Logo Museum
Museum
Friends of Durham Mining Museum
Events Calendar
e-Books and Books for sale
Photograph Gallery
Document Archive
Main Document Archive
Newspaper Articles
Articles by date
Articles by colliery
Personal name index
Local Record Extracts
D.M.A. Document Archive
Transactions of I.M.E.
Miners' Welfare
N.C.B. Archive
The Colliery Engineer
The Colliery Guardian
Mine & Quarry Engineering
Mining Journal
The Science and Art of Mining
Coal Magazine
Coal News
Coke and Gas
Master Name Index
What's new in the site
Mining
Mining History
Colliery Index
Colliery Maps
Company Overviews
Who's Who
Mineral Information
Managers Certificates
Educational Material
Bibliography
Statistics
Workers/Employee Lists
Notes for Family Historians
War Service information
Disasters
Disaster Reports
Names of those killed
Disasters in the 1700s
Disasters in the 1800s
Disasters in the 1900s
Memorials
Awards for Gallantry
On this day ...

Links to other sites of interest
Industrial Heritage Days Out
Former www.pitwork.net web site

Index to site

Contact and address details

Share Page with Social Media

Share on Facebook

Share with Reddit

Share on Delicious


 Newspaper Articles Index Newspaper Articles 

5th November 1927, Page: 124, Column: 1

Compressed Air In Cool Mines*

By Marc Piard.

In a cool mine, tapping high-pressure lines through reducing valves lowers the temperature beyond remedy. It is the writer's suggestion that, for low-pressure work, low-pressure air should be generated in a compressor installed underground adjacent to the work, and that the jacket-water of the compressor should be utilised for re-heating purposes. Such a system of compressed air distribution, designed especially for service in cool mines, is described in the following notes.

The suggested system includes a three-wire pole line from the sub-station to the opening nearest to the working face, with a cable connection extending to the latter from the openings ; an electrical centrifugal unit; a reservoir excavated in the ground ; and a distribution line, re-heated by jacket-water. As regards the reservoir, it may be pointed out that in many mines there are blind or abandoned tunnels that could be used for the purpose.

The centrifugal type of compressed air machine is a comparatively new departure, and it was formerly considered that such a machine, operating at less than 1,000 kilowatts per unit, would be commercially impracticable. At the present time, however, these machines are being built in Europe for as little as 400 kilowatts per unit, and as much as 110 lb. per square inch pressure.

One advantage which these centrifugal machines have over other types is that they may be driven by plain induction motors, without the help of special starters — a consideration of the first importance where the electrical regulations are severe.

A compressor which is to operate a hoist and several conveyors, loading machines, and air picks, will require as much as 400 kilowatts ; and yet such a machine is so compact — the overall size approximates only 10 by 5 by 5 feet — that it can be easily moved from point to point, as the working face progresses or retreats.

In a mine whose air and ground temperatures are respectively 40 deg. F. and 50 deg. F., the air engines work at 25 deg. F., this being the practical minimum quoted by the makers. In the reservoir, then, the air is cooled to a minimum temperature of 50 deg. F. (the ground temperature), and in the process of cooling it loses part of its moisture. The actual amount of moisture thus lost will depend on the size of the reservoir. The larger this is, the drier will the air become, and at the same time the peaks that the comparatively small plant is able to take care of will be correspondingly higher.

The level section of the distribution is re-heated by jacket-water in a trough. As some of the connections are exposed to the cool mine atmosphere, the temperature of this re-heated air may be as low as 70 deg. F. when it reaches the engines.

Compared with this, the air from a reducing valve on a high-pressure line would reach the engine with a temperature not exceeding 40 deg. F. — a difference, in favour of the low-pressure system, of at least 30 degrees.

The relative performance of the two systems at the point of use can be estimated both for full-pressure work and for expansion work. The full-pressure work for a given weight of air at a given pressure is proportional to the absolute temperature of the air. For the high-pressure and low-pressure lines, absolute temperatures would be 530 deg. and 500 deg. respectively, showing an economy, in favour of the latter, of 6 per cent. on full-pressure work alone. On expansion work, the advantage would be much greater.

When re-heating is negligible at the point of use, the mechanical energy given out by expansion is equal and opposite in sign, to the loss of internal energy in the expanded fluid, i.e., under such conditions there is, irrespective of pressure, a constant output of mechanical energy equivalent to the constant internal loss of 0.1689 B.T.U. per lb. of air per deg. F.

The drop in temperature for the air tapped by reducing valves is 15 degrees. The proposed drop of 45 degrees being three times as great, the expansion work also would be three times as great — or an economy of 66 per cent.

This result is borne out by a test made by the writer 14 years ago in a cool Alberta mine. Comparison of the performance of locomotives working expansively in this mine, where the atmosphere had a temperature of 40 deg. F., with that of similar locomotives in a European mine, where the average temperature in the haulage road was 70 deg. F., showed that the ratio of air consumption per ton mile in the two mines was nearly 3:1.

It follows from this that, in a district where one-half of the air power is used expansively, the general economy at the point of use alone would approximate 40 per cent.

Air picks working expansively are desirable, but to give the required blow they would have to be unduly bulky. Air engines on hoisting, conveying, and loading machinery are designed for partial expansion.

The system here proposed would be particularly advantageous in electrified mines in which the compressed air requirements at working faces far from the sub-station are subject to rapid change, since, in addition to the economy at the point of use (as explained above), it would result in a large saving due to the transmission being electrical instead of pneumatic. Electrical transmission over a distance of two miles should have an efficiency of at least 90 per cent.

As a result of having large reserves of compressed air stored in the ground, the practically uniform supply of alternative current will find a steady average load, and machinery which is used intermittently will not have to work on irregular fluctuating pressure, or be compelled to stand idle while waiting for pressure. Storage of energy is thus provided at low cost, even in comparison with electrical energy.

It has not been considered necessary in this paper to stress the advantages of re-heating. These are fully set forth in the textbooks. It will be sufficient to state that heat, as a booster df compressed air, has an industrial efficiency of 80 per cent., which is twice the efficiency of the best types of internal combustion engines.

The use of compressed air in mines is growing very rapidly, with the introduction of a great variety of mechanical tools and machines which are proving of great aid to the miner. Its increased employment in the coal-mining industry is to be commended and encouraged, not only on the score of economy but also in order that eventually it may entirely displace the use of explosives and other poisonous substances in the mining of coal.

* From Transactions of the Canadian Institute of Mining and Metallurgy and of the Mining Society of Nova Scotia. Read at RocKy Mountain Branch Meeting.


Names mentioned in this article

 

 Name  Age  Occupation  Notes 
Piard, Marc      


 

mail
Mail:
Webmaster
Back
Back
Home
Home
Open Government Licence   Contains public sector information licensed under the Open Government Licence v3.0.

Copyright © 1999-2024 by The Durham Mining Museum and its contributors
Registered Charity No: 1110608
Page last updated: 28 Nov 2022

Privacy Policy
 
Terms & Conditions
 
Search
Search
Print
Print