Cable manufacture may be considered to begin at the point where copper wire is
received in the form known as "Commercial Rod." This consists of
coils of soft drawn metal weighing about two cwts. each, varying in thickness
from ¼ inch to 3/8 inch and coated with a heavy oxide, which gives it an
appearance not unlike that of wrought iron. These coils are first subjected to
a cleansing process by pickling in dilute sulphuric acid, which dissolves away
the scale of oxide and incidentally, on concentration of the used liquor,
yields as a valuable by-product the blue crystalline copper sulphate. The
cleansed coils of copper — of a purity (according to Matthieson's
Standard of 98 per cent.) are then ready for drawing to gauge ; the coarser
sizes are drawn through hard steel dies and the finer through perforated
diamonds. The process of drawing hardens the wire, and consequently the next
step is to pass it through an annealing furnace where it is softened by
exposure to a temperature of 450 degrees Cent. The wires must be soft and
pliant before they can be stranded up. Prior to stranding, however, wire which
is not intended for use with fibrous dielectrics is thoroughly tinned in order
to avoid deleterious action between the copper and the rubber or bitumen
insulations.
In connection with the insulation covering the stranded cores' it may be
remarked generally that dielectrics of impregnated paper are lapped round the
cores, bitumen dielectrics are squeezed or forced on, and rubber dielectrics
sometimes lapped on and sometimes squeezed on, the last named process being
completed by welding the covering into a homogeneous whole in the process of
vulcanising.
For mining purposes most of the above types are metallically enclosed. On paper
cables this generally takes the form in the first instance of a seamless
cylindrical sheath of lead put on by hydraulic gear (working at a pressure on
the ram of 13 tons to the square inch) ; on rubber cables with lead or armour
or both ; on bitumen cables with steel wire armour only, laid on in one or two
layers so as to give the enclosing metallic sheath, under the Mines Department
Regulations, on all multicore cables working above low pressure (defined as 250
volts), an effective conductivity of 50 per cent. of the largest conductor
enclosed. In no case, however, must any earth shield or bond have a less
sectional area, irrespective of the metal used, than 0.022 of a square inch.
For underground use double wire armouring is infinitely to be preferred to
single wire armouring, on account not only of its greater flexibility but its
much greater resistance to tortional stresses.
Paper lead covered cables are tested both hydraulically (that is under a
pressure of some 100 lb. to the square inch) and electrically. Bitumen and
rubber cables are tested electrically in their taped state, prior to armouring,
an effective earth being provided by immersion in large water tanks provided
for the purpose. On completion of armouring, the cables are further protected
with a braiding or lapping of tarred jute, being ultimately finished off with a
thorough impregnation of bituminous compound.
Paper lead covered cable has advantages as regards withstanding heat from
without, and ready dissipation of heat, consequent upon overload, from within,
but it has the disadvantage common to all fibrous materials of being more or
less hygroscopic. In the event of the lead sheath being punctured or fractured
by mechanical damage, entrance of moisture not only leads to breakdown at the
point of damage, but to a dangerous absorption of water, which is difficult to
eradicate entirely, and which will probably lead to further trouble in other
parts of the cable to which it may penetrate. Indeed, it is hardly conceivable
that in a wet shaft a cable of this construction could be got out before
moisture had ruined a very considerable portion of its length. Further, lead is
particularly vulnerable to electrolytic attack and it can readily be imagined
that perforation from this cause would very speedily put a set of feeders out
of commission. There are other dangers, happily infrequent, which come to paper
cables from quite unexpected quarters — in some cases the gnawing of rats
has caused considerable damage. Many theories have been advanced as to the
possible attraction which actuates a rodent to attack a cable. One may safely
surmise that suicide from lead poisoning can be disregarded as the creature
usually survives this stage. A theory widely accepted is that nature compels a
rat to gnaw at practically anything in order to regulate the rapid growth of
its front teeth. The writer, however, is inclined to think it may partially be
due to an extraordinarily keen sense of smell (lead, be it remembered, being
crystalline in structure) which enables the animal to trace and try to get
access to, the impregnating oils with which the paper dielectric is saturated.
To overcome the electrolytic difficulty a third type of cable, known as paper
leadless, is sometimes used. It is a sort of halfway house between a paper lead
covered and a bitumen cable, a sheath of the latter material taking the place
of the lead. This type, though more suitable than solid bitumen for very high
pressures, possesses the disadvantages of the lead covered material from the
moisture point of view.
Bitumen, speaking generally, is undoubtedly the most effective dielectric for
mining purposes. Until quite recently great difficulty was experienced in
getting the bitumen insulation to such a consistency that in moderately high
temperatures it would not decentralise, while in low temperatures it would not
become brittle. As the result of research and of manufacturing improvements, it
is now possible to avoid these troubles over a range of temperature which
covers all ordinary working conditions, say 28 to 120 degrees Fahr. It is usual
to fill up the strands of this type of cable solid, so that, should moisture
enter, gravity and capillary attraction can play little part in an extension of
the trouble.
Modern collieries usually take power in bulk from a Public Supply Company,
generate electric power with exhaust steam from their own winders, or, not
infrequently, burn their low grade surplus fuel which it is difficult or
impossible to sell. It becomes obvious, therefore, that inter-connection
between a group of pits under one management often becomes highly desirable.
When considerable distances nave to be covered this is generally effected by
means of bare overhead lines at high pressures. The connection between cable
and overhead line is usually made by means of an inverted joint box, fixed just
under the aerial line level on a terminal pole or on the generating station
wall.
Faults on overhead work are usually easy both to detect and to repair though
unprotected lines suffer some obvious disadvantages from which cables are
immune. The results of lightning, for instance, are usually severe though
seldom widespread. It should be noted that though distance is the primary
factor in designing mains for electric transmission, environment plays no
inconsiderable part. For short distances, especially in the immediate vicinity
of a colliery, various methods are available. Taking first the cases of feeders
laid in the ground :—
Perhaps the most common is that known as "laying solid" where the
cables are run on asphalt bridge pieces laid in iron, asphaltic, or wooden
troughing, made up solid with bitumen and covered with a tile or similar cover.
"Laying direct" is also a method frequently resorted to, and consists
of the dropping into the ground of an armoured feeder with no protection other
than a warning board or a row of bricks to cover it. The cable is laid by hand,
horse, or locomotive as circumstances demand. Great care has to be exercised in
laying direct as the nature of the ground is an important factor in its effect
on the life of a cable. "Made" or "Carbonised" ground, or
the presence of peat and decaying vegetable matter, which is likely to set up
galvanic or chemical attack, must be scrupulously avoided. In such cases a
padding of puddle or clay becomes necessary to protect the feeders.
Waterlogged ground, somewhat of a bogey, can generally be got over by patience,
pumps and common sense. Steam laden soil is another matter, and an extremely
prolific cause of failure in surface cables. Obvious ways adopted to overcome
this difficulty have been the construction of an open-air trench and the
running along walls or gantries where such are available. By far the most
satisfactory method, however, is the suspension of a cable by means of braided
lead slings from a catenary wire, which if well anchored, will support enormous
weights and along which a cable can be drawn.
Coming to the pit-head, to which the surface cable is now assumed to have been
made off. Shaft lengths of cable are lowered in a variety of ways, the drums
being brought as near the pit mouth as possible and jacked into suitable
positions for paying off. Unlike a steel cable, an electric cable should not be
subjected to any mechanical stresses which can reasonably be avoided or damage
to the insulation is likely to result. For this reason the most satisfactory
method is to attach the cable to a winding or haulage rope by means of hemp
lashings spaced at intervals of about 15 feet. Should time be an important
factor two or three such lashings can be made simultaneously by rigging up
scaffolding in the shaft. All stresses are thus borne by the wire hawser, which
is lowered, by signal, from a stationary engine. Besides very powerful braking
tackle a plank brake is advisable on the drum itself. This is not to hold the
load but simply to prevent over-running. With light cables, lowering from
within or from under the cage is sometimes feasible, though great care is
necessary to avoid the weight of the contingent loop running away with the
drum.
The question of permanent suspension in the shaft is the next consideration. In
a "tubbed" shaft, where an iron lining has been rendered necessary
from the presence of quicksand or other cause, the use of a single suspender is
often obligatory. The arrangement is, however, very undesirable. The only
suitable fitting is of the cone type which involves a quadrupling of the armour
at the top of the cable, and although the fitting itself could readily be made
to carry the weight of a house if necessary, it is not advisable to allow more
than 50 cwts. to be borne in this matter. At the Hulton disaster, where a large
portion of the upcast head-gear was blown away, the clamp suspenders in
commission survived the ordeal. They certainly carried paper cables, which it
has been held in some quarters demonstrated their fitness for mining work. If a
cable is initially constructed for such conditions the contention is correct.
In cases of great depth it is obviously impossible to install a shaft feeder in
one section. The best method of dealing with such a case is to install a
horizontal box (where the incoming and outgoing feeders enter at the same end),
an inset either provided or existing. The cleanness of this method, as compared
with the use of an ordinary straight through box, is obvious. Similarly, cases
also arise where a number of seams or separate mines are tapped from the same
shaft. If no reduction in cable size is involved a disconnecting box of
somewhat similar design to the last can be employed — but in the case of
any reduction the law rightly compels the introduction of some form of
protective gear in the shape of fuses or the like. This entails a switch
pillar, or a series of them constituting a substation, which, whether placed in
an inset, in the distributing centre at the pit bottom, or in a haulage house
in-bye, must be of the totally enclosed ironclad type. These pillars are
usually made in four compartments, one for sealing the cable and bonding the
armour, the second for protective gear, the third for quick break switches
capable of instantly isolating any portion of the mine, and the fourth for
common or inter-connecting bus-bars.
The life of a cable largely depends on the efficiency of the sealing chamber,
the functions of which are to keep moisture out of the cable, eliminate surface
leakage, and also provide the bond or connection with the armour by means of
which any stray or sudden rush of current is conveyed to bank and discharged in
the general mass of earth by means of plates or, in a manner standardised by
the writer and now largely adopted, by means of partially buried pipes.
Roadway cables are generally run out in drum lengths and jointed on shelves or
on brick pillars midway between floor and roof. The cables usually terminate in
a "gate end" box, so named from its position at the entrance to the
"gate roads" which splay out, octopus like, to various points at the
coal face.
 |
 |
|