|
8th October 1927, Page: 88, Column: 2 Ignition Of Gases By Hot WiresIt is known that inflammable gases can sometimes be ignited by a heated wire. A research described in the Safety in Mines Research Board Paper No. 36 ("The Ignition of Gases by Hot Wires," by W. C. P. Shepherd and R. V. Wheeler, H.M. Stationery Office, price 1s.), was undertaken to discover to what extent the glowing tungsten filament of a 2-volt miners' electric lamp-bulb might constitute a source of danger in a coal mine by reason of its possible ability to cause the ignition of mixtures of firedamp and air. As a corollary to this research, when it was found that the ignition of firedamp in this manner was a likely danger, experiments were made with straight wires of platinum and tungsten to determine whether it was possible so to proportion the filaments of 2-volt lamp-bulbs that they could not cause the ignition of firedamp. It was found that if a platinum wire were less than 0.1 mm. in diameter it would always fuse when an electric current was passed through it without causing the ignition of firedamp. With fine tungsten wires, on the other hand, the metal burnt rapidly in air, giving a small flame which always ignited firedamp. It would therefore seem a wise precaution to incorporate in the design of a miner's electric hand-lamp an automatic device to break the electric circuit as soon as the outer protecting glass is broken. In their summary and conclusions the authors say :— Mixtures of methane and air can readily be ignited by wires of platinum or tungsten of suitable dimensions when they are heated by the passage through them of an electric current. With platinum wire of a given diameter, ignition can only occur within a narrow range of currents. Below this range, nameless surface combustion alone takes place ; and above it, the wire fuses without igniting the mixture. Judged by the value for the minimum igniting-current, all mixtures of methane and air are equally readily ignitable by platinum wires. When a platinum wire is surrounded by an inflammable mixture, its temperature is raised on the passage of an electric current to a value greater than that attained when air surrounds it, by reason of the heat generated during flameless combustion on the surface of the wire. The mixture near to the wire becomes heated and convection currents are set up. Ignition only takes place if the mixture remains in contact with the hot wire for a time longer than the "lag" on ignition. The effect of convection is greatest with mixtures having the highest calorific value (9.45 per cent. methane), so that these remain in contact with the hot wire for the briefest times and are less easily ignitable than mixtures of lower calorific value. The thicker the wire, the lower is the temperature to which it must be heated to cause ignition of a methane-air mixture. When a heated tungsten wire is exposed to an atmosphere containing oxygen, it is oxidised and its temperature increases until it burns with a bright flame of short duration, but very high temperature. Ignition of an inflammable mixture surrounding a heated tungsten wire is effected, not by the hot wire itself, but by the flame produced when the wire burns. The phenomena are therefore those of ignition by momentary flames, and the most readily ignitable mixtures of methane and air contain about 8 per cent. of methane.
|
|||||||||||||||||||
![]() |
||||||||
|
Mail: Webmaster |
Back |
Home |
Copyright © 1999-2024 by The Durham Mining Museum and its contributors Registered Charity No: 1110608 Page last updated: 28 Nov 2022
|
Search |
|
|||