Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

25th February 1928, Page: 247, Column: 2

Miner's Electric Gas-Detecting Lamp

In the course of the paper he had prepared on "A New Gas-measuring Miner's Electric Lamp," for presentation at the meeting of the North of England Institute of Mining and Mechanical Engineers, on the 18th of February, Dr. W. M. Thornton, O.B.E., D.Sc, D.Eng., recalled the guiding rules laid down by Dr. Beiling, Director of the German Mines Department Testing Station at Derne, that a gas-measuring device should give its final measurements in 30 seconds at most, that it should be capable of being fitted to any make of lamp without interfering with its function as a source of light, be simple to understand and handle, robust, unaffected materially by dust, and have certain features of mechanical strength and ease of operation. Dr. Thornton came to the conclusion that for measurement of the percentage of gas, as distinct from a mere indication of a fixed percentage of gas present, nothing could be quicker than some means of comparing the brightness of two electrically-heated filaments, one in the gas and the other enclosed from contact with it, the added brightness in the former case being due to nameless combustion of the inflammable gas on the surface of the wire. It occurred to him that if, instead of attempting to compare the brightness of a filament glowing in gas with a fixed standard, one could vary a source of light to equal that of the filament and make the means of variation provide a measure of the gas present, the problem might be solved. The special feature of his device is that the variable source for comparison is the working filament of the illuminating lamp itself.

In carrying this out, the heated spiral is, while testing for gas, connected in parallel with the lamp-filament across the battery terminals, and is enclosed in the same thick protecting cover-glass. The top of this glass is open, and, instead of being held close up against the metal top, as in the older forms of lamps, is separated from it by a space of about a quarter of an inch. The open top is covered with flat double gauzes held in position by an annular cap carrying a bridge which fits into the dished top of the hood-plate, fixing the whole firmly in place. Around the cap is a sleeve, which can be raised after testing to keep out dust, but which is lowered when testing for gas. It has been found, however, that blowing clouds of fine dust into the chamber does not materially affect the measurement of any gas present. In series with the filament is a resistance fixed into the battery contact plate. The rotation of the case varies the resistance in series with the lamp, which, in the working position for travelling or other purposes, is cut entirely out of circuit, the lamp having then its full brightness. When testing for gas the steps are : (1) lower the dust-cap ; (2) rotate the case until the lamp-filament and the heated spiral, which are placed close in line with one another for the purpose of comparison, are equally bright. A scale of percentages of gas, determined by calibration for any one make of lamp, but once fixed, true for all lamps of that type, is attached either to the glass or on the case, and as the possible angular movement is in some cases nearly a complete circle, the scale may be as open as desired. Having referred to some effects, Dr. Thornton summed up the advantages of the lamp as follows :— (1) It provides a simple and accurate method of measuring inflammable gas within a few seconds. (2) The range of operation, i.e., from ½ to 8 per cent. or more, is much greater than is possible with oil lamps. (3) The light is never lost as with an oil-lamp. (4) The lamp is not affected by blows or by sudden changes in air-pressure. (5) The electric parts are robust, and the heater, if broken, is as easily replaced as a lamp-bulb.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Beiling, —, Dr.      
Thornton, William Mundell, Dr.      Whos Who Page


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print