers of apparatus such as oil circuit breakers and transformers. If the oil is heated through overloading or lack of ventilation, it vapourises and forms with the air above the oil level an explosive mixture easily ignited by subsequent arcing. If the design of the tank is not such as to afford sufficient strength to resist an internal explosion, or to permit a rapid relief of the pressure created by such explosion, persons may be injured by projected metal, spraying of the ignited oil, or a resultant dangerous fire. An explosive mixture is formed in circuit breakers by sustained arcing between the contacts or when tripping under heavy overloads. It is important that these conditions be avoided as much as possible by having tanks of suitable design, strong enough to resist internal explosion, and by frequent inspection of the mechanism operated under oil.

It may be in order to explain what is meant by flame- and explosion-proof apparatus. The term explosion-proof means, I believe, that the container of an apparatus is made strong enough to resist an internal explosion, and the term flame-proof means that the apparatus cannot pass any flame or gas into surrounding atmosphere hot enough to ignite gas or coal dust when an explosion of the maximum force takes place inside of the container.

To be considered as safe, an apparatus does not need to be enclosed in a container having sufficient strength to withstand an explosion of the maximum force if this container is fitted with devices to relieve safely and rapidly any abnormal pressure within. It is out of the scope of this study to describe these safety devices ; they are based on the principle of cooling down the hot gases produced by an explosion to such a temperature that they could not ignite an explosive surrounding atmosphere. The usual method is to provide the tanks with flanges 1½ to 2 inches wide and to keep these flanges separated by .02 to to .01 of an inch. Sometimes rough machined faces to flanged joints, leaving a slight transverse grooving, is sufficient; sometimes small distance pieces, .02 inch thick, are riveted to the top flange to maintain the proper distance between the flanges ; in some devices machined flanges are brought in close contact by means of relief bolts whose function is to allow the cover to lift .02 inch to release safely the excess pressure in ease of internal explosion. When the container is not of great capacity, the different parts are bolted rigidly together without gaskets and calculated to withstand a pressure of 150 to 200 lb. per square inch.

Danger, however, is not the only point to be considered in selecting electrical material for use in coal mines. There are other points of importance, among which may be enumerated the following :—

All apparatus should conform with the regulations for the use of electricity in coal mines. These regulations may sometimes appear drastic to coal-mine operators, but the increment of safety against danger to person and property repays for the slight increase in capital incurred in the purchase of approved apparatus.

Electrical apparatus below ground, being installed and worked in remote locations, seldom if ever receives the same care and attention as equipment operated on the surface. In fact it is often abused.

Installations underground are always of a more or less temporary nature. As the mine develops and the work progresses, motor and switch-gears are transferred from one place to another; as a consequence, a minimum of care is given to the installation and to the proper housing of this material.

The surrounding atmosphere is often damp, sometimes dusty, or may contain inflammable gas or coal dust in sufficient proportion to be a source of danger. The equipment should be designed to meet all these adverse conditions.

The dimensions in the clear of mine roadways are often very restricted, and the outside dimensions of the various parts of an equipment are specially designed to suit these conditions. Mining motors are generally long and of small diameter ; mining transformers are reduced to minimum height and mounted on special trucks with flanged rollers to suit track gauge for easy transportation.

For some applications the question of efficiency and power factor is secondary to securing rugged and reliable motors ; this applies particularly where the demand is intermittent and the service arduous.

Electrical apparatus below ground is often operated by inexperienced hands, often abused, and should be made as fool-proof as possible, yet free from any unnecessary complications.

All apparatus underground should be mechanically protected against mechanical damage of all kinds.

These considerations and others not mentioned show how the conditions underground differ from those obtaining on the surface, and explain why general-purpose apparatus, however excellent it may be for factory or other industrial works, is totally unfit for iniiung service.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Martheleur, E. L.    Chief Electrical Engineer  


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print