21st April 1928, Page: 305, Column: 1
Mine Ventilation
At one of the sessions in connection with the annual gathering of the American
Institute of Mining and Metallurgical Engineers, as announced in "Mining
and Metallurgy," the paper by H. P. Greenwald and H. C. Howarth
was read by the senior author, its title being "Recirculation
of Air and Mine Gas Caused by Auxiliary Fans as Used in Coal Mines." The
data presented were extremely interesting and aroused considerable discussion.
Mr. Greenwald stated that the tests were by no means complete, but that
certain conclusions could be drawn that will promote safety in auxiliary-fan
installations. These conclusions, without reference to dangers from
accumulation of gas or the hazard of gas ignition by electric motors, are: (1)
An auxiliary fan should always be installed on the fresh-air side of the place
to be ventilated, and the fan inlet should not be less than 8 feet from the
nearer rib of the place ventilated or of the last cut-through, as the case may
be. (2) When so placed the fan should take no more than 40 per cent. of the
air-current in which it is placed. (3) If the distance from the fan to the
nearer corner be increased to, say, 16 feet, the danger of recirculation is
decreased. (4) It is not practical to place a fan so that it may take the
entire current in which it is placed. (5) The use of a check brattice to aid in
avoiding re-circulation is only justified in emergency. (6) When two fans are
operated side by side, their inlets should be not less than 8 feet from the
nearer rib of the cut-through, and their combined delivery should be not more
than 40 per cent. of the air current in which they are placed.
 |
 |
|