Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

21st April 1928, Page: 312, Column: 2

Coal Mine Ventilation*

By H. I. Smith.

Booster and Auxiliary Fans.

The technical and safety Press have devoted much space in support of or in opposition to the use of booster and auxiliary fans in coal mines. An auxiliary fan is a fan installed to divert a part of the air-current passing a given point for the purpose of ventilating some particular place or places, while allowing the remainder of the air-current to pass by.

The fundamentals of mine ventilation on which I think there is general agreement are as follows :—

(1) Booster fans will re-circulate air if there are any leaky stoppings, overcasts or doors between the intake and return airways on the suction side of the fan or if there is loose construction in the fan housing.

(2) Where air is re-circulated there is an undesirable decrease in the percentage of oxygen and an increase in the percentage of methane in the ventilating current. The former reduces the amount of work which men and animals can perform, and the latter is a hazard to the lives of the men in the mine.

(3) Auxiliary fans will re-circulate air when the volume of air passing through the entry is not in excess of that passing through the auxiliary fan, and they may re-circulate air when the current is in excess of that passing through the fan. Auxiliary fans will always re-circulate air when the fan is inbye the last open crosscut.

(4) Booster and auxiliary fans are not desirable as regards either economical operation or safety when used to offset the defects of leaky stoppings and doors, or as a substitute for properly maintained air-courses.

(5) Booster and auxiliary fans driven by electricity have ignited gas and have caused mine fires and gas explosions, resulting in loss of life and property.

(6) In the event of a mine fire, a booster fan may interfere seriously with or may aid in getting the fire under control,

(7) Wherever ventilation is dependent upon a booster fan if at the time of an explosion the fan cannot be operated by reason of being wrecked or the power being cut off, it seriously retards the recovery of the mine and greatly adds to the hazards of the rescue crew and of any survivors of the explosion.

The points on which there may be differences of opinion are :—

(1) Whether booster fans and auxiliary fans can be so placed and equipped with explosion-proof motors that there will be no danger of gas ignition by the motor or by static electricity from the belt or fan.

(2) Whether storage battery power, compressed air, or some form of power other than line electricity can be used safely.

(3) Whether booster fans can be so protected that the possibility of mine fires is eliminated.

(4) Whether underground fans can be so equipped as to be proof against conditions that might interfere with continuous operation to the same degree as outside fans.

(5) Whether the use of automatic starters on underground fans can be considered a safe practice.

(6) Whether the same protective devices can be applied to underground fans that are required by law on surface fans, such as offsetting the fan from the line of an explosion force, the use of explosion-relief doors and of a recording pressure gauge, and in case of stoppage or slowing down the flashing of a light or sounding of a gong at some point where there is a constant attendant, as in the engine room.

Booster fans in coal mines in the United States are, in my opinion, a direct hazard and too often a sign of weakness in the system of ventilation. This weakness may be due to a change in plans whereby a mining operation may be extended several times the distance originally contemplated, without the retention of sufficient pillars in which the additional entries required for proper ventilation may be driven, or it may be due to a day-to-day method of mining in which the aim is to keep down the daily cost regardless of future air requirements.

The use of auxiliary fans may be inspired by false economy, by operating plans which increase distances between breakthrough, or by a failure of the ventilating system from leaky stoppings and clogged air-courses. My observations have been that the responsibility for the installation of booster fans and in many mines of auxiliary fans lies in leaky doors, stoppings, and overcasts ; in the use of too many doors in lieu of overcasts and the substitution of canvas, board or gob for concrete stoppings in crosscuts ; and in restricted air-courses and air-courses closed or partly closed by falls of roof or by heaving bottom. The cost of correcting these conditions may be greater than the cost of installing a booster fan, but loss of mine safety incurred by failure to correct them is too high a price to pay.

Booster fans may also be installed on the initiative of the company or on instructions from the mine inspector to increase the amount of air or where an increase in air circulation is so urgent that time will not permit the cleaning of the air-courses and the building of tight stoppings. Where air splits are of unequal length booster fans may be installed on the split of the greater resistance in lieu of building up the resistance on the shorter split by means of a regulator.

Another condition which is rare in the United States but may occur in Nova Scotia and Great Britain is that of coal so thin and air-courses so long that with tight stoppings and clean air-courses the resistance is so great that the air cannot be forced through in sufficient quantities at ordinary pressure to keep the oxygen above 20 per cent. and the percentage of methane below an amount that can be detected with a miner's safety-lamp. Under such circumstances the driving of additional entries or the enlargement of the air-courses by brushing the roof will greatly extend the time before the installation of booster fans must be considered. The additional entries should be driven and the roof brushed as the entries advance, rather than waiting until the demand is acute and the cost of doing all the work at one time looks prohibitive.

It is freely admitted that the ventilation of coal mines should be continuous except during necessary fan repairs and that, should the fans be stopped even for only a short period, all employees should be withdrawn from the mine. Outside fans for ventilating coal mines are equipped with many commendable devices to give a warning by light or sound when the fan speed or air pressure has been reduced below a prescribed minimum. Devices are used to give warning when the bearings of the fan reach a certain temperature. Surface fans are offset from the line of a possible explosion and are equipped with explosion-relief doors.

If recording and safety devices of the type mentioned are of value on outside fans they are even more essential on underground fans. To date, however, I have failed to observe any underground fan offset so as to prevent its injury in the event of an explosion, although G. S. Rice has shown me a sketch of such an arrangement at a mine in Nova Scotia. Unless underground fans are continuously operated and are equipped with the same warning and safety devices as outside fans, they should be condemned as vigorously as one would condemn a surface fan under such circumstances.

Records indicate that by reason of intermittent operation, booster fans have moved bodies of gas to some distant point, where they have been ignited. This hazard is greater than that involved in practice, universally condemned, of moving gas by brushing with a coat, shovel or water spray. It is apparent that in places containing small amounts of methane at the face the methane percentage gradually increases after the air-current is cut off, and even after the current is re-established there is a continued increase in methane at the face for a period of time. In view of this continued increase and the fact that methane may be moved in an explosive body for long distances from the point where it may accumulate, the use of automatic starters on underground fans is decidedly dangerous. Intermittent supervision of underground fans is likewise dangerous.

Twelve years ago my attention was first drawn to re-circulation. I made a test on a booster fan and found that in the return there was but 13,000 cubic feet of air while at the booster fan there was 29,250 cubic feet. Measurements were then made of the air on the haulage entry opposite the fan, showing 29,200 cubic feet of air. The loss of 16,200 cubic feet of air occurred within a distance of 2,000 feet and indicated approximately 500 cubic feet per stopping and door. There was more than 0.5 per cent. of methane in the air. In my report attention was called to the possibility of igniting the gas by static electricity, even though a protected motor may have been used to drive the fan. The static electricity is credited with accumulating on the blades of a booster fan driven by compressed air.

A small fan set on the surface at a certain coal mine was used to ventilate a shaft before underground connections had been made to the air shaft. The shaft was divided by a wooden partition, and as it was found that the air-current was too sluggish to keep the mine clear of methane a second or booster fan was set at the bottom of the shaft to increase the circulation. The additional fan did not help much in ridding the development entries of gas, and after checking up carefully with an anemometer it was found that although some 10,000 cu. ft. of air was being handled by the first fan and a similar amount by the fan at the shaft bottom there was no movement half-way down the shaft, or at least insufficient movement to turn the anemometer. Investigation showed that the air handled by the top fan was leaking out before it reached the bottom of the shaft and that the air handled by the bottom fan was being pulled through the brattice boards and re-circulated. The use of a large canvas tubing connected directly to the top fan resulted in providing more fresh air than the top and booster fan combined had been furnishing, and accordingly the booster fan was eliminated.

If consulting mining engineers were called on more generally to solve ventilating problems the cost of many booster and auxiliary fans, as well as many surface fans, would be saved, and better ventilation would result.

To illustrate an acute danger in the use of booster fans, I would quote Daniel Harrington, who observed a case where workers receiving air passing through a canvas tubing had difficulty in keeping their carbide lights burning. Matches would not burn at the fan, yet 50 feet outside the fan a match would burn brightly, thus indicating the extent to which the booster fan failed to draw on fresh air but 50 feet away. Mr. Harrington has also shown me a long list of fires and explosions resulting from booster fans, including one where an ordinary office fan used to clear entries of gas resulted in casualties and others involving longwall mining where men have been burned by the ignition of gas at the fan motor.

There are places such as in underground pump stations, hoist rooms and electrical stations where the use of auxiliary fans and canvas tubing in place of line brattices appears to be appropriate, temporarily at least, but power is always uncertain at the face, and when a fan stops even for a short time there is no way in which the main fan can take care of the gas accumulations. In some mines the power goes off so often that a fireboss cannot withdraw all the men and make an examination every time it happens. When the main fan stops, the men, including those at the face as well as those at the shaft bottom, are withdrawn, and it is of course particularly important to withdraw those in the more dangerous parts of the mine should there be any interruption of the ventilation from any cause.

One way to eliminate the dangers of booster and auxiliary fans is to eliminate the necessity for them by getting a large percentage of the air from the main fan to the face with a minimum of power. This can be done in a number of ways, such as sinking shafts in advance territory, or erecting all stoppings and overcasts of concrete and eliminating doors. I was instrumental in bringing about the adoption, in several mines opened up in Indiana in 1917 and 1918, of a plan having in view more economical ventilation. This plan provides for two pairs of main entries with a solid pillar of coal between the two pairs. One pair is used for intake air and one pair for return air ; the solid pillar is to be cut only at the cross entries. The same scheme has been more recently followed in large mining operations in Illinois.

The demand for auxiliary fans or blowers can also be greatly reduced by driving more entries, building more concrete stoppings, and using fewer doors. The aim in ventilation should be to get to the last crosscut 90 per cent. of the fresh air handled by the surface fan, or nine times the amount to be found in some mines.

Before any surface, booster, or auxiliary fans are installed in or at a coal mine, fan houses and airways should be examined and it should be found out whether the appropriation should be made for a fan or for changes in the mine. If there is not a ventilation man in the organisation, advice should certainly be bought from a consulting engineer familiar with up-to-date coal mining ventilation who can point out the spots in the mine that are below par.

* From paper read before the American Institute of Mining and Metallurgical Engineers.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Harrington, Daniel      
Rice, G. S.    U.S. Bureau of Mines  
Smith, H. I.      


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print