10th March 1928, Page: 272, Column: 2
Combustion Of Coal
In the course of a paper on Pulverised Coal for Collieries and Industrial
Plants, before the South Staffs. and Warwickshire Institute of Mining
Engineers, Mr. J. Burns said that when combustion takes place there are
two distinct stages. The coal is first raised to such a temperature that the
volatile hydrocarbons are driven off and combine with the oxygen of the air to
form CO2 and H20. In the second stage the carbon is
raised to such a temperature that it burns, combining with oxygen to form
CO2. This is correct theoretically, provided there is sufficient
oxygen present; but otherwise the combustion is incomplete, CO is formed
instead of CO2, and much of the available heat is lost. On the other
hand, with the ordinary methods of firing there is always a considerable
percentage of excess air, partly necessary to reduce the furnace temperature
and prevent undue damage to the refractory lining, but mostly unnecessary and
wasteful. From another point of view excess air is necessary with large masses
of coal on a mechanical stoker, as it is obvious that the rate of combustion
depends on the velocity of the air stream through the bed of coal. The
necessary oxygen can only be brought into intimate contact with the coal
surfaces by a scrubbing action of the air. A large proportion of the air will
even then not come into actual contact with the combustion surface, and
although it is true that a fair proportion of this air ultimately combines with
the volatile part of the fuel, the conditions are such that there is a large
percentage of excess air. Variations of load make it impossible to adjust the
excess air to a uniform figure. With pulverised-fuel firing the air supply is
subject to easy regulation so that the fuel and the air are admitted to the
combustion chamber in the correct mixture for perfect combustion, and at the
lowest possible velocity. The velocity with which the air meets the fuel does
not affect the rate of combustion, as this depends almost wholly on the size of
the coal particles, together with the size of the combustion chamber and the
burners. A proportion of the air required may be employed to carry the
pulverised coal into the chamber, the bulk being added through controlled ports
or through an opening surrounding the burner. The fuel is thus distributed
throughout the whole volume of the combustion chamber, and, the supply of air
being under close control, it is possible to maintain a high efficiency through
a wide range of output, and an average CO2 content in the flue gases
of at least 15 per cent. An actual test for normal output up to 300 per cent.
overload gave a CO2 variation of 1 per cent.
 |
 |
|
Names mentioned in this article
|
 |
 |
| Name | Age | Occupation | Notes |
| Burns, J. | | Mining Engineer | |