Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

11th February 1928, Page: 228, Column: 2

Colliery Cable's History

By W. T. Anderson, M.I.E.E.

[At the January meeting of the Past and Present Mining Students' Association, held in the Wigan Mining and Technical College, Mr. W. T. Anderson, M.I.E.E., traced the history of a colliery cable, under the caption, "From Factory to Face." In the course of the lecture many interesting views were thrown on the screen. Some extracts from the lecture are appended.]

Cable manufacture may be considered to begin at the point where copper wire is received in the form known as "Commercial Rod." This consists of coils of soft drawn metal weighing about two cwts. each, varying in thickness from ¼ inch to 3/8 inch and coated with a heavy oxide, which gives it an appearance not unlike that of wrought iron. These coils are first subjected to a cleansing process by pickling in dilute sulphuric acid, which dissolves away the scale of oxide and incidentally, on concentration of the used liquor, yields as a valuable by-product the blue crystalline copper sulphate. The cleansed coils of copper — of a purity (according to Matthieson's Standard of 98 per cent.) are then ready for drawing to gauge ; the coarser sizes are drawn through hard steel dies and the finer through perforated diamonds. The process of drawing hardens the wire, and consequently the next step is to pass it through an annealing furnace where it is softened by exposure to a temperature of 450 degrees Cent. The wires must be soft and pliant before they can be stranded up. Prior to stranding, however, wire which is not intended for use with fibrous dielectrics is thoroughly tinned in order to avoid deleterious action between the copper and the rubber or bitumen insulations.

In connection with the insulation covering the stranded cores' it may be remarked generally that dielectrics of impregnated paper are lapped round the cores, bitumen dielectrics are squeezed or forced on, and rubber dielectrics sometimes lapped on and sometimes squeezed on, the last named process being completed by welding the covering into a homogeneous whole in the process of vulcanising.

For mining purposes most of the above types are metallically enclosed. On paper cables this generally takes the form in the first instance of a seamless cylindrical sheath of lead put on by hydraulic gear (working at a pressure on the ram of 13 tons to the square inch) ; on rubber cables with lead or armour or both ; on bitumen cables with steel wire armour only, laid on in one or two layers so as to give the enclosing metallic sheath, under the Mines Department Regulations, on all multicore cables working above low pressure (defined as 250 volts), an effective conductivity of 50 per cent. of the largest conductor enclosed. In no case, however, must any earth shield or bond have a less sectional area, irrespective of the metal used, than 0.022 of a square inch. For underground use double wire armouring is infinitely to be preferred to single wire armouring, on account not only of its greater flexibility but its much greater resistance to tortional stresses.

Paper lead covered cables are tested both hydraulically (that is under a pressure of some 100 lb. to the square inch) and electrically. Bitumen and rubber cables are tested electrically in their taped state, prior to armouring, an effective earth being provided by immersion in large water tanks provided for the purpose. On completion of armouring, the cables are further protected with a braiding or lapping of tarred jute, being ultimately finished off with a thorough impregnation of bituminous compound.

Paper lead covered cable has advantages as regards withstanding heat from without, and ready dissipation of heat, consequent upon overload, from within, but it has the disadvantage common to all fibrous materials of being more or less hygroscopic. In the event of the lead sheath being punctured or fractured by mechanical damage, entrance of moisture not only leads to breakdown at the point of damage, but to a dangerous absorption of water, which is difficult to eradicate entirely, and which will probably lead to further trouble in other parts of the cable to which it may penetrate. Indeed, it is hardly conceivable that in a wet shaft a cable of this construction could be got out before moisture had ruined a very considerable portion of its length. Further, lead is particularly vulnerable to electrolytic attack and it can readily be imagined that perforation from this cause would very speedily put a set of feeders out of commission. There are other dangers, happily infrequent, which come to paper cables from quite unexpected quarters — in some cases the gnawing of rats has caused considerable damage. Many theories have been advanced as to the possible attraction which actuates a rodent to attack a cable. One may safely surmise that suicide from lead poisoning can be disregarded as the creature usually survives this stage. A theory widely accepted is that nature compels a rat to gnaw at practically anything in order to regulate the rapid growth of its front teeth. The writer, however, is inclined to think it may partially be due to an extraordinarily keen sense of smell (lead, be it remembered, being crystalline in structure) which enables the animal to trace and try to get access to, the impregnating oils with which the paper dielectric is saturated.

To overcome the electrolytic difficulty a third type of cable, known as paper leadless, is sometimes used. It is a sort of halfway house between a paper lead covered and a bitumen cable, a sheath of the latter material taking the place of the lead. This type, though more suitable than solid bitumen for very high pressures, possesses the disadvantages of the lead covered material from the moisture point of view.

Bitumen, speaking generally, is undoubtedly the most effective dielectric for mining purposes. Until quite recently great difficulty was experienced in getting the bitumen insulation to such a consistency that in moderately high temperatures it would not decentralise, while in low temperatures it would not become brittle. As the result of research and of manufacturing improvements, it is now possible to avoid these troubles over a range of temperature which covers all ordinary working conditions, say 28 to 120 degrees Fahr. It is usual to fill up the strands of this type of cable solid, so that, should moisture enter, gravity and capillary attraction can play little part in an extension of the trouble.

Modern collieries usually take power in bulk from a Public Supply Company, generate electric power with exhaust steam from their own winders, or, not infrequently, burn their low grade surplus fuel which it is difficult or impossible to sell. It becomes obvious, therefore, that inter-connection between a group of pits under one management often becomes highly desirable. When considerable distances nave to be covered this is generally effected by means of bare overhead lines at high pressures. The connection between cable and overhead line is usually made by means of an inverted joint box, fixed just under the aerial line level on a terminal pole or on the generating station wall.

Faults on overhead work are usually easy both to detect and to repair though unprotected lines suffer some obvious disadvantages from which cables are immune. The results of lightning, for instance, are usually severe though seldom widespread. It should be noted that though distance is the primary factor in designing mains for electric transmission, environment plays no inconsiderable part. For short distances, especially in the immediate vicinity of a colliery, various methods are available. Taking first the cases of feeders laid in the ground :—

Perhaps the most common is that known as "laying solid" where the cables are run on asphalt bridge pieces laid in iron, asphaltic, or wooden troughing, made up solid with bitumen and covered with a tile or similar cover.

"Laying direct" is also a method frequently resorted to, and consists of the dropping into the ground of an armoured feeder with no protection other than a warning board or a row of bricks to cover it. The cable is laid by hand, horse, or locomotive as circumstances demand. Great care has to be exercised in laying direct as the nature of the ground is an important factor in its effect on the life of a cable. "Made" or "Carbonised" ground, or the presence of peat and decaying vegetable matter, which is likely to set up galvanic or chemical attack, must be scrupulously avoided. In such cases a padding of puddle or clay becomes necessary to protect the feeders.

Waterlogged ground, somewhat of a bogey, can generally be got over by patience, pumps and common sense. Steam laden soil is another matter, and an extremely prolific cause of failure in surface cables. Obvious ways adopted to overcome this difficulty have been the construction of an open-air trench and the running along walls or gantries where such are available. By far the most satisfactory method, however, is the suspension of a cable by means of braided lead slings from a catenary wire, which if well anchored, will support enormous weights and along which a cable can be drawn.

Coming to the pit-head, to which the surface cable is now assumed to have been made off. Shaft lengths of cable are lowered in a variety of ways, the drums being brought as near the pit mouth as possible and jacked into suitable positions for paying off. Unlike a steel cable, an electric cable should not be subjected to any mechanical stresses which can reasonably be avoided or damage to the insulation is likely to result. For this reason the most satisfactory method is to attach the cable to a winding or haulage rope by means of hemp lashings spaced at intervals of about 15 feet. Should time be an important factor two or three such lashings can be made simultaneously by rigging up scaffolding in the shaft. All stresses are thus borne by the wire hawser, which is lowered, by signal, from a stationary engine. Besides very powerful braking tackle a plank brake is advisable on the drum itself. This is not to hold the load but simply to prevent over-running. With light cables, lowering from within or from under the cage is sometimes feasible, though great care is necessary to avoid the weight of the contingent loop running away with the drum.

The question of permanent suspension in the shaft is the next consideration. In a "tubbed" shaft, where an iron lining has been rendered necessary from the presence of quicksand or other cause, the use of a single suspender is often obligatory. The arrangement is, however, very undesirable. The only suitable fitting is of the cone type which involves a quadrupling of the armour at the top of the cable, and although the fitting itself could readily be made to carry the weight of a house if necessary, it is not advisable to allow more than 50 cwts. to be borne in this matter. At the Hulton disaster, where a large portion of the upcast head-gear was blown away, the clamp suspenders in commission survived the ordeal. They certainly carried paper cables, which it has been held in some quarters demonstrated their fitness for mining work. If a cable is initially constructed for such conditions the contention is correct.

In cases of great depth it is obviously impossible to install a shaft feeder in one section. The best method of dealing with such a case is to install a horizontal box (where the incoming and outgoing feeders enter at the same end), an inset either provided or existing. The cleanness of this method, as compared with the use of an ordinary straight through box, is obvious. Similarly, cases also arise where a number of seams or separate mines are tapped from the same shaft. If no reduction in cable size is involved a disconnecting box of somewhat similar design to the last can be employed — but in the case of any reduction the law rightly compels the introduction of some form of protective gear in the shape of fuses or the like. This entails a switch pillar, or a series of them constituting a substation, which, whether placed in an inset, in the distributing centre at the pit bottom, or in a haulage house in-bye, must be of the totally enclosed ironclad type. These pillars are usually made in four compartments, one for sealing the cable and bonding the armour, the second for protective gear, the third for quick break switches capable of instantly isolating any portion of the mine, and the fourth for common or inter-connecting bus-bars.

The life of a cable largely depends on the efficiency of the sealing chamber, the functions of which are to keep moisture out of the cable, eliminate surface leakage, and also provide the bond or connection with the armour by means of which any stray or sudden rush of current is conveyed to bank and discharged in the general mass of earth by means of plates or, in a manner standardised by the writer and now largely adopted, by means of partially buried pipes.

Roadway cables are generally run out in drum lengths and jointed on shelves or on brick pillars midway between floor and roof. The cables usually terminate in a "gate end" box, so named from its position at the entrance to the "gate roads" which splay out, octopus like, to various points at the coal face.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Anderson, W. T.      


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print