Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

2nd June 1928, Page: 354, Column: 2

Gas Masks In Mines*

By Richard White, M.M., Assoc.I.M.E.

The gas mask does not supply the oxygen needed to maintain life, it serves only as a filter for removing relatively small proportions of irrespirable gas from air containing oxygen. Carbon monoxide gas masks, such as the Burrell All Service Gas Mask, protect against asphyxiating gases, vapours, and smokes not exceeding concentrations of 2 to 3 per cent. in air. This includes protection in mines in all atmospheres where a flame safety-lamp burns during fires or following explosions.

Self-contained breathing dress and helmets are heavy and to some extent clumsy pieces of apparatus, and it is necessary for the wearer to undergo a thorough course of training before he can be safely entrusted to wear the apparatus in service underground.

I had about two years' experience with the All Service Gas Mask, a description of the type used being as follows : The face piece is of the Kopps-Tissot type, which forms a pocket over the face and allows the wearer to breathe through his nose or to speak. Exhaled air passes out through a flutter-valve ; on inhaling, dry air enters through two tubes discharging over the eye-glasses, the dry air preventing fogging. The canister is supported by a harness of cotton webbing hung from the neck and kept against the chest by a strap around the body. Air enters the canister through a check valve at the bottom and leaves at the top through a "timer" which records the amount of usage. The "timer" is actuated by the inhalations, which causes a luminous hand to revolve around a dial. A revolution takes place in about two hours. Air is conducted from the "timer" to the "face-piece" through a rubber tube corrugated to increase flexibility and prevent collapse.

The canister contains granular absorbents (8 to 14 mesh size) arranged from bottom to top as follows:—

Activated charcoal impregnated with copper sulphate (quantity 660 c.c.); Pumice stone impregnated with anhydrous calcium chloride (85 c.c.) ; Fused calcium chloride (300 c.c.) ; Hopcalite (330 c.c.); Fused calcium chloride (160 c.c.). Between the charcoal and impregnated pumice is a filter of absorbent cotton ¼-inch thick for filtering smokes, dusts and mists. A similar filter is placed at the top. The activated charcoal removes from the air passing through it all poisonous gases excepting carbon monoxide (CO) and ammonia (NH3). The copper sulphate added to the charcoal enables it to remove ammonia gas by forming the complex copper ammonium sulphate. The fused calcium chloride removes water vapour which would destroy the action of the hopcalite if allowed to penetrate it. The pumice impregnation at the bottom prevents caking which would cause excessive resistance to breathing. Hopcalite is a mixture of prepared basis copper carbonate and manganese dioxide in granular form. It acts as a catalyst inducing CO in the air passing through to unite with the O2 therein, forming the relatively harmless CO2.

The process is one of combustion accelerated at low temperature by the hopcalite. The hopcalite itself undergoes no change and remains active until water vapour attacks it and gradually destroys the catalytic action. The life of the hopcalite thus depends upon the capacity of the calcium chloride to restrain water vapour. Canisters should be changed when the hand on the "timer" dial completes a revolution, because the hopcalite becomes vitiated when the canister is used, regardless o£ whether CO has been present or not. Water-vapour is always present in air, and it is this which determines the life of the hopcalite. The two-hour time limit allows a considerable factor of safety. Failure of the canister is gradual, so that the wearer has time to escape to fresh air before dangerous quantities of gas pass through.

The evidence accumulating seems to show that danger of insufficient oxygen in mines following explosions is sometimes small compared with the danger of carbon monoxide. In many of the American mines Self-Rescuers, or Half-hour sets, are carried by the miner to his working place. At a mine where I had experience in using the All Service Mask, we had many fires to contend with underground. The system we had was briefly as follows :—

At the Rescue Station at the mine head there were 6 Proto oxygen sets, also 6 Gibbs oxygen sets, with charging equipment; 40 All Service Gas Masks, canaries, flame safety-lamps and other equipment with trained attendants always on duty. With a good signalling system any dangerous occurrence was promptly tackled, the first examination being carried out by the men with oxygen sets. After the fresh air base was decided upon, all other work at the danger zone was done by men using the gas masks. Frequently, to find the exact location of the fire required much dangerous work, such as travelling over falls or where the use of these gas masks was almost indispensable.

Conclusions. — Investigators have observed during the study of these gas masks that many men who worked without respiratory protection were overcome, and that more frequent use of carbon monoxide gas masks should eliminate many such occurrences. Knowledge of the limitations of the mask as regards low oxygen atmospheres and the necessity of always keeping a flame safety-lamp at hand is important. Failure of the mask is gradual; should the wearer have difficulty in breathing, he should retire at once to the base. If these factors are always remembered, it seems that there is little danger of wearers of the carbon monoxide gas masks being overcome. The gas mask has actually effected a large saving of property, and has aided in quickly restoring mines after fires and explosions to normal working conditions ; it has also been instrumental in the saving of life.

* Excerpts from paper on "The Use of Carbon Monoxide Gas Masks in Mines," prepared for presentation on 12th May, at meeting of the Associates and Students' section of the North of England Institute of Mining and Mechanical Engineers.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
White, Richard      


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print